• 제목/요약/키워드: flow rate calculation method

검색결과 153건 처리시간 0.028초

고속 전철용 매입형 영구자석 전동기의 풍량에 따른 열해석 (Thermal Analysis of Traction Motor in the High Speed Train with various Flow Rate)

  • 임재원;이경표;정현교
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.165-170
    • /
    • 2010
  • Recently, Interior Permanent Magnet Machine(IPM) is widely used for traction motor in the high speed train. Higher efficiency and power density are the superb performance of IPM. Due to the high power density, however, it has lots of heat source which are originated from copper losses and core losses. These heat source can cause the permanent demagnetization in magnet and the loss of torque and power. To prevent the undesirable loss in the traction motor, the accurate loss calculation and the thermal analysis should be preceded. Especially, the end-winding area and permanent magnet area should be examined correctly. In this paper, the electromagnetic fields were examined by finite element method to analyze the electromagnetic properties of IPM and thermal analysis are carried out with pre-calculated losses. To validate the analysis result, the experiment set with forced air cooling system is manufactured.

  • PDF

축류홴의 설계 변수가 홴의 성능과 소음에 미치는 영향의 수치적 연구 (A Numerical Study on the Effects of the Design Parameters upon Fan Performance and Noise)

  • 전완호;백승조;김창준;윤홍열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.264-269
    • /
    • 2001
  • Axial fans are widely used in household electrical appliances due to their easy usage and high flow rate for cooling capacity. At the same time, the noise generated by these fans causes one of serious problems. In order to calculate the noise of a fan, we develop the software IFD - Intranet Fans Design. With this software we can design, analysis the performance and predict the noise of fan. The prediction model, which allowed the calculation of acoustic pressure at the blade passing frequency and it's higher harmonic frequencies, has been developed by Lowson's equation. To calculate the unsteady resultant force of the blade, time-marching free-wake method is used. The objective of this study is to calculate the effects of number of blades, rotating velocity, and sweep angle on the noise of fan..

  • PDF

중장비 축류홴 저소음화 기법 (Low Noise Techique of Axial Fan in Heavy Equipments)

  • 정기훈;최한림;김용제;이덕주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.388-395
    • /
    • 2000
  • Axial fans are widely used in heavy machines due to their ability to produce high flow rate for cooling of engines. At the same time, the noise generated by these fans causes one of the most serious problems. This work is concerned with the low noise technique of discrete frequency noise. The prediction model, which allowed the calculation of acoustic pressure at the blade passing frequency and it's harmonics, has been developed by Farrasat. This theory is founded upon the acoustic radiation of unsteady forces acting on blade. To calculate the unsteady resultant force over the fan blade. Time-Marching Free-Wake Method are used. The ideas of low noise technique are obtained from Blade-Momentum Methods. In this paper, the discussion is confined to the performance and discrete noise of axial fan in heavy equipments.

  • PDF

압력제어용 직동 밸브를 이용한 전기.유압 서보시스템의 힘 제어 (Force Control of Electro-Hydraulic Servo System using Direct Drive Valve for Pressure Control)

  • 이창돈;이진걸
    • 유공압시스템학회논문집
    • /
    • 제1권3호
    • /
    • pp.14-19
    • /
    • 2004
  • The Direct Drive Valve used in this study contains a pressure-feedback-loop in itself, then it can eliminate nonlinearity such as the square-root-term in flow rate calculation and the change of bulk modulus of hydraulic oil. In this study, assuming that the dynamic characteristic of the DDV is modelled as a first order lag system, an parameter identification method using the input data and the output data is applied to obtain DDV's mathematical model. Then, a state feedback controller was designed to implement the force control of hydraulic system, and the control performance was evaluated.

  • PDF

임펠러 형상변수가 원심펌프 성능에 미치는 영향 (Effect of impeller geometrical parameter on the performance of a centrifugal)

  • 김성;최영석;김준형;윤준용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1303-1308
    • /
    • 2008
  • This paper presents effects of impeller geometrical parameters on the performance of a centrifugal pump impeller. The effects of meridional parameters and vane plane development parameters on the performance of the impeller were numerically studied using a commercial CFD code and DOE(design of experiments) software. Geometrical parameters in a method of meridional view and vane plane development were selected and defined to generate the 3D impeller shape. The response variables are defined in a total head and efficiency curve with flow rate. The influences of selected design variables on the various objective functions were examined as a result of the calculation using 2k factorial.

  • PDF

Matlab GUI를 활용한 Gerotor 치형 설계 도구 개발 (Design Tool Developments of the Gerotor tooth using Matlab GUI)

  • 장주섭
    • 유공압시스템학회:학술대회논문집
    • /
    • 유공압시스템학회 2010년도 춘계학술대회
    • /
    • pp.25-32
    • /
    • 2010
  • A geortor type pump is widely used in lubrication and actuator systems. Especially the pump is an essential machine element of an automotive engine to feed lubrication oil and power source of automatic transmission. A gerotor is a planar mechanism consist of a pair of rotor and circular tooth of stator assembly which forms a closed space. However, related industries do not have necessary technology to design and optimize the pump and paid royalties of gerotor profile on an advanced company. Also, gerotor profiles with setting design parameter have not been sufficiently analyzed from a theoretical view. Therefore, it is very difficult for designer to decide the specifications of the gerotor profiles, and calculation and fluctuation of flow rate is not yet confirmed. In this study, theoretical analyses and optimal design of the gerotor profiles have been performed numerical method by mathematical base. An automated design system of the tooth profile has been developed through MATLAB GUI Program considering various design parameters.

  • PDF

비균일 입류에 의한 팬소음 해석 (Analysis of Non-Uniform Inflow Fan Noise)

  • 정기훈;최한림;윤용일;이상현;이덕주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.106-112
    • /
    • 2000
  • Axial fans are widely used in heavy machines due to their ability to produce high flow rate for cooling of engines. At the same time. the noise generated by these fans causes one of the most serious problems. This work is concerned with the low noise technique of discrete frequency noise. The prediction model. which allowed the calculation of acoustic pressure at the blade passing frequency and it's harmonics. has been developed by Farrasat. This theory is founded upon the acoustic radiation of unsteady forces acting on blade. To calculate the unsteady resultant force over the fan blade. Time-Marching Free-Wake Method are used. The fan noise of fan system having unsymmetric engine-room is predicted. In this paper, the discussion is confined to the performance and discrete noise of axial fan and front part of engine room in heavy equipments.

  • PDF

원자력 발전소에 대한 밀폐 ${CO}_{2}$ 가스터빈 프로세스의 최적화 연구 (II) -열교환기의 설계에 관하여 - (A Study of th Optimum of closed ${CO}_{2}$ Gas Turbine Process for Nuclear Energy Power Plant(II) - For Optimal Design of Heat Exchanger-)

  • 이찬규;이종원
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.251-258
    • /
    • 1990
  • 본 연구에서는 제 1보에서 다루었던 프로세스 해석의 결과들을 토대로 하여 열교환기의 최적 설계를 행하는데 주력하였다. 먼저, 열교환기의 최적 설계를 행하 는데 주력하였다. 먼저, 열교환기의 열설계에 필요한 CO$_{2}$와 Natrium의 물성치 및 열전달에 관한 기존의 실험식들을 여러문헌으로부터 연구 검토한 후 프로그램에 편 리하게 이용할 수 있도록 전산화 하였으며, 열교환기의 설계시 필요한 전체 경비의 최 소화를 기하는 방향으로 최적화된 설계인자들을 결정하도록 시도하였고 또한 최적화된 프로그램을 개발함으로써 인력, 외화 및 에너지 절감의 효과를 얻고자 하였다.

HPLC-ICP/MS에서 후 컬럼 동위원소 희석법의 기초적인 불확도 연구 (A short study of uncertainty for post column isotope dilution method in HPLC-ICP/MS)

  • 주민규;박용남
    • 분석과학
    • /
    • 제27권6호
    • /
    • pp.269-276
    • /
    • 2014
  • 후 컬럼 동위원소 희석법의 불확도를 HPLC-ICP/MS에서 Selenomethionine을 분석할 경우에 대하여 간단히 연구하였다. 주요하다고 생각한 오차의 원인으로 셀레늄 동위원소 용액의 농도와 흐름속도, 스파이크 용액과 시료 용액에서의 셀레늄 원자량, 그리고 스파이크된 시료용액에서 측정된 동위원소의 비를 선택하였다. 각 요인에 따른 불확도를 구하고 전체 농도의 불확도에 미치는 요인을 계산한 결과, 각각에 대하여 54.4%와 0.61%, 0.0072%와 0.018%, 그리고 45.0%를 얻었다. 가장 큰 요인은 스파이크 동위원소 용액의 농도이며 두 번째는 스파이크가 첨가된 시료용액에서의 동위원소비이었다. 스파이크 용액의 질량흐름속도와 원자량의 불활도는 크게 영향을 끼치지 못하였다. 계산된 전체불확도는 $126.30ng{\cdot}g^{-1}$ SeMet 표준용액에 대하여 $1.46ng{\cdot}g^{-1}$으로서 실험결과는 $127.09ng{\cdot}g^{-1}$을 얻었고 상대불확도는 1.20%이었다.

A Study on Development of a Plugging Margin Evaluation Method Taking Into Account the Fouling of Shell-and-Tube Heat Exchangers

  • Hwang, Kyeong-Mo;Jin, Tae-Eun;Kim, Kyung-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제20권11호
    • /
    • pp.1934-1941
    • /
    • 2006
  • As the operating time of heat exchangers progresses, fouling caused by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of Korean nuclear power plants have been analyzed in terms of heat transfer rate and overall heat transfer coefficient as a means of heat exchanger management. Except for fouling resulting from the operation of heat exchangers, all the tubes of heat exchangers have been replaced when the number of plugged tubes exceeded the plugging criteria based on design performance sheet. This paper describes a plugging margin evaluation method taking into account the fouling of shell-and-tube heat exchangers. The method can evaluate thermal performance, estimate future fouling variation, and consider current fouling level in the calculation of plugging margin. To identify the effectiveness of the developed method, fouling and plugging margin evaluations were performed at a component cooling heat exchanger in a Korean nuclear power plant.