• 제목/요약/키워드: flux optimization

검색결과 263건 처리시간 0.029초

유도형 변위 센서의 민감도 향상을 위한 형상 최적 설계 (Shape Design Optimization of Inductive Position Sensor to Improve Sensitivity)

  • 홍준희;이동주;신우철
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.250-254
    • /
    • 2001
  • The resolution of analog sensor is determined by its sensitivity and amplitude of noise. This paper presents modeling of inductive gap sensor base on equivalent magnetic circuit and analysis of sensitivity. We can simulate static characteristic of inductive gap sensor using this model. Computer simulation show that sensor's sensitivity is affected by magnetic flux's leakage and fringing, and that they are affected by shape of sensor probe. Base on this, we designed shape of inductive position sensor probe.

  • PDF

축방향 자속 이중 여자 방식의 이중 고정자를 갖는 릴럭턴스 기기의 회전자 설계 (Axial Flux Dual Stator Doubly Fed Reluctance Machine Rotor design)

  • 살만 칼리크;;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.669-670
    • /
    • 2015
  • In this paper, rotor design modification of a novel proposed machine termed the Axial Flux Doubly Fed Reluctance Machine (AF-BDFRM) is studied. The main potential advantage of AF-BDFRM is that it has larger torque and power density compared to radial flux-BDFRM. However, with the general rotor pole shape, this machine output back EMF has high THD % and high cogging torque. This paper studies the rotor design modification in the proposed AF-BDFRM to reduce the THD % in inducedd back EMF and cogging torque. Also the transient 3D finite element analysis (FEA) optimization of initial design is presented.

  • PDF

Optimal Design of a Distributed Winding Type Axial Flux Permanent Magnet Synchronous Generator

  • You, Yong-Min;Lin, Hai;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.69-74
    • /
    • 2012
  • This paper presents a distributed winding type axial flux permanent magnet synchronous generator (AFPMSG) with reduced the total harmonic distortion (THD), suitable for wind turbine generation systems. Although the THD of the proposed distributed winding type is more reduced than the concentrated winding type, the unbalance of the phase back EMF occurs. To improve the unbalance of the phase back EMF and the output power of the distributed winding type AFPMSG, the Kriging based on the latin hypercube sampling (LHS) is utilized. Finally, these optimization results are confirmed by experimental results. As a result, the unbalance of the phase back EMF and the output power of the distributed winding type AFPMSG were improved while maintaining the total harmonic distortion (THD) and the average phase back EMF.

Reduction of Torque Ripple in an Axial Flux Generator Using Arc Shaped Trapezoidal Magnets in an Asymmetric Overhang Configuration

  • Ikram, Junaid;Khan, Nasrullah;Khaliq, Salman;Kwon, Byung-il
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.577-585
    • /
    • 2016
  • In this paper, model of the axial-flux permanent magnet synchronous generator (AFPMSG) having arc-shaped trapezoidal permanent magnets (PM) is presented. The proposed model reduces the cogging torque and torque ripple, at the expense of lowering the average output torque. Optimization of the proposed model is performed by considering the asymmetric overhang configuration of the PMs, as to make the output torque of the proposed model competitive with the conventional model. The time stepped 3D finite element analysis (FEA) is performed for the comparative analysis. It is demonstrated that the torque ripple of the optimized model is highly reduced as well as average output torque is increased.

Phenol removal by tailor-made polyamide-fly ash composite membrane: Modeling and optimization

  • Vandana, Gupta;Anandkumar, J.
    • Membrane and Water Treatment
    • /
    • 제10권6호
    • /
    • pp.431-440
    • /
    • 2019
  • A novel composite membrane was synthesized using crosslinked polyamide and fly ash ceramic substrate for phenol removal. Glutaraldehyde was used as crosslinker. Characterization shows that synthesized membrane possesses good permeability ($0.184l.m^{-2}.h^{-1}.kPa^{-1}$), MWCO (1.7 kDa), average pore size (1.08 nm) and good chemical stability. RSM was adopted for phenol removal studies. Box-Behnken-Design using quadratic model was chosen for three operating parameters (feed phenol concentration, pH and applied pressure) against two responses (phenol removal, flux). ANOVA shows that model is statistically valid with high coefficient of determination ($R^2$)value for flux (0.9897) and phenol removal (0.9302). The optimum conditions are obtained as pH 2, $46mg.l^{-1}$ (feed phenol concentration) and 483 kPa (applied pressure) with 92.3% phenol removal and $9.2l.m^{-2}.h^{-1}$ flux. Data validation with deviation of 4% confirms the suitability of model. Obtained results reveal that prepared composite membrane can efficiently separate phenol from aqueous solution.

Optimization of target, moderator, and collimator in the accelerator-based boron neutron capture therapy system: A Monte Carlo study

  • Cheon, Bo-Wi;Yoo, Dohyeon;Park, Hyojun;Lee, Hyun Cheol;Shin, Wook-Geun;Choi, Hyun Joon;Hong, Bong Hwan;Chung, Heejun;Min, Chul Hee
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1970-1978
    • /
    • 2021
  • The aim of this study was to optimize the target, moderator, and collimator (TMC) in a neutron beam generator for the accelerator-based BNCT (A-BNCT) system. The optimization employed the Monte Carlo Neutron and Photon (MCNP) simulation. The optimal geometry for the target was decided as the one with the highest neutron flux among nominates, which were called as angled, rib, and tube in this study. The moderator was optimized in terms of consisting material to produce appropriate neutron energy distribution for the treatment. The optimization of the collimator, which wrapped around the target, was carried out by deciding the material to effectively prevent the leakage radiations. As results, characteristic of the neutron beam from the optimized TMC was compared to the recommendation by the International Atomic Energy Agent (IAEA). The tube type target showed the highest neutron flux among nominates. The optimal material for the moderator and collimator were combination of Fluental (Al203+AlF3) with 60Ni filter and lead, respectively. The optimized TMC satisfied the IAEA recommendations such as the minimum production rate of epithermal neutrons from thermal neutrons: that was 2.5 times higher. The results can be used as source terms for shielding designs of treatment rooms.

해안지하수개발 최적화수치모델과 해석해의 비교연구 (Comparison of a Groundwater Simulation-Optimization Numerical Model with the Analytical Solutions)

  • 시뢰;최뢰;이찬종;박남식
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.905-908
    • /
    • 2009
  • In the management of groundwater in coastal areas, saltwater intrusion associated with extensive groundwater pumping, is an important problem. The groundwater optimization model is an advanced method to study the aquifer and decide the optimal pumping rates or optimal well locations. Cheng and Park gave the analytical solutions to the optimization problems basing on Strack's analytical solution. However, the analytical solutions have some limitations of the property of aquifer, boundary conditions, and so on. A simulation-optimization numerical method presented in this study can deal with non-homogenous aquifers and various complex boundary conditions. This simulation-optimization model includes the sharp interface solution which solves the same governing equation with Strack's analytical solution, therefore, the freshwater head and saltwater thickness should be in the same conditions, that can lead to the comparable results in optimal pumping rates and optimal well locations for both of the solutions. It is noticed that the analytical solutions can only be applied on the infinite domain aquifer, while it is impossible to get a numerical model with infinite domain. To compare the numerical model with the analytical solutions, calculation of the equivalent boundary flux was planted into the numerical model so that the numerical model can have the same conditions in steady state with analytical solutions.

  • PDF

자기장의 균일성을 고려한 자기공명장치의 최적설계 (Optimal Design of an MRI Device Considering the Homogeneity of the Magnetic Field)

  • 이정훈;유정훈
    • 대한기계학회논문집A
    • /
    • 제32권8호
    • /
    • pp.654-659
    • /
    • 2008
  • This paper is to suggest a concept design of the permanent magnet type magnetic resonance imaging (MRI) device based on the parameter optimization method. Pulse currents in the gradient coils will introduce the effect of eddy currents in the ferromagnetic material, which will worsen the quality of imaging. In order to equalize the magnetic flux in the MRI device for good imaging, the eddy current effect in the ferromagnetic material must be taken into account. This study attempts to use the design of experiment (DOE) and the response surface method (RSM) for equalizing the magnetic flux of the permanent magnet type MRI device using that the magnetic flux can be calculated directly using a commercial finite element analysis package. As a result, optimal shapes of the pole and the yoke of the PM type MRI device can be obtained. The commercial package, ANSYS, is used for analyzing the magnetic field problem and obtaining the resultant magnetic flux.