• Title/Summary/Keyword: flow meter

Search Result 596, Processing Time 0.03 seconds

Numerical investigation of the large over-reading of Venturi flow rate in ARE of nuclear power plant

  • Wang, Hong;Zhu, Zhimao;Zhang, Miao;Han, Jinlong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.69-78
    • /
    • 2021
  • Venturi meter is frequently used in feed water flow control system in a nuclear power plant. Its accurate measurement plays a vital role in the safe operation of the plant. This paper firstly investigates the influence of the length of each section of pipeline, the throat inner diameter of Venturi and the flow characteristics in a single-phase flow on the accuracy of Venturi measurement by numerical calculation. Then the flow and the accuracy are discussed in a multi-phase flow. Numerical results show that the geometrical parameters and the characteristics of complex turbulent flow in the single-phase flow have little impact on the accuracy of Venturi flow rate measurement. In the multi-phase flow, the calculated flow rate of Venturi deviated from the actual flow rate and this deviation value is closely related to the amount of steam in the pipeline and increases sharply with the increase of the amount of steam. The over-reading of Venturi flow rate is present.

Implementation of a Mixing-Ratio Control System for Two-Component Liquid Silicone Mixture (이액형 액상실리콘 재료의 혼합비율 제어 시스템 개발)

  • Choo, Seong-Min;Kim, Young-Min;Lee, Keum-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.688-694
    • /
    • 2018
  • The mixture ratio of two-component liquid silicone is important for the inherent physical characteristics of the finished product. Therefore, it is necessary to uniformly control the ratio of the main material and the sub-material. In this paper, a mixing-ratio control system was designed, which consists of a digital flow meter and a flow control system to measure the flow rate of the raw materials and a pumping system to maintain constant pressure and transfer of the raw materials. In addition, a program was developed to control the organic interlocking and mixing ratio. For the verification of the developed system, we compared the actual weight of raw material with the value measured by the flow meter during pumping, and we measured the physical properties of the mixed material by making test samples with and without the application of the mixing-ratio improvement algorithm. The measured value was close to the reference value with a hardness range of 46-47 and tensile strength of 9.3-9.5 MPa. These results show that the mixing ratio of the liquid silicone is controlled within an error range of ${\pm}0.5%$.

Estimation of the Possible Age for Using Various Types of Inhaler by In-Check Inspiratory Flow Meter(TM) (In-Check Inspiratory Flow Meter(TM)를 사용하여 추정한 다양한 흡입기구의 사용 가능한 연령)

  • Jung, Kyung Hyun;Kim, Sun Ye;Lee, Jun Ho;Kim, Kye Sung;Jang, Yook;Han, Man Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.192-198
    • /
    • 2002
  • Purpose : It is important to select and use kinds of Inhaler appropriate to the age of the patient and severity of symptoms. Several kinds of Inhaler have been developed and recommended according to each inhaler's resistance and usage method. We evaluated the usable age of 4 inhalers (turbulent flow inhalers, multi unit dose inhalers, breath actuated MDI, and autohalers) by measuring peak inspiratory flow(PIF) using $In-Check^{(TM)}$ Inspiratory Flow Meter. Methods : Ninety three patients aged from 3 to 7 years(mean $57{\pm}12.9$ mo.) who had admitted to CHA hospital from July 2000 to April 2001 were enrolled. Study patients were divided into 4 groups according to age : 3-4 years of age(group A, n=31), 4-5 years of age(group B, n=32), 5-6 years of age(group C, n=18), and 6-7 years of age(group D, n=12). Results : Out of total 93 patients, 23(71%), 27(84%), 17(94%) patients of each group A, B, C and all 12 patients of group D could use the 4 types of inhaler through adequated education. In all four groups, height, body weight and age were significantly correlated(P<0.05). Usable age, height and weight of children who can use turbulent flow inhaler(TFI) were each 8 year 7 month old, 144 cm, 32.0 kg, and those of multi unit dose inhaler(MUD) were 2 year 10 month old, 92 cm, 12.0 kg. Also that of breath-actuated MDI were 1 yr 8 months, 83 cm, 8.5 kg and that of autohaler were 2 yr 8 months, 91 cm, 11.0 kg Conclusion : We concluded that the ability to use inhalers correlated with height, weight and age of the patients. Multi unit dose inhalers, Breath actuated MDI and Autohaler are useful after 3 years of age through adequate education.

Development of Differential Exhaust Flow Controller using One Chip Microcontroller (단일칩 마이크로컨트롤러를 이용한 차압식 유량제어기의 개발)

  • Park, Chan-Won;Kim, Hyun-Sik;Joo, Yong-Kyu
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.89-94
    • /
    • 2002
  • In this paper, a Exhaust Flow Controller (EFC) technology for uniform application of film coater and developer device is introduced that spread and remove photo resister at semiconductor manufacturing process. Because developed EFC device uses differential pressure sensing method as a differential flow meter and embodied smart A/D conversion by using a one chip microprocessor and devised by feedback Servo control, It has shown excellent performance and stability evaluation, as maximum 2000L/min flow, capability of installation to actual semiconductor equipment.

  • PDF

Three-Dimensional Flow Analysis for Estimation of Measuring Error oi Orifice Flowmeter due to Swirling Flow (선회로 인한 오리피스 유량계의 계량오차 예측을 위한 삼차원 유동해석)

  • Kim Hong-Min;Kim Kwang-Yong;Her Jae-Young;Ha Young-Chul
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.79-82
    • /
    • 2002
  • Three-dimensional pipe flows with elbows and tees for few different pipe fittings are calculated to estimate the effect of swirling flow on measuring accuracy of orifice flow meter. It is evaluated how the pressure difference across the orifice is dependent on the length of upstream straight pipe in a branch and how swirl intensity, swirl angel and axial velocity distribution affect the measuring error of orifice flowmeter. From the results, it is found that, regardless of flow rate specified in this calculation, the effect of the straight pipe length can be neglected for the lengths larger than thirty diameters although there still remain significant swirl at the orifice

  • PDF

Enhancement of Oxygen Transfer Efficiency Using Vibrating lung Assist Device in In-Vitro Fluid Flow (In-vitro 유동장에서 진동형 폐 보조장치를 이용한 산소전달 효율의 향상)

  • 권대규;김기범;이삼철;정경락;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1332-1335
    • /
    • 2003
  • This paper presents the enhancement of oxygen transfer efficiency using the vibrating intravascular lung assist device (VIVLAD) in in-vitro experiments for patients having chronic respiratory problems. The test section was a cylinder duct with the inner diameter of 30 mm. The flow rate was controlled by the pump and monitored by a built-in flow meter. The vibration apparatus was composed of a piezo-vibrator, a function generator. and a power amplifier. The direction of vibration was radial to the fluid flow. Gas flow rates of up to 6 l/min through the 120-cm-Jong hollow fibers have been achieved by exciting a piezo-vibrator. The output of PVDF sensor were investigated by various frequencies in VIVLAD. The experimental results showed that VIVLAD would be enhance oxygen transfer efficiency.

  • PDF

ESTIMATION OF PEDESTRIAN FLOW SPEED IN SURVEILLANCE VIDEOS

  • Lee, Gwang-Gook;Ka, Kee-Hwan;Kim, Whoi-Yul
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.330-333
    • /
    • 2009
  • This paper proposes a method to estimate the flow speed of pedestrians in surveillance videos. In the proposed method, the average moving speed of pedestrians is measured by estimating the size of real-world motion from the observed motion vectors. For this purpose, pixel-to-meter conversion factors are calculated from camera geometry. Also, the height information, which is missing because of camera projection, is predicted statistically from simulation experiments. Compared to the previous works for flow speed estimation, our method can be applied to various camera views because it separates scene parameters explicitly. Experiments are performed on both simulation image sequences and real video. In the experiments on simulation videos, the proposed method estimated the flow speed with average error of about 0.1m/s. The proposed method also showed a promising result for the real video.

  • PDF

A Design Traffic Conditioner for Fairness Resource share in Differentiated Service (Differentiated Service에서 공정한 자원 공유를 위한 Traffic Conditioner 설계)

  • 이진호;김용수;장경성;김병기
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.04a
    • /
    • pp.310-312
    • /
    • 2000
  • 명시적인 자원 할당과 스케줄링에 의해 QoS를 제공 할 수 있는 방안으로 RSVP가 제안되었으나 내부 구조 변경이나 확장성의 문제를 내포하고 있다. 그래서 IETF에서는 차등 서비스(Differentiated Service)를 이용하여 서비스 영역을 확장하려는 연구가 활발히 진행중이다. DiffServ는 확장성을 고려하여 RSVP와 같은 개별 flow에 대한 QoS 제공이 아닌 flow들의 집합(aggregated)으로 차등적인 서비스를 제공하는 방법이다. 본 논문에서는 aggregated flow로 서비스를 제공할 때 불특정 flow에 대한 QoS 손실을 막기 위해 Token Bucket Meter 처리 전에 사전 모니터링에 의해 자원공유의 공정성과 처리 속도를 향상시킬 수 있는 TC(Traffic Conditioner)를 설계, 구현하여 다수 subnetwork에서의 flow가 자원을 공정하게 공유함을 결과로 보였다.

  • PDF