• Title/Summary/Keyword: flow sensing

Search Result 286, Processing Time 0.028 seconds

A Micro-Flow Sensor With Multiple Temperature Sensing Elements for Wide Range Flow Velocity Measurement (다단계 온도 감지막을 가진 고영역 흐름측정용 마이크로 흐름센서)

  • Chung Wan-Young;Kim Tae-Yong;Seo Yong-Su
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.1
    • /
    • pp.85-92
    • /
    • 2006
  • A new silicon micro flow sensor with multiple temperature sensing elements was proposed and fabricated in considering wide range flow velocity measuring device. Thermal mass flow sensor measures the asymmetry of temperature profile around the heater which is modulated by the fluid flow. A micro mass flow sensor was normally composed of a central heater and a pair of temperature sensing elements around it. A new 2-D wide range micro flow sensor structure with three pairs of temperature sensing elements and a central heater was proposed and numerically simulated by Finite Difference Formulation to confirm the feasibility of the wide flow range sensor structure. To confirm the simulation result, the new flow sensor was fabricated on silicon substrate and the basic flow sensing properties of the sensor were measured.

Location of pressure sensing holes in MPA flowmeter and discharge coefficients (MPA 유량계 압력감지공의 위치와 유출계수)

  • Kim, Raymond K.;Choi, Sung Kil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.160-165
    • /
    • 2004
  • MPA (Multi-Point Averaging) flow element is a new type of differential pressure (DP) flow-sensing device that was developed by Seojin Instech to improve the operating characteristics of the conventional Averaging Pilot Tube (APT) flow elements. Operating characteristics of a flowmeter in general can be defined in terms of measurement accuracy and range. Improvement of accuracy and expanding the range of flow measurement were the two main objectives of the development. To achieve these dual objectives several upstream and downstream pressure-sensing holes were placed in MPA flow element. During the course of the development it was found that certain arrangements of the pressure-sensing holes improved measurement accuracy but did not expand operating flow range of Averaging Pilot Tubes. Development tests were performed with water between Reynolds number of 50,000 and 1,000,000 in the four-inch test line at the Alden Research Laboratory, U.S.A. Purpose of this paper is to present the relationship between the various locations of the pressure-sensing holes and the performance characteristics of MPA flow element. Furthermore, the operating characteristics of the best performing MPA are compared with those of typical orifice and APT.

  • PDF

A SOFT-SENSING MODEL FOR FEEDWATER FLOW RATE USING FUZZY SUPPORT VECTOR REGRESSION

  • Na, Man-Gyun;Yang, Heon-Young;Lim, Dong-Hyuk
    • Nuclear Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.69-76
    • /
    • 2008
  • Most pressurized water reactors use Venturi flow meters to measure the feedwater flow rate. However, fouling phenomena, which allow corrosion products to accumulate and increase the differential pressure across the Venturi flow meter, can result in an overestimation of the flow rate. In this study, a soft-sensing model based on fuzzy support vector regression was developed to enable accurate on-line prediction of the feedwater flow rate. The available data was divided into two groups by fuzzy c means clustering in order to reduce the training time. The data for training the soft-sensing model was selected from each data group with the aid of a subtractive clustering scheme because informative data increases the learning effect. The proposed soft-sensing model was confirmed with the real plant data of Yonggwang Nuclear Power Plant Unit 3. The root mean square error and relative maximum error of the model were quite small. Hence, this model can be used to validate and monitor existing hardware feedwater flow meters.

Environmental Monitoring Using Comfort Sensing System

  • Na, Dae-Suk;Kang, Jeong-Ho;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.24-33
    • /
    • 2003
  • This research is about a comfort sensing system for human environmental monitoring using a one-bodied humidity and temperature sensor and an air flow sensor. The thermal comfort that a human being feels in indoor environment has been known to be influenced mostly by six parameters, i.e. air temperature, radiation, air flow, humidity, activity level and clothing thermal resistance. Considering an environmental monitoring, we have designed and fabricated a one-bodied humidity and temperature sensor and an air flow sensor that detect air relative humidity, temperature and air flow in human environment using surface micromachining technologies. Micro-controller calculates a PMV (predicted mean vote) and CSV (comfort sensing vote) with sensing signals and display a PMV on LCD (liquid crystal display) for human comfort on indoor climate. Our work has demonstrated that a comfort sensing system can provide an effective means of measuring and monitoring the indoor comfort sensing index of a human being. Experimental results with simulated environment clearly suggest that our comfort sensing system can be used in many applications such as air conditioning system, feedback controlling in automobile, home and hospital etc..

Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones (다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서)

  • Lee Dong Woo;Yi Soyeon;Cho Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

Sensing Technologies for Grain Crop Yield Monitoring Systems: A Review

  • Chung, Sun-Ok;Choi, Moon-Chan;Lee, Kyu-Ho;Kim, Yong-Joo;Hong, Soon-Jung;Li, Minzan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.408-417
    • /
    • 2016
  • Purpose: Yield monitoring systems are an essential component of precision agriculture. They indicate the spatial variability of crop yield in fields, and have become an important factor in modern harvesters. The objective of this paper was to review research trends related to yield monitoring sensors for grain crops. Methods: The literature was reviewed for research on the major sensing components of grain yield monitoring systems. These major components included grain flow sensors, moisture content sensors, and cutting width sensors. Sensors were classified by sensing principle and type, and their performance was also reviewed. Results: The main targeted harvesting grain crops were rice, wheat, corn, barley, and grain sorghum. Grain flow sensors were classified into mass flow and volume flow methods. Mass flow sensors were mounted primarily at the clean grain elevator head or under the grain tank, and volume flow sensors were mounted at the head or in the middle of the elevator. Mass flow methods used weighing, force impact, and radiometric approaches, some of which resulted in measurement error levels lower than 5% ($R^2=0.99$). Volume flow methods included paddle wheel type and optical type, and in the best cases produced error levels lower than 3%. Grain moisture content sensing was in many cases achieved using capacitive modules. In some cases, errors were lower than 1%. Cutting width was measured by ultrasonic distance sensors mounted at both sides of the header dividers, and the errors were in some cases lower than 5%. Conclusions: The design and fabrication of an integrated yield monitoring system for a target crop would be affected by the selection of a sensing approach, as well as the layout and mounting of the sensors. For accurate estimation of yield, signal processing and correction measures should be also implemented.

Effects of Flow Rates and CS Factors on TOF MRA using Compressed Sensing (Compressed sensing을 이용한 TOF MRA 검사에서 Flow rate와 CS factor의 변화에 따른 영향)

  • Kim, Seong-Ho;Jeong, Hyun-Keun;Yoo, Se-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.281-291
    • /
    • 2021
  • This study aimed to measure the quantitative changes in images according to the use of compressed sensing in expressing the slow flow rate in TOF MRA test using magnetic resonance imaging. This study set different blood flow rate sections by using auto-injector and flow phantom and compared changes in the SNR, CNR, SSIM, and RMSE measurements by different CS factors between TOF with CS and TOF without CS. One-way ANOVA was performed to test the effect on the image induced by the increase of the CS factor. The results revealed that TOF MRA with CS significantly decreased scan time without significantly affecting SNR and CNR compared to TOF MRA with CS. On the other hand, the differences in SSIM and RMSE between TOF with CS and TOF without CS increased as the CS factor increased. Therefore, it is necessary to efficiently reduce scan time by adapting the CS technique while considering the appropriate range of the CS factor. Additionally, more studies are needed to evaluate CS factors and the similarity precision of images further.

Development of a Debris Flow Sensing Device and Real Time Warning System (토석류 감지장치 개발과 실시간 경보체계 구축 사례)

  • Kim, Kyung-Suk;Jang, Hyun-Ick;Chung, Sung-Yun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.273-280
    • /
    • 2008
  • Debris flow has been considered as one of the major natural hazards and possesses tens to hundreds times higher destructive potential than that of slope failure. In the past 5 years, its occurrence frequency was and is likely to increasing due to the global warming. Although various methods such as basin vegetation or structural dams can be implemented to counter measure the debris flow, these methods are not always the right answer to the problem when magnitude of debris flow is far bigger than could be defended. Land use regulations to avoid the hazard or early debris flow warning system to evacuate the expected inundated area can be more economical and practical actions for those cases. In this study, an early debris flow warning system composed of rainfall measuring device, debris flow sensing device and video camera is introduced. The system is designed to issue the warning when rainfall threshold is exceeded or debris flow is sensed by sensing device. Developed monitoring system can be used to cope promptly with the debris flow risk.

  • PDF

Research on Improvement of Performance of Anemometer Using PTC Thermistor (PTC 서미스터를 이용한 유속계의 성능향상에 관한 연구)

  • Yoon, Joon-Yong;Cho, Nahm-Gyoo;Kim, Jin-Rae;Sung, Nak-Won;Kim, Hwang-Jin
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.15-21
    • /
    • 2000
  • An anemometer employing the bulk PTC thermistor as the sensing element is investigated in this study. The numerical and experimental works are carried out to improve the sensitivity problem of the element by focusing fluid dynamics point of view. The typical shape of the sensing element has been used as a rectangular type, but this shape has a sensitivity problem because of flow separations on the sharp edge when the flow direction is different from that of the sensing element. In order to reduce the reading error, the installer has to be very careful about the flow direction. The reading error fluctuation by time as well as the sensitivity problem can be improved considerably through this study. It can be concluded that the small change of the sensor shape can improve the performance of the flow sensor.

  • PDF

Dynamic Load-Balancing Algorithm Incorporating Flow Distributions and Service Levels for an AOPS Node

  • Zhang, Fuding;Zhou, Xu;Sun, Xiaohan
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.466-471
    • /
    • 2014
  • An asynchronous optical packet-switching (AOPS) node with load-balancing capability can achieve better performance in reducing the high packet-loss ratio (PLR) and time delay caused by unbalanced traffic. This paper proposes a novel dynamic load-balancing algorithm for an AOPS node with limited buffer and without wavelength converters, and considering the data flow distribution and service levels. By calculating the occupancy state of the output ports, load state of the input ports, and priorities for data flow, the traffic is balanced accordingly. Simulations demonstrate that asynchronous variant data packets and output traffic can be automatically balanced according to service levels and the data flow distribution. A PLR of less than 0.01% can be achieved, as well as an average time delay of less than 0.46 ns.