• 제목/요약/키워드: flow tubes

검색결과 643건 처리시간 0.032초

수평관군 흡수기의 열 및 물질 전달특성에 관한 실험적 연구 (Experimental Study on Heat and Mass Transfer Characteristics in bundles of horizontal absorption tubes)

  • 설원실;정용욱;문춘근;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.113-120
    • /
    • 2000
  • On the absorber of absorption chiller/heater, LiBr solution at high concentration is sprinkled on a bundle of horizontal tube cooled by cooling water. In this case, the conditions of LiBr solution and cooling water have an influence on heat/mass transfer coefficient in this system. Therefor it is important to find optimal operation conditions of absorption chiller/heater to save energy. Heat and mass transfer coefficient increased with the increase of solution flow rate, and also heat and mass transfer rate increased but overall heat and mass transfer coefficient decreased by increasing the solution concentration within the experimental range. The superheating of the solution resulted in superior heat transfer character to a state of equilibrium from the point of heat flux and overall heat transfer coefficient.

  • PDF

동심관형 공명기의 천공 분포 및 연장관이 전달 손실에 미치는 특성 해석 (Effect of Non-uniform Perforation and Extended Inlet/outlet Length in the Concentric Resonator on the Transmission Loss)

  • 이성현;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.114-117
    • /
    • 2005
  • In the reactive concentric resonator, perforated inner tubes are widely used for various purposes related to noise reduction, flow guiding, and structural aspects. Perforation distribution patterns influence both the acoustic performance and mechanical performance. In this study, the influence of distribution patterns on acoustic performance are explained by adopting the concept of extended inlet/outlet length. Predicted transmission with varying extended inlet/outlet length is compared with prediction by varying distribution patterns. The transmission loss difference due to perforation distribution patterns can be explained by changing the extended inlet/outlet length of the uniformly perforated resonator.

  • PDF

디젤 매연여과기 (DPF) 내에서의 음향전파 (Sound Propagation through the Diesel Particulate Filter (DPF))

  • 최원용;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.152-155
    • /
    • 2005
  • Diesel particulate filter (DPF) is comprised of a number of capillary tubes enclosed by porous ceramic wails, shaped like a plugged duct. Hot gas flows through the DPF along with the exhaust noise from Diesel engine. Based on previous works on the sound propagation through DPF, in this study, losses at entrance, exit, and ceramic walls are considered and the gradients in temperature and flow velocity are considered. Transfer matrix at entrance, monolith, and exit parts are obtained by employing the segmental approach in analyzing the sound propagation through DPF. The predicted transmission loss agrees very well with the empirical one, which is measured by the improved method with correction terms.

  • PDF

CFCs 조사를 위한 지하수 시료채취방법 비교 및 평가

  • 고동찬;이대하;성현정;강철희;고경석
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.21-23
    • /
    • 2002
  • Two sampling methods for chlorofluorocarbons(CFCs) in groundwater were compared and assessed with groundwater samples in Jeju Island. CFCs concentrations from copper tube method were widely variable among triplicates and higher than those from flame-sealed glass ampule method. For the copper tube method, this is aggravated by rubber packings in the faucet of discharge line of wells, which was removed for the glass ampule method. The poor reproducibility and apparent contamination of results by copper tube method is due to the improper sealing of copper tubes and materials in water discharge line. This suggests that it is more difficult to achieve complete isolation from the atmosphere in the copper tube method and that materials that could release CFCs should be avoided along the sampling flow lines. It seems that the flame-sealed glass ampule method is more relevant for groundwater sampling for CFCs though it requires more complicated equipments and procedures.

  • PDF

압축하중을 받는 박판 4각튜브의 소성좌굴 연구 (Study on the Plastic Buckling of Thin Rectangular Tubes under Compression)

  • 김천욱;한병기;김종민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.357-362
    • /
    • 2000
  • In the present paper the plastic buckling of thin-walled rectangular tube is analyzed. The stress-strain relations of the plates of the tube are idealized into nonlinear material of Ramberg and Osgood. Computing elastic moduli of the nonlinear material a precise plastic buckling stress has determined. The plastic buckling stress of the wider plate of the tube is considered as the crippling strength of the tube. The present theory is in good agreement with the experiments in various thickness-width ratios and materials.

  • PDF

간접 광대전에 의한 서브 마이크론 입자의 단극하전 특성 (The Unipolar Charging Characteristics of Submicron Particles by Using an Indirect Photoelectric Charging)

  • 최영주;김상수
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.677-684
    • /
    • 2003
  • A new unipolar aerosol charger was developed by using an indirect photoelectric charging. The charger consists of two coaxial tubes, the inner UV lamp wrapped with stainless mesh and the outer Al cylinder. In this study, the effects of flow rate, particle size, and electric field were examined to search the optimal charging conditions with experimental and numerical methods. Monodisperse NaCl particles were fed into an annular space and the particles were charged by negative ions generated from Al plate exposed to the UV light. According to experimental results, the average number of elementary charge on particles increases from 2.5 to 5.5 as particle size increases from 50nm to 130nm at 2.5 L/min and 100V. The average number of elementary charge on particles was maximized at 25V as the electric potential between the stainless mesh and Al plate was varied from 0V to 400V.

채널형 열교환기의 성능향상에 관한 수치해석 (A Numerical Analysis for the Performance Improvement of a Channel Heat Exchanger)

  • 장병현;김시범;이권희
    • 한국기계가공학회지
    • /
    • 제11권2호
    • /
    • pp.159-164
    • /
    • 2012
  • The shell & tube heat exchanger is used throughout various industries because of its inexpensive cost and handiness when it comes to maintenance. However, it has many design elements such as the location and the shape of inlet and outlet, the numbers of tubes and baffles, etc. Also, the flow within the shell and the heat transfer are complex. This paper is performed numerical analysis to evaluate capabilities of difference in temperature and pressure drop, which are the performance of channel heat exchanger, one of different types of shell & tube exchanger. Also, factors that affect the performance of channel heat exchanger were selected through design of experiment along with key factors.

협착이 발생된 원관과 분기관내 혈액과 혈액대용유체의 정상유동해석 (Steady Flow Analyses of Blood and the Blood Analogue Fluids in the Stenosed Circular and bifurcated Tubes)

  • 유상신
    • 유변학
    • /
    • 제7권2호
    • /
    • pp.150-157
    • /
    • 1995
  • 본 논문의 목적은 협착이 발생괸 원관과 분기관내 혈액과 혈액대용유체의 유동문제 에 수치해석방법을 적용하여 유동특성을 파악하는데 있다. 혈액대용유체로서는 Separan AP-273 500wppm 수용액과 Carpobol 934 1.0w% 수용액을 사용하였다. Carbopol 수용액의 유변학적 성질은 수정멱법칙모델, 그리고 혈액과 Separan 수용액의 유변학적 성질은 Carreau 모델로 나타내었다. 협착관유동에서 Carbopol 수용액의 재부착거리는 혈액이나 Separan 수용액의 경우보다 길고 협착으로 인한 압력강하는 Carbopol 수용액, 혈액, Separan 수용액의 순으로 작게 나타난다. 분기관유동에서 Separan 수용액의 압력손실은 혈 액과 Carbopol 수용액보다 작게 나탄나고 협착이 발생괸 부기관내에서 혈액과 Separan 수 용액의 압력손실은 협착이 없는 분기관의 압력손실보다 크게 증가한다.

  • PDF

원자로 In-Core Flux Thimble 결함의 와전류 탐상 기술 개발 (Development of Eddy Current Technique for Reactor In-Core Flux Thimble Wear)

  • 박승식;장윤영;임창재;박광희
    • 비파괴검사학회지
    • /
    • 제10권2호
    • /
    • pp.15-22
    • /
    • 1990
  • Since in-core flux thimble tube wear the due to flow-induced vibration could degrade the integrity of nuclear reactor, the effective detection and interpretation of the wear is important. In order to establish an inspection technique for thimble tubes, an eddy current experiment was performed to determine the optimum test frequency, defect sensitivity and evaluation accuracy. Eddy current probes were designed and fabricated with a theory. Specimens with artificial defects were fabricated using electro discharge machining method. The results from inspection technique developed and on-site inspection showed good applicability.

  • PDF

빙축열 시스템에서의 코일 휜의 열전달 촉진 효과에 관한 실험적 연구 (An Experimental Study on tee Heat Transfer Enhancement Effect of the Coil Fins for Ice Storage System)

  • 성병호;이분희;임광빈;김철주
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2004년도 춘계 학술발표회 논문집
    • /
    • pp.219-224
    • /
    • 2004
  • The present study was to investigate the heat transfer enhancement effect of coil wire fins in an ice storage system. For the two cases of tubes with internal brine flows, a finned tube with coil wires on its outer surface and a smooth tube, the rates of ice layer were tested and compared for both the icing processes. The coil fins were made of a stainless steel wire with a dia. of 2.0(mm), and the coil had an outer dia. of 10(mm) and a helix angle of 60($^{\circ}$). The experimental results showed that the coil fins could substantially reduce the thermal resistance of the ice layer, and enhance the heat flow rates between the water in the storage tank and the brine. The ice storing time was found to be shortened by 13(%) for the coil fins to get the same amount of ice layer that was built on the smooth tube wall for 10 hours of operation when the same thermal conditions were provided.

  • PDF