• Title/Summary/Keyword: fluoride

Search Result 1,636, Processing Time 0.033 seconds

CHARACTERISTICS OF FLUORIDE RELEASING RESTORATIVE MATERIALS AFTER TOOTHBRUSH-DENTIFRICE ABRASION (잇솔질 마모 처리한 불소방출성 수복재의 특성)

  • Park, Jong-Ha;Baik, Byeong-Ju;Yang, Yeon-Mi;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.705-713
    • /
    • 2004
  • The objectives of this study were to evaluate the fluoride release and the change of surface roughness of fluoride releasing restorative materials after toothbrush-dentifrice abrasion. Seven commercially available fluoride releasing restorative materials (Fuji II LC Improved: FL, Compoglass F: CG, Dyract AP: DR, F2000: FT, Ariston: AT, Tetric: TR, and Gradia: GD) were selected as experimental materials. The results obtained were summarized as follows: 1. The AT, FL, and CF groups produce an initially large burst of fluoride release and comparatively low but continuous release of fluoride. But other groups produce no initial burst of fluoride and levels of release remain relatively constant. 2. The rate of fluoride release remains steady state after 40 days. The results of Tukey's test (P<.05), the fluoride release showed the order of decreasing rank as follows: AT > FL > compomers > TC and GD. 3. The surface roughness indicated that the highest value was observed in the FT group and the lowest value was observed in the CF group. The surface roughness of Tukey's test showed the significant differences between groups of FT, AT and FL and groups of CF, DR, GD and TC (P<0.05).

  • PDF

Correlation between Fluoride Release, Microhardness and Solubility of High viscosity Glass Ionomers (고점도 글라스아이오노머의 불소 유리량, 미세경도 및 용해도의 상관관계)

  • Shin, Bisol;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.418-425
    • /
    • 2018
  • This study was to measure and compare the amount of fluoride, microhardness and solubility of high viscosity glass ionomer and resin-reinforced glass ionomer during 84 days. Fuji IX GP EXTRA, Fuji IX GP, Fuji II LC and Filtek$^{TM}$ Z350XT stored in deionized water for 84 days to measure fluoride release, microhardness and solubility. As a result of measurement of fluoride release, all the glass ionomers showed the highest amount of fluoride release on day 1 and gradually decreased. Fuji IX GP EXTRA showed the highest amount of fluoride release and cumulative release. And Fuji IX GP and Fuji II LC showed no significant difference. Microhardness measurements showed that all experimental groups decreased 1 day after exposure to water. After 84 days, microhardness showed no significant difference between Fuji IX GP EXTRA and Fuji IX GP, and Fuji II LC was the lowest. In the solubility measurement, Fuji IX GP EXTRA, Fuji IX GP, and Fuji II LC increased rapidly to 21 days. After 21 days, there was no significant difference in the three groups. As a result, short term fluoride release affects solubility and microhardness, but long term fluoride release has no correlation. Through this study, the amount of fluoride, microhardness, and solubility of various glass ionomers were evaluated, and these properties could be applied clinically.

A COMPARISON OF THE SHEAR BOND STRENGTHS BETWEEN CONVENTIONAL COMPOSITE SEALANTS AND FLUORIDE-RELEASING SEALANTS (불소유리 전색재와 일반 레진계 전색재의 전단결합강도에 관한 비교연구)

  • Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.85-89
    • /
    • 2000
  • There has recently been some trials to add the fluoride-releasing property to existing fissure sealants and some of them are already commercially available. But, some questions mat naturally be arisen regarding the potential decrease of physical properties by adding the fluoride despite its new caries-inhibiting abilities. This study was performed for the purpose of comparing the shear bond strengths of conventional composite sealant, Fluoride-releasing sealant and glass ionomer sealant, and obtained the results as fellows. 1. Two kinds of composite sealants (Helioseal and Teethmate-A) showed slightly higher bond strength than Fluoride-releasing sealant(Teethmate-F) without any significance(p>0.05). 2. Class ionomer sealant (Fuji III) was much lower than composite sealant in shear bond strength(p<0.05). 3. With the result of this study, it was found that there is little effect on retentive properties of sealants by adding fluoride to amplify the caries-inhibiting properties.

  • PDF

The effect of fluoride and casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) pplication on the color and microhardness of bleached enamel (치아미백 후 불소와 CPP-ACP 처리가 치아의 색과 미세경도에 미치는 영향)

  • Shim, Youn-Soo;Choi, Woo-Yang
    • Journal of Korean society of Dental Hygiene
    • /
    • v.10 no.3
    • /
    • pp.473-481
    • /
    • 2010
  • Objectives : To evaluate the effect of fluoride application on the color and microhardness of bleached enamel and compare it to that of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) application. Methods : Twenty freshly extracted human adult molar were each sectioned into halves, the specimens divided and treated according to five experimental groups: Group 1, treatment with 10% carbamide peroxide (CP) bleaching agent; Group 2, treatment with 10% CP followed by a 1.23% fluoride gel application; Group 3, treatment with 10% CP followed by a 2.23% sodium fluoride varnish application; Group 4, treatment with 10% CP followed by a 0.11% sodium fluoride gel application; Group 5, treatment with 10% CP followed by a CPP-ACP gel application. All groups were treated 6 h per day for 14 days then immersed in distilled water for 2 weeks. Changes in enamel color were evaluated on Baseline and Day 14. Microhardness were evaluated on Baseline, Days 7 and 14. Statistical analysis was performed using one-way ANOVA and post-hoc Tukey tests. Results : All the bleached enamel specimens revealed increased whiteness and overall color value. Group 1 showed the lowest microhardness values than that of Groups 2, 3, 4 and 5. In all groups, the hardness of tooth after bleaching showed a significant decrease in the microhardness as compared with the one prior to tooth bleaching. The specimens treated with remineralizing agents showed relatively less reduction in enamel microhardness than control group. Conclusions : The addition of fluoride and CPP-ACP did not impede the whitening effect. The use of remineralizing agents during bleaching treatment can significantly enhance the microhardness of bleached enamel.

Fluoride Reduction of Antarctic Krill by Electrocondensation Method (Electrocondensation 방법에 의한 크릴 불소 감량)

  • Kim, Kil-Hwan;Kim, Dong-Man;Kim, Young-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.172-176
    • /
    • 1990
  • Electrocondensation method using aluminum electrodes was developed to remove excess amount of fluoride contained in Antarctic krill. Fluoride amount was reduced differently according to fluoride forms (total, ionic and bound) and sections (whole, muscle flesh and chitinous) of the Antarctic krill during electrocondensation process. Total, ionic and bound fluoride could be reduced by 56%, 35% and 60% of the initial amount contained in the whole body, respectively and reduced by 49%, 57% and 34% of the initial amount in the muscle flesh, respectively by electro condensation process for 120 min. In the case of chitinous section of the Antarctic krill, 68% of total fluoride could be decreased by this process for 120 min.

  • PDF

A Survey on the Contents of Fluoride, Calcium, and Magnesium of Reservoir Water on a Stream in the Jeon-buk Area of Korea (전북 지역 일부 수원지의 물에서 불소, 칼슘 및 마그네슘 함량에 관한 조사 연구)

  • 이인규;김종규
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.38-44
    • /
    • 2003
  • This study was performed to investigate the levels of fluoride (F), calcium (Ca), and magnesium (Mg) in water samples taken from five reservoirs or direct sources on a stream used for agricultural or domestic water in the Iksan and Wanjoo areas, Jeon-buk, Korea, and to find a possible link between Ca or Mg and fluoride in water sources in theses areas. The samples were collected by the recommendation methods of the World Health Organization and analyzed by the recommendations of the Japanese Standard Methods. Statistical analyses were performed by the analysis of variance and correlation analysis. The F levels in water samples wire 0.80~2.53 ppm. In four sampling sites the water fluoride levels exceeded 1 ppm. which if the recommended level for fluorosis/caries control. The Ca levels in water samples were 6.82~12.98 ppm, and the Mg levels were 0.30~1.97 ppm, which are lower compared with the natural levels of water sources previously reported by other investigators. This study showed a positive correlation between Ca and Mg (r= 0.8779. p<0.01) and a negative correlation between F and Ca (r=-0.6974, p<0.05) and also between F and Mg (r=-0.5581) in the water samples. However, the study did not find remarkable relationships in fluoride levels between sampling sites. These results support the fact that there were epidemics of dental fluorosis in this area. The lack of significant positive correlations in fluoride levels between sampling sites suggests that there may be some pathways for the transfer of the metal to the water through other environmental media besides the water course. Long-term epidemiological studies are needed on the relationship between high F together with low Ca and Mg levels in the water, and total human health in this community. There should alto be a long-term monitoring of the water quality in this area.

Hybrid neutralization and membrane process for fluoride removal from an industrial effluent

  • Meftah, Nouha;Ezzeddine, Abdessalem;Bedoui, Ahmed;Hannachi, Ahmed
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.303-312
    • /
    • 2020
  • This study aims to investigate at a laboratory scale fluorides removal from an industrial wastewater having excessive F- concentration through a hybrid process combining neutralization and membrane separation. For the membrane separation operation, both Reverse Osmosis (RO) and Nanofiltration (NF) were investigated and confronted. The optimized neutralization step with hydrated lime allowed reaching fluoride removal rates of 99.1± 0.4 %. To simulate continuous process, consecutive batch treatments with full recirculation of membrane process brines were conducted. Despite the relatively high super saturations with respect to CaF2, no membrane cloaking was observed. The RO polishing treatment allowed decreasing the permeate fluoride concentration to 0.9± 0.3 mg/L with a fluoride rejection rate of 93± 2% at the optimal transmembrane pressure of around 100 psi. When NF membrane was used to treat neutralization filtrate, the permeate fluoride concentration dropped to 1.1± 0.4 mg/L with a fluoride rejection rate of 88± 5% at the optimal pressure of around 80 psi. Thus, with respect to RO, NF allowed roughly 20% decrease of the driving pressure at the expense of only 5% drop of rejection rate. Both NF and RO permeates at optimal operating transmembrane pressures respect environmental regulations for reject streams discharge into the environment.

Validation of analysis of urinary fluoride by ion selective electrode method (이온선택전극법에 의한 소변 중 불소 이온 분석법 검증)

  • Lee, Mi-Young;Yoo, Kye-Mook
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.333-338
    • /
    • 2014
  • A simple and sensitive analytical method for fluoride in urine by ion selective electrode (ISE) method was presented. Traditional buffer for fluoride determination using ISE is acetate-based one. Researchers have pointed out some drawbacks of the buffer for fluoride ISE analysis, and some other buffers including citrate-ammonium buffer and MES buffer have been studied for accurate determination of fluoride in urine here. These buffers provided promising results in environmental field, and this author focused on overcoming the interference of co-existing aluminium. The results show that MES-CyDTA buffer gave the best recovery with accuracy of 95-97.5% and precision of 1.9-7.9% for reference sample of 1.8-7.8 mg/L fluoride in urine, with smaller amount of samples and shorter analysis time compared with the traditional method which used acetate buffer. The method was applied to field samples, and which showed urinary of $0.98{\pm}0.38mg/g$ creatinine for workers in electric cable manufacturing factory (n=15) and $0.59{\pm}0.30mg/g$ creatinine for non-exposed workers (n=12).

EFFECTS OF FLUORIDE CONCENTRATION AND SEED MATERIAL ON SEEDED CRYSTAL GROWTH (불소의 농도와 Seed Material이 Crystal Growth에 미치는 영향)

  • Oh, Seung-Yeon;Jung, Il-Young;Kum, Kee-Yeon;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.560-574
    • /
    • 1997
  • The present study was undertaken to investigate the crystal growth onto human enamel mineral and synthetic hydroxyapatite(HA) seeds in media resembling the enamel fluid composition. Effects of fluoride at high concentrations on the precipitation were also examined in a bench-top crystal growth model adopting a miniaturized reaction column. The Ca, P and F concentrations and pH values of the inlet and outlet solutions were determined. The recovered solid samples were weighed to assess the amount of minerals precipitated during the experimental period, and finally viewed under a scanning electron microscope. Remarkable findings were that 1) both biological and synthetic seeds with the same total surface areas yielded similar amounts of crystal growth, 2) the amount of crystal growth was accelerated in a manner depending on fluoride concentrations in the media, 3) SEM observations disclosed that without the addition of fluoride, precipitation of thin, plate-like OCP crystals became prominent, but by increasing the fluoride concentration(beyond 1ppm F), rod-like crystals having a pointed edge were most frequently observed, without any evidence for precipitation of the plate-like crystals. Furthermore, the dimension of rod-like crystals was increased in proportion to fluoride concentrations, 4) there was no difference in the morphological feature of precipitated mineral phase upon seeding between human enamel seed and synthetic HA seed. The overall results support the view that the seeded crystal growth model is of value to gain insight into the mechanism of enamel crystal growth under fluoride regimens.

  • PDF

Removal Characteristics of Fluoride Ions by PSf-Al(OH)3 Beads Immobilized Al(OH)3 with Polysulfone (Polysulfone으로 Al(OH)3를 고정화한 PSf-Al(OH)3 비드에 의한 불소 이온의 제거 특성)

  • Jeon, Jin-Woo;Lee, Min-Gyu
    • Clean Technology
    • /
    • v.20 no.1
    • /
    • pp.51-56
    • /
    • 2014
  • In this study, PSf-$Al(OH)_3$ beads were prepared by immobilizating aluminum hydroxide $Al(OH)_3$ with polysulfone (PSf). The removal experiments of the fluoride ions by PSf-$Al(OH)_3$ beads were conducted batchwise and the parameters such as pH, initial fluoride concentration, and coexisting ions were investigated. The maximum removal capacity obtained from Langmuir isotherm was 52.4 mg/g and the optimum pH region of fluoride ions was in the range of 4 to 10. The removal process of fluoride ions by PSf-$Al(OH)_3$ beads was found to be controlled by both external mass transfer at the earlier stage followed by internal diffusion at the later stage. The presence of coexisting anions such as $HCO_3{^-}$, $SO{_4}^{2-}$, $NO_3{^-}$, and $Cl^-$ had a negative effect on removal of fluoride ions by PSf-$Al(OH)_3$ beads.