• 제목/요약/키워드: flow meter

검색결과 595건 처리시간 0.026초

냉장고용 왕복동 압축기 급유 시스템의 수치해석 (Numerical Simulation of Oil Supply System of Reciprocating Compressor for Household Refrigerators)

  • 김현진;이진갑
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.24-30
    • /
    • 2005
  • For a reciprocating compressor of household refrigerators, a direct analogy between the pipe flow network and the electric circuit network has been utilized to set up a mathematical model for oil supply system. Individual lubrication elements of the oil supply system, such as propeller- installed oil cap, oil galleries, radial oil feeding holes, spiral oil grooves, and various sliding surfaces have been analogized by equivalent electric elements, and these have been combined together to form an electric circuit corresponding to the whole oil supply system. By solving the closed network equations of the model, oil flow rates at various lubrication elements could be obtained. Total amount of the oil flow rate drawn into the shaft has been measured and compared reasonably well with the prediction of the numerical simulation.

  • PDF

개방형 원심회전차의 내부유동장에 관한 실험적 연구(1)-무충돌 유입조건에서- (Experimental Study on Flows within an Unshrouded Centrifugal Impeller Passage(I)-At the Shockless Condition-)

  • 김성원;조강래
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2261-2270
    • /
    • 1995
  • Flow patterns were measured in an unshrouded centrifugal impeller. The flow rate in measurements was fixed at the value corresponding to a nearly zero incidence at the blade inlet. By using a single slanted hot-wire probe and a Kiel probe mounted on the impeller hub disk, the 3-D relative velocities and the rotary stagnation pressures were measured in seven circumferential planes from the inlet to the outlet of the impeller rotating at 700rpm, which diameter is 0.39 meter, and the static pressures and the slip factor at the impeller outlet were calculated from the measured values. From the measured data, the primary/secondary flows, the leakage flows, the wake-jet flows, static pressure distribution on blade surfaces and the wake production mechanism in the impeller passage were investigated.

열선을 이용한 혼합기체의 농도와 유량의 측정 (Measurement of Gas Concentration and flow Rate Using Hot Wire)

  • 김영한;최종정
    • 제어로봇시스템학회논문지
    • /
    • 제8권5호
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.47-51
    • /
    • 2015
  • We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

횡단 유동장의 기액비 및 레이놀즈수 변화에 따른 외부혼합형 이상유체 제트의 액적크기 및 체적유속 특성 (Characteristics of SMD and Volume Flux of Two-phase Jet Injected into Cross-flow with Various Gas-liquid Ratio and Reynolds Number)

  • 김종현;이봉수;구자예
    • 한국자동차공학회논문집
    • /
    • 제17권2호
    • /
    • pp.75-81
    • /
    • 2009
  • A study was performed to investigate the characteristics of two-phase jet injected into subsonic cross-flow using the external mixed gas blast two-phase nozzle. The shadowgraph method was adopted for the cross-flow jet visualization and PDPA system was used to measure droplet size, velocity, and volume flux. The atomization of two-phase jet is initially determined according to gas to liquid mass flow-rate ratio and the Reynolds number of cross-flows. The highest penetration trajectories of two-phase jet injected into cross-flow are governed by the momentum ratio at subsonic cross-flow. As GLR of two-phase jet injected into cross-flow increases, the droplet size decreases and the distribution area of volume flux increases. The distribution of volume flux that influenced by the counter vortex pair at the downstream of cross-flow is symmetric in shape of horseshoe.

Experimental and Computational Studies on Flow Behavior Around Counter Rotating Blades in a Double-Spindle Deck

  • Chon, Woo-Chong;Amano, Ryoichi S.
    • Journal of Mechanical Science and Technology
    • /
    • 제18권8호
    • /
    • pp.1401-1417
    • /
    • 2004
  • Experimental and computational studies were performed to determine the effects of different blade designs on a flow pattern inside a double-spindle counter rotating mower deck. In the experimental study, two different blade models were tested by measuring air velocities using a forward-scatter LDV system. The velocity measurements were taken at several different azimuth and axial sections inside the deck. The measured velocity distributions clarified the air flow pattern caused by the rotating blades and demonstrated the effects of deck and blade designs. A high-speed video camera and a sound level meter were used for flow visualization and noise level measurement. In the computational works, two-dimensional blade shapes at several arbitrary radial sections have been selected for flow computations around the blade model. For three-dimensional computation applied a non-inertia coordinate system, a flow field around the entire three-dimensional blade shape is used to evaluate flow patterns in order to take radial flow interactions into account. The computational results were compared with the experimental results.

Assessment of environmental flows using hydrological methods for Krishna River, India

  • Uday Kumar, A.;Jayakumar, K.V.
    • Advances in environmental research
    • /
    • 제7권3호
    • /
    • pp.161-175
    • /
    • 2018
  • Krishna River is significantly affected due to Srisailam dam from past 30 years. The impact of this hydraulic structure drastically reduced the minimum flow regime on the downstream, which made the river nearing to decaying stage. In the present paper, Environmental Flow called minimum flow values released for the dam are estimated with the help of three hydrological methods viz., Range of variability Approach (RVA), Desktop Reserve Model (DRM), and Global Environmental Flow Calculator (GEFC). DRM method suggested considering the intermediate values obtained from among the three methods to preserve the ecosystem on the downstream of the river, which amounts to an average annual allocation of 9378 Million Cubic Meter (MCM) which is equal to 23.11% of mean annual flow (MAF). In this regard GEFC and RVA methods accounted for 22% and 31.04% of MAF respectively. The results indicate that current reservoir operation policy is causing a severe hydrological alteration in the high flow season especially in the month of July. The study concluded that in the case of non-availability of environmental information, hydrological indicators can be used to provide the basic assessment of environmental flow requirements. It is inferred from the results obtained from the study, that the new reservoir operations can fulfil human water needs without disturbing Environmental Flow Requirements.

자동화 그라우팅 기법의 현장적용성에 관한 연구 (A Study on the Field Application of Automatic Grouting System)

  • 도종남;박정환;최동찬;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제13권1호
    • /
    • pp.63-74
    • /
    • 2012
  • 국내에서 그라우팅은 대부분 전문성 있는 지식이나 이론적인 연구에 의한 방법이 아닌 경험적인 방법에 의해 설계되고 있다. 따라서, 본 연구에서는 그라우팅이 적용되는 건설현장에서 자동화 그라우팅 기법의 품질관리기술과 방법에 대한 것을 논의하고자 한다. 연구결과, 제한적인 물주입시험에 의한 최적주입압 결정과 관련된 방법은 그라우팅 전.후에 대한 평가만이 가능한 것으로 나타났으며, 그라우팅재료가 지반내에서 확산하는 동안 주입압력(p)~주입속도(q)~침투시간(t) 차트 분석을 통해 주입압, 주입속도, 침투시간의 특성을 평가할 경우 그라우트 압력에 의한 지반의 파쇄를 방지할 수 있을 것으로 나타났다. 주입압력(p), 주입속도(q)와 침투시간(t) 곡선을 분석하여 적합한 값을 도출하면 효과적인 설계를 수행할 수 있다. 본 차트분석기법은 기존의 종이롤에 기록되어 지는 주입압력(p)과 주입속도(q)를 정리하여 관리할 수 있으며, 통합유량계는 정확한 수량을 기록할 수 있으나 기록된 주입압력은 초기, 중급 및 최종 지점에 따라 다르게 나타나므로, 통합유량계 및 그라우팅 대상 지반의 특성의 상관관계가 규명되는 것이 바람직한 것으로 사료된다, 본 연구에서 제안된 자동화 그라우팅 기법은 주입압력과 그라우팅 대상 지반의 특성간의 신뢰성 있는 상관관계를 설명할 수 있으며, 이를 활용한 그라우팅 품질관리 기술을 발전시킬 것으로 기대된다.

수소 충전소 계량오차 검증 설비 설치를 위한 위험성 분석 사례 연구 (A Case Study on the Risk Analysis for the Installation of Measurement Error Verification Facility in Hydrogen Refueling Station)

  • 이화영;장현우;이민경;김정환;이재훈
    • 한국가스학회지
    • /
    • 제26권6호
    • /
    • pp.30-36
    • /
    • 2022
  • 수소 충전소를 이용한 에너지원의 상거래에 있어 부정확한 계량에 의한 과 충전 등의 사고 예방과 정확한 계량을 통한 수소 상거래의 투명성 확보를 위해서는 높은 정확도의 유량계가 필요하다. 본 연구에서는 코리올리 방식 유량계 시작품을 개발하였으며, 계량 성능 검증을 위하여 기존에 운영 중인 충전소를 대상으로 공정변경을 통한 계량 성능 비교 실험 중 발생할 수 있는 사고의 예방을 위하여 위험성 평가를 수행하였다. 실증실험용 계량설비 설치를 위한 공정 변경 구간을 정의하고 HAZOP을 실시하였다. 또한 실증 실험 중 밸브오 개방 예방 등 실험자 안전성 확보를 위한 JSA도 병행하였다. HAZOP을 통하여 도출된 위험 요소를 개선하기 위한 방안을 수립하였으며 JSA를 통해 인적오류를 최소화하고 작업자의 안전성 확보할 수 있는 작업 절차를 수립하였다. 이와 같은 위험성 평가 결과를 반영하여 계량시스템 설치를 위한 설계 변경 및 시스템 제작을 완료하였으며 개발된 계량기 시작품의 성능비교 실험을 통해 안전성을 확인할 수 있었다. 개발된 시작품 유량계는 70MPa의 운전 조건에서 총 30회 유량 측정 실험 결과 평균 오차는 -1.58% ~ 3.96%로 나타났다. 이와 같은 계량오차는 상업용으로 설치 운영 중인 유량계와 동등 수준의 성능을 가진 것으로 분석되었다.

이산화탄소가 수소 산소부화 화염의 열전달에 미치는 영향 (Effects of CO2 on Heat Transfer from Oxygen-Enriched Hydrogen Flame)

  • 이창엽;최준원;백승욱
    • 대한기계학회논문집B
    • /
    • 제28권8호
    • /
    • pp.937-944
    • /
    • 2004
  • An experimental study has been conducted to evaluate the effects of $CO_2$ on heat transfer from oxygen-enriched hydrogen flame. Experiments were performed on flames stabilized by a co-flow swirl burner, which was mounted on top of the furnace. Five different oxidizer compositions were prepared by replacing $N_2$ with $CO_2$. In a steady state, the total as well as radiative heat flux from the flame to the wall of furnace have been measured using a heat flux meter. Temperature distribution in furnace also has been measured and compared. By increasing $CO_2$ proportion in the oxidizer, the convection played a more significant role rather than radiation. Overall temperature in the furnace was seen to be decreased, while the total heat flux has increased.