• 제목/요약/키워드: fluorescence detection

검색결과 602건 처리시간 0.03초

Fluorescence Characteristic Spectra of Domestic Fuel Products through Laser Induced Fluorescence Detection

  • Wu, Ting-Nien;Chang, Shui-Ping;Tsai, Wen-Hsien;Lin, Cian-Yi
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권5호
    • /
    • pp.18-25
    • /
    • 2014
  • Traditional investigation procedures of soil and groundwater contamination are followed by soil gas sampling, soil sampling, groundwater sampling, establishment of monitoring wells, and groundwater monitoring. It often takes several weeks to obtain the analysis reports, and sometimes, it needs supplemental sampling and analysis to delineate the polluted area. Laser induced fluorescence (LIF) system is designed for the detection of free-phase petroleum pollutants, and it is suitable for on-site real-time site investigation when coupling with a direct push testing tool. Petroleum products always contain polycyclic aromatic hydrocarbon (PAH) compounds possessing fluorescence characteristics that make them detectable through LIF detection. In this study, LIF spectroscopy of 5 major fuel products was conducted to establish the databank of LIF fluorescence characteristic spectra, including gasoline, diesel, jet fuel, marine fuel and low-sulfur fuel. Multivariate statistical tools were also applied to distinguish LIF fluorescence characteristic spectra among the mixtures of selected fuel products. This study successfully demonstrated the feasibility of identifying fuel species based on LIF characteristic fluorescence spectra, also LIF seemed to be uncovered its powerful ability of tracing underground petroleum leakages.

Hyperspectral Fluorescence Imaging for Mouse Skin Tumor Detection

  • Kong, Seong G.;Martin, Matthew E.;Vo-Dinh, Tuan
    • ETRI Journal
    • /
    • 제28권6호
    • /
    • pp.770-776
    • /
    • 2006
  • This paper presents a hyperspectral imaging technique based on laser-induced fluorescence for non-invasive detection of tumorous tissue on mouse skin. Hyperspectral imaging sensors collect image data in a number of narrow, adjacent spectral bands. Such high-resolution measurement of spectral information reveals contiguous emission spectra at each image pixel useful for the characterization of constituent materials. The hyperspectral image data used in this study are fluorescence images of mouse skin consisting of 21 spectral bands in the visible spectrum of the wavelengths ranging from 440 nm to 640 nm. Fluorescence signal is measured with the use of laser excitation at 337 nm. An acousto-optic tunable filter (AOTF) is used to capture images at 10 nm intervals. All spectral band images are spatially registered with the reference band image at 490 nm to obtain exact pixel correspondences by compensating the spatial offsets caused by the refraction differences in AOTF at different wavelengths during the image capture procedure. The unique fluorescence spectral signatures demonstrate a good separation to differentiate malignant tumors from normal tissues for rapid detection of skin cancers without biopsy.

  • PDF

프리즘을 이용한 소형 단백질칩 분석 형광측정 시스템 개발 (Miniature Fluorescence Detection System for Protein Chips by Prism)

  • 최재호;김호성;이국녕;김은미;김용권;김병기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2040-2042
    • /
    • 2004
  • This paper presents a miniature optical system for the fluorescence detection of the patterned protein chip. The patterned protein chip was fabricated using MEMS process. The fluorescence from the patterned protein chip was measured while varying the concentration of the BSA. The fluorescence light is separated spatially from the excitation beam using mini-size prism to increase SNR (Signal-to-Noise Ratio). The combination of prism and mirrors can convert the excitation light from the laser diode to uniform illumination on the specimen. We believe that the proposed system for fluorescence detection can be applied to rea1ization of point-of-care.

  • PDF

In Situ Fluorescence Optical Detection Using a Digital Micromirror Device (DMD) for 3D Cell-based Assays

  • Choi, Jong-Ryul;Kim, Kyujung;Kim, Donghyun
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.42-46
    • /
    • 2012
  • We have developed a fluorescence optical detection system using a digital micromirror device (DMD) for monitoring 3D cell culture matrices in situ. Full 3D imaging with fast scanning speed was implemented by the combined action of a DMD and a motorized stage. Imaging results with fluorescent microbeads measure the minimum axial resolution of the system as $6.3{\mu}m$, while full 1-mm scanning through 3D alginate-based matrix was demonstrated. For cell imaging, improved images were obtained by removing background fluorescence although the scanning distance was reduced because of low intracellular fluorescence efficiency. The system is expected to be useful to study various dynamics and behaviors of 3-dimensionally cultured cells in microfluidic systems.

레이저 형광법을 이용한 인접면 우식증 탐지효과 (DETECTION OF PROXIMAL CARIES USING LASER FLUORESCENCE)

  • 모경희;윤정훈;김수관;이상호
    • 대한소아치과학회지
    • /
    • 제31권2호
    • /
    • pp.323-330
    • /
    • 2004
  • 본 연구는 레이저 형광을 치아의 인접면에 적용하여 임상에서 초기 인접면 우식증의 감별에 레이저의 이용가능성을 평가하는데 그 목적이 있다. 염료와 레이저 형광법의 인접면 우식증 탐지효과를 평가하기 위해 조선대학교 소아치과에 내원한 아동 중 유구치의 탈락이 없으며 인접면의 수복치료를 받지 않은 $3{\sim}9$세 사이의 어린이 30명을 대상으로 하였으며, 시진, 교익 방사선사진, 레이저 형광법, 염료와 레이저 형광법을 이용해 관찰한 결과를 비교하여 다음과 같은 결과를 얻었다. 1. 인접면 우식증의 교익 방사선 사진검사와 시진, 레이저 형광법, 염료와 레이저 형광법 사이에서 모두 높은 상관 관계(r=0.725-0.911)를 보였다(p<0.05). 2. 인접면 우식증의 교익 방사선사진 검사와 각 검사법간의 일치도(kappa치)는 각각 시진이 0.451 레이저 형광법이 0.683, 염료와 레이저 형광법이 0.772로 가장 일치도가 높았다. 이상의 결과를 종합해 보면 교익 방사선사진 검사법과 염료와 레이저 형광법 검사 수치의 상관관계가 진단학적 일치도가 높아 레이저 형광법이 향후 교익방사선 사진 검사법을 대치 할 수 있는 인접면 우식증 검사법으로 사료된다.

  • PDF

405 nm 광원을 이용한 생물입자탐지기의 에어로졸 분석성능 (The performance of Bio-aerosol Detection System (BDS) with 405 nm laser diode)

  • 정영수;정유진;이종민;최기봉
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.25-31
    • /
    • 2017
  • This paper offer the characteristics for the detection and classification of biological and non-biological aerosol particles in the air by using laser-induced-fluorescence (LIF) based Bio-aerosol Detection System (BDS). The BDS is mainly consist of an optical chamber, in-outlet nozzle system, 405 nm diode laser, an avalanche photo detector (APD) for scattering signal and photomultiplier tubes (PMT) for fluorescence signals in two different wavelength range ; F1, 510-600 nm and F2, 435-470 nm. The detection characteristics, especially ratio of fluorescence signal intensity were examined using well-known components : polystylene latex (PSL), fluorescence PSL, $2{\mu}m$ of SiO2 micro sphere, dried yeast, NADH, ovalbumin, fungicide powder and standard dust. The results indicated that the 405 nm diode laser-based LIF instrument can be a useful bio-aerosol detection system for unexpected biological threaten alter in real-time to apply for dual-use technology in military and civilian fields.

레이저 우식진단기기 'DIAGNODent$^{(R)}$'의 활용 (Use of laser fluorescence device 'DIAGNODent$^{(R)}$' for detecting caries)

  • 이병진
    • 대한치과의사협회지
    • /
    • 제49권8호
    • /
    • pp.461-471
    • /
    • 2011
  • The detection of carious lesions is a key point to apply appropriate preventive measures or operative treatment of dental caries. A laser fluorescence device DIAGNOdent$^{(R)}$ (KaVo, Biberach, Germany) has also been shown to be of additional clinical value in the detection of initial caries. This report focus on the DIAGNOdent$^{(R)}$ for caries detection. DIAGNOdent$^{(R)}$ irradiate visible red light at a wavelength of 655 nm to elicit near-infrared fluorescence from caries lesion. This device is known as a reproducible method for caries detection, with good sensitivity and specificity especially for caries detection on occlusal and accessible smooth surfaces. DIAGNOdent$^{(R)}$ tended to be more sensitive method of detecting occlusal dentinal caries, however, showed more false-positive diagnoses than the visual inspection. So Clinician should not use the device as a clinician's primary diagnostic method and it is recommended that the device should be used in the decision-making process in relation to the diagnosis of caries as a second opinion in cases of doubt after visual inspection. The trend of modern dentistry would be a preventive approach rather than invasive treatment of the disease. This is possible only with early detection and respective preventive measures, DIAGNOdent$^{(R)}$ can help the changes.

Fluorescence Immunoassy of HDL and LDL Using Protein A LB Film

  • Choi, Jeong-Woo;Park, Jun-Hyo;Lee, Woo-Chang;Oh, Byung-Keun;Min, Jun-Hong;Lee, Won-Hong
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권6호
    • /
    • pp.979-985
    • /
    • 2001
  • A fluorometric detection technique for HDL (High Density Lipoprotein) and LDL (Low Density Lipoprotein) was developed for application in a fiber-optic immunosensor using a protein A Langmuir-Blodgget (LB) film. For the fluorescence immunoassay, antibodies specific to HDL or LDL were imobilied on the protein A LB film, and a fluorescence amplification method was developed to overcome their weak fluorescence. The deposition of protein A using the LB technique was monitored using a surface pressure-are $({\pi}-A)$ curve, and the antibody immobilization of the protein A LB film was experimentally verified. The immobilized antibody was used to separate only HDL and LDL from a sample, then the fluorescence of he separated HDL or LDL was amplified. The amount of LDL or HDL was measured using the developed fiber optic fluorescence detection system. The optical properties resulting from the reaction of HDL or LDL with o-phtaldialdehyde, detection range, response time, and stability of the immunoassay were all investigated. The respective detection ranges for HDL and LDL were sufficient to diagnose the risk of coronary heart disease. The amplification step increased the sensitivity, while selective separation using the immobilized antibody led to linearity in the sensor signal. The regeneration of the antibody-immobilized substrate could produce a stable and reproducible immunosensor.

  • PDF

LOC 형광검출 소자를 위한 광 다이오드의 제작 및 특성 평가 (Development of Photo-diode for LOC fluorescence detector)

  • 김주환;신경식;김용국;김상식;주병권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.100-103
    • /
    • 2003
  • Signal detection technologies such as fluorescence, charge and electrochemical detection used in the monolithic capillary electrophoresis system to convert the biochemical reaction into the electrical signal. The fluorescence detection using photodiodes that measure fluorescence emitted from eluting molecules is widely used for the monolithic capillary electrophoresis system. In this paper, in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. The p-i-n diode has higher sensitivity than photodiode. Considering these results, we fabricated p-i-n diodes on the high resistive$(4k{\Omega}{\cdot}cm)$ wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of p-i-n diode can be decreased by the application of finger pattern has parallel resistance structure from $571{\Omega}$ to $393{\Omega}$.

  • PDF

형광 발현 암세포 탐지를 위한 맞춤형 검출시스템 개발 (Design of a customizable fluorescence detection system for fluorescently labeled tumor cells)

  • 조경래;서정혁;최세운
    • 한국정보통신학회논문지
    • /
    • 제23권3호
    • /
    • pp.261-266
    • /
    • 2019
  • 유동 세포 분석법은 세포나 입자에 대하여 정밀하고 다양한 광학적 특성을 제공해주는 전기적 탐지 기술이다. 형광 처리된 세포나 미립자에 특정한 파장의 빛을 가함으로써 발생 되는 광 산란과 형광 방출을 통해 세포의 크기와 입상도를 포함한 다차원적인 정보를 제공해주는 유동 세포 분석법은 생체 의학 분야 또는 생물 물리학 분야에서 중요한 역할을 수행한다. 그러나 유동 세포 분석법은 고가이며 장비 설치에 있어 적절한 공간이 필요하고 형광 염료 선택에 제한적이라는 단점을 가지고 있다. 따라서 본 논문에서는, 상용화된 유동 세포 분석에 사용되는 고가의 레이저와 운영시스템 대신 발광 다이오드, 마이크로 컨트롤러와 광 검출기를 사용한 저가의 형광세포 측정 시스템을 개발하여 사용자가 원하는 형광 염료에 대한 자유도를 높였다. 또한, 3D 프린터를 사용하여 모듈별 소형화 및 경량화를 통한 사용자 맞춤형 제작이 가능하도록 하였다. 그 결과, 형광처리 한 세포의 양에 변화를 주어 발광도를 측정하였을 때, 높은 선형성이 보임을 확인할 수 있었다.