• 제목/요약/키워드: fluorescence detection

검색결과 602건 처리시간 0.031초

실시간 미세플라스틱 카운팅을 위한 레이저 유도 형광 특성 분석 (Laser-Induced Fluorescence Characterization for Real-Time Microplastic Counting)

  • 고승현;오금윤
    • 한국전기전자재료학회논문지
    • /
    • 제35권2호
    • /
    • pp.149-154
    • /
    • 2022
  • In this paper, laser-induced fluorescence properties of four plastics were characterized through spectrometer analysis for real-time microplastic counting. Recently, environmental problems related to microplastics have emerged. In order to detect microplastics, analysis methods such as FT-IR and Raman are used. However, they have the disadvantages of being time-consuming and requiring a pretreatment process. In most plastic products on the market, 10% to 30% of plasticizers and reinforcing agents are added. Therefore, most microplastics present in seawater and freshwater emit fluorescence signals by 270 nm UV light source regardless of their type due to their molecular structure due to additives. Real-time microplastics counting is possible more easily by using the proposed laser-induced fluorescence detection method because of the fluorescence expression characteristic of 340 nm that appears due to the plasticizer of plastics.

레이저를 이용한 용액중의 미량 우라늄 분석 (Trace Analysis of Uranium in Aqueous Samples by Laser-induced Fluorescence Spectroscopy)

  • Jung, Kwang-Woo;Kim, Jeong-Moog;Kim, Cheol-Jung;Lee, Jong-Min
    • Nuclear Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.242-248
    • /
    • 1987
  • 레이저를 이용한 형광분석 방법과 형광의 세기를 증대시켜주는 'Fluran' 용액을 가함으로써 용액속에 존재하는 미량의 우라늄을 정착하고 신속하게 분석할 수 있는 새로운 장치를 개발하였다. 표준용액의 첨가 방법을 이용하여 시료의 조성 변화에 따른 형광의 방해효과를 보정할 수 있었고 5%이내의 정밀도를 갖는 0.1ppb의 측정 하한치를 얻을 수 있었다. 또한 여러 종류의 시료에 대하여 레이저를 이용한 형광분석 방법의 결과와 다른 측정 방법에 의한 결과를 상호 비교, 분석하였다.

  • PDF

CdTe Quantum Dots as Fluorescent Probes for Josamycin Determination

  • Peng, Jinyun;Nong, Keliang;Mu, Guangshan;Huang, Fengying
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2727-2731
    • /
    • 2011
  • A new method for the determination of josamycin has been developed based on quenching of the fluorescence of 3-mercaptopropionic acid-capped CdTe quantum dots (MPA-CdTe QDs) by josamycin in ethanol. Reaction time, interfering substances on the fluorescence quenching, and mechanism of the interaction of CdTe QDs with josamycin were investigated. Under optimum conditions, the relative fluorescence intensity was linearly proportional to the concentration of josamycin between 12.0 and 120.0 ${\mu}g\;mL^{-1}$ with a correlation coefficient of 0.9956 and a detection limit of 2.5 ${\mu}g\;mL^{-1}$. The proposed method was successfully applied to commercial tablets, and the results were satisfactory, i.e. consistent with those of high-performance liquid chromatography (HPLC).

FISH(fluorescence in situ hybridization)를 이용하여 분석한 크롬에 의해 유발된 염색체 이상 (Detection of Chromosomal Rearrangements by Chromium in Human Lymphocyte Using Fluorescence in situ Hybridization (FISH) with Triple Combination of Composite whole Chromosome Specific Probe)

  • 정해원;김수영;맹승희;이용묵;유일재
    • 한국환경성돌연변이발암원학회지
    • /
    • 제19권1호
    • /
    • pp.14-19
    • /
    • 1999
  • Chromosome rearrangements induced in human lymphocyte after in vitro exposure to chromium were analysed by the use of fluorescence in situ hybridization(FISH) with triple combination of composite whole chromosome-specific probe for chromosome 1, 2 and 4. Chromosome aberrations was scored by the Protocol for Aberration Identification and Nomenclature Terminology (PAINT). Stable translocation was the most frequent type of aberrations and dicentrics and insertions were also observed. Chromium treatment enhanced the frequencies of stable translocations and color junctions in a dose-dependent manners, but no distinct increase of dicentrics and insertions was seen. The ratio of the yields of translocation to the yields of dicentric varied between 13 to 27. The presents results demonstrate fluorescent in situ hybridization (FISH) is useful for detecting chromosomal rearrangements induced by chromium.

워터쉐드를 이용한 피부암 영역 추출 (A Skin Cancer Region Extraction Using Watershed)

  • 한재복;김진영;유홍연;홍성훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.877-878
    • /
    • 2006
  • In this paper, we propose a skin lesion detection to develop the system of fluorescence image analysis to identify the fluorescence of topical methyl aminolevulinate(MAL) idduced PpIX in patients with BCC accurately. By fluorescence image analysis we define the border between tumo and tumor-free areas on fluorescence image after topical application of MAL ointment. We excised both the tumor and peri-tumoral areas widely from the 10 patients with BCC, and divided tissue samples into 3 area, such as tumor area, suspected tumor area, tumor-free area, respectively. Our proposed method migt play a role as an adjunctive tool to define the border between tumor and tumor-free areas for Mohs' micrographic surgery.

  • PDF

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

Comparison of Clinical Characteristics of Fluorescence in Quantitative Light-Induced Fluorescence Images according to the Maturation Level of Dental Plaque

  • Jung, Eun-Ha;Oh, Hye-Young
    • 치위생과학회지
    • /
    • 제21권4호
    • /
    • pp.219-226
    • /
    • 2021
  • Background: Proper detection and management of dental plaque are essential for individual oral health. We aimed to evaluate the maturation level of dental plaque using a two-tone disclosing agent and to compare it with the fluorescence of dental plaque on the quantitative light-induced fluorescence (QLF) image to obtain primary data for the development of a new dental plaque scoring system. Methods: Twenty-eight subjects who consented to participate after understanding the purpose of the study were screened. The images of the anterior teeth were obtained using the QLF device. Subsequently, dental plaque was stained with a two-tone disclosing solution and a photograph was obtained with a digital single-lens reflex (DSLR) camera. The staining scores were assigned as follows: 0 for no staining, 1 for pink staining, and 2 for blue staining. The marked points on the DSLR images were selected for RGB color analysis. The relationship between dental plaque maturation and the red/green (R/G) ratio was evaluated using Spearman's rank correlation. Additionally, different red fluorescence values according to dental plaque accumulation were assessed using one-way analysis of variance followed by Scheffe's post-hoc test to identify statistically significant differences between the groups. Results: A comparison of the intensity of red fluorescence according to the maturation of the two-tone stained dental plaque confirmed that R/G ratio was higher in the QLF images with dental plaque maturation (p<0.001). Correlation analysis between the stained dental plaque and the red fluorescence intensity in the QLF image confirmed an excellent positive correlation (p<0.001). Conclusion: A new plaque scoring system can be developed based on the results of the present study. In addition, these study results may also help in dental plaque management in the clinical setting.

Fluorescence-Quenched Sensor for Trinitophenol in Aqueous Solution Based on Sulfur Doped Graphitic Carbon Nitride

  • Min, Kyeong Su;Manivannan, Ramalingam;Satheshkumar, Angu;Son, Young-A
    • 한국염색가공학회지
    • /
    • 제30권2호
    • /
    • pp.63-69
    • /
    • 2018
  • In this study, we report on successful attempt towards the synthesis of sulfur self-doped $g-C_3N_4$ by directly heating thiourea in air. The synthesized materials were characterized using UV-vis spectral technique, FT-IR, XRD and TEM analysis. Further, the obtained material shows an excellent detection of carcinogenic TNP(Tri nitro phenol) in the presence of 10-fold excess of various other common interferences. The strong inner filter effect and molecular interactions(electrostatic, ${\pi}-{\pi}$, and hydrogen bonding interactions) between TNP and the $S-g-C_3N_4$ Nano sheets led to the fluorescence quenching of the $S-g-C_3N_4$ Nano sheets with an excellent selectivity and sensitivity towards TNP compared to that of other nitro aromatics under optimal conditions and the detection limit calculated was found to be 6.324 nM for TNP. The synthesized nanocomposite provides a promising platform for the development of sensors with improved reproducibility and stability for ultra-sensitive and selective sensing of TNP.

Multiresidue Determination of Quinolones in Porcine, Chicken, and Bovine Muscle Using Liquid Chromatography with Fluorescence Detection

  • Lee, Sang-Hee;Shim, You-Sin;Kim, Hyun-Ju;Shin, Dong-Bin
    • Food Science and Biotechnology
    • /
    • 제18권4호
    • /
    • pp.978-984
    • /
    • 2009
  • An analytical method for the simultaneous determination of 9 quinolones (QNs) in porcine, chicken, and bovine muscles was developed and validated using liquid chromatography-fluorescence detector (LC-FLD). The samples were extracted using a liquid-liquid extraction (LLE) process. Chromatographic separation was achieved on a reverse phase $C_8$ column with a gradient elution using a mobile phase of 200 mM ammonium acetate buffer (pH 4.5) and acetonitrile (ACN). The proposed method was validated according to the Food and Drug Administration (FDA) guideline for bioanalytical assay procedures. Recoveries of QNs were 83.1-111.9% with relative standard deviations (RSDs) below 15%. Linearity within a range of 30-500 ${\mu}g/kg$ was obtained with the correlation coefficient ($R^2$) of 0.9967-0.9999. The limits of detection (LOD) were 1-16 ${\mu}g/kg$. These values were lower than the maximum residues limits (MRLs) established by the European Union (EU). The present method was successfully applied to determine QNs in edible muscles.

A Quinoline carboxamide based Fluorescent Probe's Efficient Recognition of Aluminium Ion and its Application for Real Time Monitoring

  • Manivannan, Ramalingam;Ryu, Jiwon;Son, Young-A
    • 한국염색가공학회지
    • /
    • 제32권4호
    • /
    • pp.185-192
    • /
    • 2020
  • A novel binding site for metal ion made by designing molecule with tetrazolo quinoline with hydrazine carboxamide (TQC) and the designed molecule successfully synthesized. The probe works by selectively detecting Al3+ ion via both fluorimetric and colorimetric approach. The probe's effectiveness towards aluminium ion detection is highly sensitive and selective with no substantial interference with other competing ions. The added Al3+ ion to TQC fetched a rapid change of visual color to yellow from colorless, also the response of fluorescence turn-on. The fluorescence turn-on and color change visibly by the probe TQC with Al3+ ion credited to the ICT phenomenon (intramolecular charge-transfer transition). The likely interaction of the probe with aluminium ion has also been there predicted from ESI-MS spectral analysis results. The usefulness of the probe confirmed by practical utility by making a test kit to monitor Al3+ ion in water which showed a naked eye detection by notable color change.