• 제목/요약/키워드: fluid form

검색결과 635건 처리시간 0.032초

전자기력에 의한 자성유체의 2차원 자유표면 형상 제어에 관한 연구 (Study on the two-dimensional Formation Control of Free Surface of Magnetic Fluid by Electromagnetic Force)

  • 안창호;지병걸;이은준;박명관
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.979-982
    • /
    • 2003
  • In this study, because of change in electromagnetic force, deformation of the free surface motion of a magnetic fluid is changed. Deformation of the free surface motion of a magnetic fluid for the change in electromagnetic force is discussed and carried out theoretically and experimentally on the basis of Rosensweig Ferrohydrodynamic Bernoulli Equation. Objective of this study explicates free surface motion by electromagnetic force and planes to designed controller. To control free surface of magnetic fluid, it embody designed two-dimensional free surface form of magnetic fluid. By using this characteristics, they applied to oscillator for surface control, flow control, boundary layer control. Strength of magnetic field and height of free surface of magnetic fluid measure as a hall-effect sensor. As performing height control of magnetic fluid, the result will be presented possibility of free surface deformation control.

  • PDF

재질과 자기장 세기가 자기유변유체의 마찰 특성에 미치는 영향 (A Study on the Effect of the Material and Applied Magnetic Field Strength on the Friction Characteristics of Magnetorheological Fluids)

  • 장붕;이광희;이철희
    • Tribology and Lubricants
    • /
    • 제29권1호
    • /
    • pp.39-45
    • /
    • 2013
  • Magnetorheological (MR) fluid belongs to the group of smart materials. In MR fluid, iron particles in base oil form chains in the direction of the applied magnetic field, thus resulting in a variation in the stiffness and damping characteristics of the fluid. Research is being carried out on controlling the stiffness and damping characteristics as well as the tribological characteristics of the MR fluid. In this study, the friction characteristics of MR fluid have been evaluated using three types of materials and magnetic fields of different strengths. The coefficients of friction of the three types of MR fluid are measured, and the relationship between the coefficient of friction and the strength of the applied magnetic field is obtained.

Sr 페라이트의 총형연삭특성 (Form grinding characteristics of Sr ferrite)

  • 김성청;이재우
    • 한국정밀공학회지
    • /
    • 제14권3호
    • /
    • pp.21-27
    • /
    • 1997
  • This paper aims to clarify the effects of grinding conditions in form grinding of Sr-ferrite with the electro-plated diamond wheel. The main conclusions obtained were as follows. (1) The flexural strength and surface roughness of ferrite became the best at the peripheral wheel speed of 1700 m/min. (2) In the case of the depth of cut larger than 0.4mm, crack layers is induced in the ground surface, and the fracture type of chips exhibits slight ductile mode in the depth of cut smaller than 0.2mm. (3) Whe the depth of cut exceeds 0.6mm, the wheel life becomes extremely severe due to the large chipping and brack- age in the diamond grains. However, at the depth of cut .leq. 0.05mm, the diamond grain shows abrasive wear. (4) The decrease of flexural strength and the increase of surface roughness is in proportion to the increase of the feed rate. (5) Most effective nozzle setting angles with various delivery conditions of the grinding fluid, such as nozzle position .PHI. , flow rate Q, etc., were made clear.

  • PDF

Analytics of PIV Measurement and Its Application for Higher Performances

  • NISHIO Shigeru;SUGII Yasuhiko
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2001년도 Proceedings of 2001 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.62-74
    • /
    • 2001
  • Present paper describes the principles of PIV measurement approaching from the analytical view, which enables to explain the general form of principles covering all the PIV measurement, and that gives theoretical basis for its higher measurement performances. The explanation of the measurement principles started from the definition of governing equation in differential form as same as the gradient method, and the integral along the particle path line was executed to show the principle of the correlation method with same basis. The integral processes clearly shows the analytical reason why the correlation peak gives the terminal point of path line, and how the effects of deformation and rotation of fluid appears in the correlation map. These results have no differences from our experiences and understandings of the conventional PIV measurement definition in final form. However, the analytical approach enable to understand those facts a priori, and it makes easy to achieve the innovative higher performances of measurement. Analytical explanation clearly shows the behavior of the residual errors caused by the fluid motion, and it enables to analyze the measurement uncertainty theoretically.

  • PDF

Audiogram in Response to Stimulation Delivered to Fluid Applied to the External Meatus

  • Geal-Dor, Miriam;Chordekar, Shai;Adelman, Cahtia;Kaufmann-Yehezkely, Michal;Sohmer, Haim
    • Journal of Audiology & Otology
    • /
    • 제24권2호
    • /
    • pp.79-84
    • /
    • 2020
  • Background and Objectives: Hearing can be elicited in response to vibratory stimuli delivered to fluid in the external auditory meatus. To obtain a complete audiogram in subjects with normal hearing in response to pure tone vibratory stimuli delivered to fluid applied to the external meatus. Subjects and Methods: Pure tone vibratory stimuli in the audiometric range from 0.25 to 6.0 kHz were delivered to fluid applied to the external meatus of eight participants with normal hearing (15 dB or better) using a rod attached to a standard clinical bone vibrator. The fluid thresholds obtained were compared to the air conduction (AC), bone conduction (BC; mastoid), and soft tissue conduction (STC; neck) thresholds in the same subjects. Results: Fluid stimulation thresholds were obtained at every frequency in each subject. The fluid and STC (neck) audiograms sloped down at higher frequencies, while the AC and BC audiograms were flat. It is likely that the fluid stimulation audiograms did not involve AC mechanisms or even, possibly, osseous BC mechanisms. Conclusions: The thresholds elicited in response to the fluid in the meatus likely reflect a form of STC and may result from excitation of the inner ear by the vibrations induced in the fluid. The sloping fluid audiograms may reflect transmission pathways that are less effective at higher frequencies.

Audiogram in Response to Stimulation Delivered to Fluid Applied to the External Meatus

  • Geal-Dor, Miriam;Chordekar, Shai;Adelman, Cahtia;Kaufmann-Yehezkely, Michal;Sohmer, Haim
    • 대한청각학회지
    • /
    • 제24권2호
    • /
    • pp.79-84
    • /
    • 2020
  • Background and Objectives: Hearing can be elicited in response to vibratory stimuli delivered to fluid in the external auditory meatus. To obtain a complete audiogram in subjects with normal hearing in response to pure tone vibratory stimuli delivered to fluid applied to the external meatus. Subjects and Methods: Pure tone vibratory stimuli in the audiometric range from 0.25 to 6.0 kHz were delivered to fluid applied to the external meatus of eight participants with normal hearing (15 dB or better) using a rod attached to a standard clinical bone vibrator. The fluid thresholds obtained were compared to the air conduction (AC), bone conduction (BC; mastoid), and soft tissue conduction (STC; neck) thresholds in the same subjects. Results: Fluid stimulation thresholds were obtained at every frequency in each subject. The fluid and STC (neck) audiograms sloped down at higher frequencies, while the AC and BC audiograms were flat. It is likely that the fluid stimulation audiograms did not involve AC mechanisms or even, possibly, osseous BC mechanisms. Conclusions: The thresholds elicited in response to the fluid in the meatus likely reflect a form of STC and may result from excitation of the inner ear by the vibrations induced in the fluid. The sloping fluid audiograms may reflect transmission pathways that are less effective at higher frequencies.

HYDROMAGNETIC FLUCTUATING FLOW OF A COUPLE STRESS FLUID THROUGH A POROUS MEDIUM

  • Zakaria, M.
    • Journal of applied mathematics & informatics
    • /
    • 제10권1_2호
    • /
    • pp.175-191
    • /
    • 2002
  • The equations of a polar fluid of hydromagnetic fluctuating through a porous medium axe cast into matrix form using the state space and Laplace transform techniques the resulting formulation is applied to a variety of problems. The solution to a problem of an electrically conducting polar fluid in the presence of a transverse magnetic field and to a problem for the flow between two parallel fixed plates is obtained. The inversion of the Laplace transforms is carried out using a numerical approach. Numerical results for the velocity, angular velocity distribution and the induced magnetic field are given and illustrated graphically for each problems.

NUMERICAL SOLUTION OF EQUILIBRIUM EQUATIONS

  • Jang, Ho-Jong
    • 대한수학회논문집
    • /
    • 제15권1호
    • /
    • pp.133-142
    • /
    • 2000
  • We consider some numerical solution methods for equilibrium equations Af + E$^{T}$ λ = r, Ef = s. Algebraic problems of this form evolve from many applications such as structural optimization, fluid flow, and circuits. An important approach, called the force method, to the solution to such problems involves dimension reduction nullspace computation for E. The purpose of this paper is to investigate the substructuring method for the solution step of the force method in the context of the incompressible fluid flow. We also suggests some iterative methods based upon substructuring scheme..

  • PDF

반능동형 오리피스 유체댐퍼의 성능 실험 (Experimental Study on the Performance of a Semi-Active Orificed Fluid Damper)

  • 문석준;김병현;정종안
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.387-394
    • /
    • 2003
  • A compromise between passive and active control systems has been developed recently in the form of semi-active control systems. Semi-active control systems maintain the reliability of passive control systems while taking advantage of the adjustability of an active control system. This paper presents the results of an experimental study to evaluate the performance of a semi-active orificed fluid damper. The semi-active orificed fluid damper considered is a two-stage damper with normally open solenoid valve. Through a series of experimental tests, characteristics and performance of the damper is investigated.

  • PDF

Controlled Release and Stabilization of Cefaclor from Alginate-based Matrices for Oral Delivery Design

  • Bak, So-Im;Lee, Jue-Yeon;Song, Hye-Won;Hwang, Jeong-Hyo;Lee, Seung-Jin
    • Journal of Pharmaceutical Investigation
    • /
    • 제32권4호
    • /
    • pp.327-330
    • /
    • 2002
  • Alginate based polymeric matrices were designed for controlled release and stabilization of cefaclor in gastrointestinal fluid. Cefaclor is known to be acid stable and subjected to be degraded at neutral and alkaline pHs. In order to achieve an effective release profile of cefaclor in gastrointestinal tract, a particular strategy in dosage form design should be required from the view point of maintaining its activity. The amphiphilic nature of cefaclor allowed its controlled release using ionic polymers based on ionic interaction between the drug and polymers. The thrust of this study was to develop a technique that delivers cefaclor keeping effective release rate in the intestinal tract. Considering the fast degradation of cefaclor in the intestinal fluid, the matrices were designed to release surplus amount of cefaclor. The alginate based matrices demonstrated increase in release rate in the simulated intestinal fluid, which was favorable to compensate the degraded portion of cefaclor. In addition, stabilization of cefaclor in the intestinal fluid was obtained by employing citric acid that provides an local acidic environment. The matrices might be valuably used for the development of an oral cefaclor dosage form.