• Title/Summary/Keyword: fluorescent image

Search Result 122, Processing Time 0.026 seconds

Multimodal Digital Photographic Imaging System for Total Diagnostic Analysis of Skin Lesions: DermaVision-Pro (다모드 디지털 사진 영상 시스템을 이용한 피부 손상의 진단적 분석에 대한 연구 : DermaVision-Pro)

  • Bae, Young-Woo;Kim, Eun-Ji;Jung, Byung-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.153-154
    • /
    • 2008
  • Digital photographic analysis is currently considered as a routine procedure in clinic because periodic follow-up examinations can provide meaningful information for diagnosis. However, it is impractical to separately evaluate all suspicious lesions with conventional digital photographic systems, which have inconsistent characteristics of the environmental conditions. To address the issue, it is necessary for total diagnostic evaluation in clinic to integrate conventional systems. Previously, a multimodal digital photographic imaging system, which provides a conventional color image, parallel and cross polarization color images and a fluorescent color image, was developed for objective evaluation of facial skin lesions. Based on our previous study, we introduce a commercial product, "DermaVision-PRO," for routine use in clinical application in dermatology. We characterize the system and describe the image analysis methods for objective evaluation of skin lesions. In order to demonstrate the validity of the system in dermatology, sample images were obtained from subjects with various skin disorders, and image analysis methods were applied for objective evaluation of those lesions.

  • PDF

Observer System with Image Processing Method for Automation Intervention Treatment (인터벤션시술의 자동화를 위한 영상처리방법으로 구현된 관측기 시스템 (실시간 혈관조영 영상 제공방법에 관한 연구))

  • Kim, Jee-Hong;Ryu, Ji-Hyoung;Chong, Kil-To
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.4
    • /
    • pp.422-427
    • /
    • 2014
  • This study provides a method to detect blood vessels shape using image processing techniques with the help of fluoroscopy equipments, providing high precision information about vessels' location and shape of inner path. It will assist for checking and monitoring the position of operating tools during vascular interventional treatment. The blood vessels shapes are gathered with X-ray images when a fluorescent medications are injected into patient's vessel and those images are processed for getting the boundaries of vessels. Then these data are merged with real-time CT-images. These image processing systems and procedures recognize the catheter, though continued computing algorithms are very useful for observer part on the automatic control system.

A Study of Real Time Verification System or Radiation Therapy (방사선치료 위치 실시간 검증시스템에 관한 연구)

  • Kim, Y.J.;Ji, Y.H.;Lee, D.H.;Lee, D.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.164-167
    • /
    • 1997
  • The treatment setup of patients during irradiation is an important aspect in relation to the success of radiotherapy. Imaging with the treatment beam is a widely used method or verification of the radiation field position relative to the target area, prior to or during irradiation. In this paper, Real time digital radiography system was implemented or verification of local error between simulation plan and radiation therapy machine. Portal image can be acquired by CCD camera, image board and pentium PC after therapy Radiation was converted into light by a metal/fluorescent Screen. The resulting image quality is comparable to film, so the imaging system represents a promising alternative to film as a method of verifying patient positioning in radiotherapy. Edge detection and field size measurement were also implemented and detected automatically for verification of treatment position. Field edge was added to the original image or checking the anatomical treatment verification by therapy technicians. By means of therapy efficiency improvement and decrease of Radiation side effects with these techniques, Exact Radiation treatments are expected.

  • PDF

The Development of Visual Inspection for Length Measurement of Injection Product Using Vision System (Vision System을 이용한 사출제품의 길이 측정용 시각검사 System 개발)

  • J.Y. Kim;B.S. Oh;S. You
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.126-134
    • /
    • 1997
  • In this study, We made visual inspection system using Vision Board. It is consist of an illuminator (a fluorescent lamp), image input device (CCD (Charge-Coupled Device) camera), image processing system(Vision Board(FARAMVB-02)), image output device (video monitor, printer), and a measuring instrument(TELMN1000). Length measurement by visual inspection system make use of 100mm guage block(instead of calculating distance between a camera and a object). It measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measure- ment of a injection. A measuring instrument used to ompare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument with visual inspecion system using length factor of 100mm gauge block. We find that maximum error of length is 0.55mm when it compar with the measuring value of two devices(FARAMVB-02, TELMN1000). Program of visual inspection system is made up Borland C++3.1.

  • PDF

Tubular Jacquard Knit Wear Design through the Application of Keith Haring's Works (키스 해링[Keith Haring]의 작품을 응용한 니트웨어 디자인 - 튜블러 자카드 조직을 활용하여 -)

  • Lee, Ha-Jung;Lee, Youn-Hee
    • Journal of the Korean Society of Costume
    • /
    • v.61 no.1
    • /
    • pp.69-83
    • /
    • 2011
  • This study applied cartoon-like simple and implicit symbol of Keith Haring works to tubular jacquard knit, designed woman casual knit wear with fun, explicit and activities using fluorescent yarns with explicit features. This study aimed to propose the directions for new market pioneering that meets the emotional requirements of modern people by raising the level of utilization and expression area of knit fashion, and to present the constructive directions for high value-added knit wear by designing highly effective knit wear. Methods of this study examined the lifetime and artistic background of Keith Haring and collected his works through searching of internet, scholastic publications or thesis. Formative types and colors of works collected were analyzed and classified according to characteristic standards of Haring and characteristic formativeness and color of works were extracted. The result of this study is as shown below: First, the feature of his works can be summarized into motif that has symbolic and implicit cartoon-like lines including narratives as well as enormous number of works. Such feature is very suitable for variation and recombination in realization of design and has unlimited potentials for development. Second, image colors can be extracted such as black and white, original color and fluorescent paints, which reflects the intention of artist who put focus on communication with the public. Such color feature is very suitable for design motif that has explicitness of reflecting the intention of artist through use of special fluorescent yarn. Third, I made it as reversible wear that has effects of increasing or decreasing the explicitness according to color area ratio using the feature of textures allowing use of both sides as well as form stability of tubular jacquard. Fourth, by adjusting the thickness of fabric with controlling of ply in fabric using poly yarn and wool union yarn, I could obtain good results of study in terms of technique that can express various materials with embossed dynamic effects of unevenness on flat surface.

An Experimental Investigation of Air Fuel Ratio Measurement using Laser Induced Acetone Fluorescence (아세톤 형광을 이용한 공연비 측정 기법 연구)

  • Park Seungjae;Huh Hwanil;Oh Seungmook
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.353-356
    • /
    • 2002
  • Planar laser induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Preliminary investigation was performed to measure quantitative air excess ratio distribution in an engine fueled with LPG. It is known that fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone was excited by KrF excimer laser (248nm) and its fluorescence image was acquired by ICCD camera with a cut-of filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile was suggested. Raw images were divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which was taken by a calibration process, were converted to air excess ratio distribution. This investigation showed instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

  • PDF

On the Dynamic Characteristics of Cell Contact by Analyzing TIRE Images (전반사 형광 이미지 분석을 통한 세포 부착점의 운동 특성에 관한 연구)

  • Lee, Yong-Ku;Jin, Song-Wan;Koo, Sang-Mo;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.380-387
    • /
    • 2007
  • We carried out an image analysis of living cells forming their contacts at the bottom of the cell culturing substrate. In order to visualize the contact area selectively, we adopted total-internal-reflection-fluorescence (TIRF) method, which can illuminate the specimen volume within only several hundred nano-meters above the substrate. From the fluorescent intensity of the TRF image, we could calculate the distance of the cell surface from the substrate. As a result, we visualized the origin of cell contacts, their movements, and the change of cell-contact type from the close-contact into focal-contact with information of its vertical displacement representing the temporal evolution process of the three-dimensional cell-surface-profile near the contact area during this metamorphosis.

Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray (엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성)

  • Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.256-263
    • /
    • 2017
  • By using the buildup characteristics of the radiophotoluminescence glass dosimeter(RPLGD), it is aimed to help the measurement of the accurate dose by measuring the radiation dose according to the time of the glass element. Five glass elements were arranged on the table and the source to image receptor distance(SID) was set to 100 cm for the build-up radiation dose measurement of the fluorescent glass dosimeter glass element(GD-352M). Radiation doses and saturation rates were measured over time according to irradiation time, with the tube voltage (30, 60, 90 kVp) and tube current (50, 100 mAs) Repeatability test was repeated ten times to measure the coefficient of variation. The radiation dose increased from 0.182 mGy to 12.902 mGy and the saturation rate increased from 58.3% with increasing exposure condition and time. The coefficient of variation of the glass elements of the fluorescent glass dosimeter was ranged from 0.2 to 0.77 according to the X - ray exposure conditions. X - ray exposure showed that the radiation dose and saturation rate were increased with buildup characteristics, and degeneration of glass elements was not observed. The reproducibility of the variation coefficient of the radiation generator was included within the error range and the reproducibility of the radiation dose was excellent.

Color Correction for Uniformity Illumination using Multispectral Relighting (멀티스펙트럴 재조명을 이용한 균일 조명 색상 보정)

  • Sim, Kyudong;Park, Jong-Il
    • Journal of Broadcast Engineering
    • /
    • v.22 no.2
    • /
    • pp.207-213
    • /
    • 2017
  • In order to accurately perform multispectral imaging using a multiplexed illumination, intensity of illumination in a scene must be uniform. For image acquisition that requires accurate color information, even if not multispectral imaging, the illumination information must be accurate, and a flat light source or illumination calibration is performed for accurate illumination characteristics. In this paper, we propose a method of color correction to uniformly illuminate an image with non-uniform illumination intensity. The proposed method uses multispectral imaging instead of illumination calibration for color correction. First of all, we perform multispectral imaging with two images obtained from non-uniformity illumination to acquire spectral reflectance. The obtained reflection spectrum is relit as the illumination characteristic of the image obtained from general planar light such as fluorescent light or sunlight. By comparing the image obtained by relighting with the uniformly illuminated image, the non-uniformity of the illumination is confirmed, and the color correction is performed as the image obtained from the uniform image. It is expected that the experimental results will confirm whether the non-uniformity of the illumination is uniformly corrected and reduce the restriction of illumination in obtaining the color information of the image.

Development of Image-based System for Multiple Fluorescence Imaging Study (다중형광영상 연구를 위한 영상기반 시스템 개발)

  • Yoon, WoongBae;Kim, Hong Rae;Lee, Hyun Min;Kim, Young Jae;Kim, Kwang Gi;Yoo, Heon;Lee, Seung Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.12
    • /
    • pp.1445-1452
    • /
    • 2015
  • In these days, fluorescent materials such as ICG or 5-ALA is used for the brain surgery. The patients who underwent brain tumor surgery has been increased during last 30 years and the survivorship rate increased 22∼33% in 5 years. Recently, the Fluorescence induction surgery is developed for more safety and improved the resection rate for the glioma in the neurosurgery field. In this study, we proposed fluorescence area detection method for ICG and 5-ALA fluorescence induced surgery using acquired images from image processing. Accuracy was 99.21% from ICG images, and 99.51% from 5-ALA images. Matthews correlation coefficient was 88.67% from ICG images, and 90.49% from 5-ALA images.