• Title/Summary/Keyword: fluoride application

Search Result 249, Processing Time 0.025 seconds

Application of PVDF to Enhance Drainage Capability in Clay Slurry (점토슬러리의 배수촉진을 위한 PVDF의 활용)

  • Kim, Young-Uk;Park, Ji-Ho;Lam, Hoang Trong;Kim, Jung-Han;Jung, Dong-Hwan;Kim, Sang-Shik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.871-873
    • /
    • 2009
  • 기존의 연직 배수공법은 통수능의 저하, 막힘현상(clogging) 등으로 인하여 연약지반의 압밀을 지연시키는 문제점을 가지고 있다. 이 연구에서는 고분자 압전소자인 PVDF(polyvinylidene fluoride)를 연직배수공법에 적용하여 연직배수공법의 기존 문제점을 극복하고 연약지반의 간극수를 빠르게 소산시킴으로서 압밀을 촉진 시킬 수 있을 것이라 판단되어 이에 따른 실내 실험을 수행하였다. 실험 결과 PVDF를 적용한 경우에서 그렇지 않은 경우보다 간극수의 배출량이 증가하여 PVDF의 적용으로 배수재의 성능이 향상됨을 알 수 있었다.

  • PDF

A STUDY ON PIEZOELECTRIC PROPERTIES OF PVDF AND ITS COPOLYMERS

  • Ansari, Mohd.Zahid;Cho, Chong-Du
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.584-589
    • /
    • 2007
  • Polyvinylidene fluoride (PVDF) is a type of electroactive polymer which shows significant shape change when exposed to electric field. PVDF is generally used as a film sensor in non-destructive evaluation (NDE) of materials. In this study, however, its properties relevant to film actuator are considered. Since most of the electromechanical applications that use PVDF and its copolymers as actuators use their piezoelectric properties, only the piezoelectric properties of PVDF are discussed here. These properties depend mainly on the degree of crystallinity of PVDF. Available data from recent research publications are used to simulate the response of a PVDF bimorph beam on the application of electric field, by a commercial finite element analysis package ANSYS. Finally, the factors that affect mechanical behavior of PVDF bimorph beam are discussed.

  • PDF

PVDF interdigitated transducer for generating and detecting Lamb waves in plates

  • Gu, Hua;Lloyd, George M.;Wang, Ming L.
    • Smart Structures and Systems
    • /
    • v.4 no.3
    • /
    • pp.291-304
    • /
    • 2008
  • Piezoelectric materials have been widely used in ultrasonic nondestructive testing (NDT). PZT ceramics can be used to receive and generate surface acoustic waves. It is a common application to attach PZT transducers to the surface of structures for detecting cracks in nondestructive testing. However, not until recently have piezoelectric polymers attracted more and more attention to be the material for interdigitated (IDT) surface and guided-wave transducers. In this paper, an interdigitated gold-on-polyvinylidene fluoride (PVDF) transducer for actuating and sensing Lamb waves has been introduced. A specific etching technology is employed for making the surface electrodes into a certain finger pattern, the spacings of which yield different single mode responses of Lamb waves. Experiments have been performed on steel and carbon fiber composite plates. Results from PVDF IDT sensors have been compared with those from PZT transducers for verification.

Electroluminescence Properties from Blend films of poly(3-hexylthiophene) and poly(N-vinylcarvazole) (P3HT와 PVK 블렌드 막에서의 전계 발광 특성)

  • Kim, Dae-Jung;Kim, Shang-Gi;Gu, Hal-Bon;Jung, Un-Jo;Park, Ge-Chun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.972-975
    • /
    • 2002
  • Electroluminescence(EL) devices based on organic thin layers have attracted lot of interests because of their application as display. One of the problems is red material. It offered a short life and poor emission efficiency to boot. In this study, this problem can be solved by using a multi-layer device structure. Organic electroluminescent devices which are composed of organic thin multi-layer films are fabricated. The basic structure is ITO / Emitting layer / LiP / Al EL device in which Hole transport/Electron blocking PVK layer was blending. We demonstrate the enhancement of eletroluminescence (EL) from blends of poly(3-hexylthiophene) in poly(N-vinylcarvazole). The emitting layer is consisted of a host material(PVK) and a guest emitting material(P3HT). It was showed higher EL intensity and their electro-optical properties were investigated.

  • PDF

A Study on Frequency Properties of Bulk Acoustic Wave Resonators using PVDF (고분자 압전필름을 이용한 BAW 공진기의 주팍수 특성에 관한 연구)

  • 정영학;김응권;윤창진;송준태
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1077-1079
    • /
    • 2003
  • This paper describes the development of bulk acoustic wave (BAW) resonators using a PolyVinyliDene Fluoride (PVDF). The resonators have an air gap between a substrate for acoustic isolation without surface micromachining. We measured the resonance frequency and the input reflection coefficient (S$\sub$11/) of resonators using vector network analyzer. The fundamental resonance in this experimental result was measured at 1.4 ㎓ with a return loss of -23.2 ㏈. We can confirm a possibility of resonator application as using a PVDF because it can fabricate the resonator without etching process.

A Study on Frequency Property of Bulk Acoustic Wave Resonator Using PVDF (고분자 압전필름을 이용한 Bulk Acoustic Wave Resonator의 주파수 특성에 관한 연구)

  • Jeong, Young-Hak;Kim, Eun-Kwon;Yun, Chang-Jin;Lee, Kyu-Ill;Lee, Jong-Duk;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.673-676
    • /
    • 2003
  • This paper describes the modeling and experimental results for Bulk Acoustic Wave(BAW) Resonator using PolyVinyliDene Fluoride(PVDF). We measured the input reflection coefficient ($S_{11}$) of resonators using vector network analyzer and experimental results were measured fundamental resonance at 2.3 GHz with a return loss of -29 dB. Because of fabricated resonator without etching process, we can confirm a possibility of resonator application as using a PVDF.

  • PDF

Magnetoelectric Polymer Composites (자기전기 고분자 복합체)

  • Ko, Kyujin;Noh, Byung-Il;Yang, Su-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.4
    • /
    • pp.229-241
    • /
    • 2021
  • Since 2010, polymer-based magnetoelectric (ME) composites have been developed with detailed investigations of multiferroic properties such as piezoelectric, magnetostrictive, and magnetoelectric, etc. In particular, as a piezoelectric polymer, poly(vinylidene fluoride) and its co-polymers have been widely used in ME composites for energy harvesting, health monitoring, environment treatment, and bio-medical applications. In this study, main research trend and selected experimental results of polymer-based ME composites are briefly reviewed with respect to composite structure as well as application field. A conclusion was drawn that the polymer-based ME composites would be feasible as flexible devices or functional membranes in the near future.

Bond strength of different bonding systems to the lingual surface enamel of mandibular incisors (하악 전치 설측면에 대한 다양한 접착시스템의 접착강도)

  • Turkoz, Cagri;Tuncer, Burcu Balos;Ulusoy, Mehmet Cagri;Tuncer, Cumhur
    • The korean journal of orthodontics
    • /
    • v.40 no.4
    • /
    • pp.260-266
    • /
    • 2010
  • Objective: The aim of this study was to determine whether different types of adhesive systems and enamel-protective agents will affect the tensile bond strength of lingual brackets. Methods: A total of 75 extracted mandibular incisors were randomly divided into 5 groups and lingual brackets were bonded. Group 1 specimens received Transbond XT (3M Unitek, Monrovia, CA, USA), Group 2 required the application of a fluoride-releasing resin (Ortho-coat, Pulpdent, Watertown, MA, USA) with Transbond XT, Group 3 specimens received a chlorhexidine varnish (Cervitec Plus, Ivoclar Vivadent, Schaan, Lichtenstein) with Transbond XT. In Group 4, a light-cured orthodontic adhesive (Aegis Ortho, Bosworth, Skokie, USA) was applied and in Group 5, an antimicrobial self-etching primer (Clearfil Protect Bond, Kuraray, Osaka, Japan) was used. Results: There were no significant differences in bond strength whether fluoride-releasing resin or chlorhexidine varnish were used or not. Group 5 had significantly higher bond strength and adhesive remnant index (ARI) values than other groups (p < 0.001). The application of enamel-protective products did not have an adverse affect on the bond strength of lingual brackets. Conclusions: These products might provide benefits both for the patient and the clinician, by supporting the oral hygiene during lingual orthodontic treatment. The higher ARI score may be beneficial for Clearfil Protect Bond but its excessive bond strength should be considered in clinical practice, especially where the enamel is thin.

Analysis of Occupational Disease Caused by Oral Health Behavior of Some Dental Hygiene Students (일부 치위생과 학생의 구강건강행위와 구강병 발생요인 간의 관계)

  • Lim, Soon-Hwan;Hwang, Ji-Min
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.3
    • /
    • pp.256-264
    • /
    • 2018
  • The purpose of this study was to investigate the relationship between oral health behaviors and the results of the oral dysentery test for dental hygienists and students at Gyeonggi - do and Chungcheongnam - do. Self - filling questionnaires and oral diseases. The following conclusions were obtained. The most common toothbrushing frequency was three times a day (60.2%), and the most dominant frequency of eating between meals was once or less(49.7%). The most common snack that they had was stickiness-free sweetened food(66.5%), and the type of beverage that they had the most was sweetened beverages(49.7%). The average stimulated saliva flow rate was 9.41ml, and they got a mean of 9.52 in the buffering capacity of saliva. The average glucose clearance time was a mean of 12.02. When they took a streptococcus mutans colony count test, 80.1 percent belonged to the low-risk group(<$10^5$), and 82.6 percent belonged to the low-risk group(<$10^5$) when a lactobacillus test was conducted. There was a positive correlation between the irritant saliva fraction and the non-irritating saliva and saliva buffering ability. In the fluoride application experience, the glucose retention time was 10.66 minutes and the fluoride application experience was 13.33 minutes. (P = .008). The importance of oral health, which is directly linked to general health, should be emphasized in order to improve the quality of life as well as the life expectancy. For oral health, which is directly linked to systemic health, it is necessary to provide opportunities for oral health education that can be easily accessed by the public, and to continuously develop and provide oral health care programs for a lifetime.

CHANGES IN ADHESION OF STREPTOCOCCUS MUTANS TO NANOCOMPOSITE RESINS AFTER ACIDULATED PHOSPHATE FLUORIDE GEL APPLICATION (나노컴포지트에서 Acidulated Phosphate Fluoride 적용에 따른 Streptococcus mutans 부착량 변화)

  • Jung, Young-Jung;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.427-436
    • /
    • 2005
  • Topical application of APF gel can increase the surface roughness of resin composites and the roughened surfaces may allow increased bacterial accumulation and surface staining. Resin specimens of two proprietary resin composites, Filtek Z250(FZ) and Filtek Supreme Universal(FS), and experimental resin composites containing 0%, 3%, 6% nanofillers(E0, E3, E6) were fabricated and divided into two groups of the same number; APF treatment group and no treatment group. The amount of S. mutans adhered to specimens and the mean surface roughness(Ra) were measured. The results were as follows; 1. In no treatment group, the amount of S. mutans adhered to FS was the smallest. It was significantly different from those of FZ, E3, E6(p<0.05) although it was not significantly different from that of E0(p>0.05). 2. For all resin composites used, the amount of S. mutans adhesion in APF treatment group was significantly greater than that in no treatment group(p<0.05). 3. In APF treatment group, the amount of S. mutans adhesion was significantly different between materials(p<0.05), and increased in order of FS, FZ, E0, E3 and E6. 4. Difference of the surface roughness(Ra) between materials was not statistically significant in both no treatment group and APF treatment group(p>0.05)

  • PDF