• Title/Summary/Keyword: flow level

Search Result 4,356, Processing Time 0.036 seconds

Efficiency Study of Measurement Method by Flow Duration (유황별 유속측정 방법에 따른 유효성 연구)

  • Ham, Sang In;Lee, Jeong Hwan;Kim, Dae Young;Ha, Don Woo;Kim, Yoon Soo;Jung, Kang-Young;Lee, Yeong Jae;Kim, Gyeong Hyeon;Kim, Young Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.5
    • /
    • pp.462-469
    • /
    • 2018
  • There are differences in method and cycle of flow rate survey depending on purpose of the operating department. To verify and use results of flow data according to the purpose, flow data of the directly measured and tele monitoring system were compared to verify validity. Flow measurement in the Ministry of Environment is aimed at setting up a standard flow of target water quality for water quality management and securing flow data of low and normal water level seasons for water quality evaluation. In this study, correlation analysis result ($R^2$) of same time zone data by direct measurement and tele monitoring system (TMS) at Seombon D point, a unit watershed of Seomjin river, for six years ('10 ~ '15) according to implementation of Total Daily Maximum Load (TDML) was wading 0.716, boating 0.962 and on bridge 0.943, and effectiveness of measurement method was verified by characteristics of flow duration as a season of dry and low-water; normal and high water are appropriate for wading, boating, and on bridge respectively. Results revealed it is reasonable to use directly measured results using the wading and boating method for low water level and dry seasons, and TMS data for rainy seasons. It can be used important data for future policy decisions.

Integrative Literature Review of Flow Experience and Intrinsic Motivation Decrease (운동몰입의 경험과 내적동기 저하에 관한 고찰)

  • Jung Min Son;Min-Seong Ha;Minchul Lee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.1001-1009
    • /
    • 2023
  • Flow is a concept closely related to intrinsic motivation and is considered a positive factor in sports performance in sports psychology. The purpose of this study was to confirm the addictive nature of Flow through previous studies and propose a new hypothesis that Flow may decrease intrinsic motivation in the long term, unlike previous studies. In line with adaptation level theory and the law of diminishing marginal utility, the satisfaction derived from Flow is continuously decreasing. At some point, the individual's progress is limited and they reach a point where they no longer experience FLOW. However, the individual will continue to try because the desire to experience FLOW again exists. However, failure to experience FLOW and repeated failure will lead to sadness, which will decrease intrinsic motivation.

Measurement of Flow Ripple Generated by Balanced Vane Pumps in Automotive Power Steering Systems (동력조향용 압력평형형 베인펌프의 유량맥동 계측)

  • Kim, Do-Tae;Kim, Jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.70-78
    • /
    • 2000
  • A balanced vane pump for the use of automotive power steering systems generates a flow ripple which is imposed upon the mean flow rate. The flow ripple interacts with the characteristics of the connected pipes, valves and steering gear in a complex manner to produce a pressure ripple, also known as fluid-borne noise. In order to reduce vibration level and produce quieter and more reliable power steering systems, it is important to measure the flow ripple produced by a pump with high accuracy and fast response. In this paper, the flow ripple generated by a vane pump in automotive power steering systems is measured by the remote instantaneous flow rate measurement method (RIFM) using hydraulic pipeline dynamics. In experiment, flow and pressure ripple wave forms are measured under various operating conditions. Also, the parameters affected upon the flow and pressure ripple are investigated by the frequency analysis.

  • PDF

Debris Flow Risk Evaluation and Ranking Method for Drainage Basin adjacent to Road (도로인근 유역의 토석류 위험평가 및 등급화 방안)

  • Kim, Kyung-Suk;Jang, Hyun-Ick
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.279-290
    • /
    • 2010
  • Technical countermeasures against debris flow should be established upon the risk level of the target location. Risk of debris flow should consider the hazard imposed by debris flow and vulnerability of the facilities to debris flow. In this research, we have defined the target location for risk evaluation and suggested scoring method of hazard of debris flow and vulnerability of road to debris flow. By defining risk rank into 6 categories in terms of possibility of damage during rainfall and using the risk scores of 46 debris flow cases, we have suggested risk ranking matrix. The method can be used in ranking the drainage basin adjacent to road by simply determining the hazard with vulnerability score and can be used for planning the debris flow countermeasures.

  • PDF

A Study on the Steady Flow of Intake Port in Single Cylinder Engine Head (단기통 엔진 헤드에서 흡기포트의 정상유동에 관한 연구)

  • Kim, Dae-Yeol;Choi, Soo-Kwang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.4
    • /
    • pp.13-21
    • /
    • 2007
  • This paper presents characteristics of steady flow by variation of a combustion chamber and an intake port. Gas flow field inside a combustion chamber is the important factor in improving combustion stability and reduction of emission level. The flow characteristics such as flow coefficient, tumble ratio and swirl ratio are measured by the steady flow rig test with an impulse meter in this study. In the measuring, the valve lifts are varied between 1mm to 10mm. The three combustion chambers and two intake ports were applied to the steady flow apparatus in order to investigate the effect of swirl and tumble on the in-cylinder flow. As a result, tumble ratio were found to be different by variation of the combustion chambers and the intake ports. The data from the present study can be applied to design of a similar engine as basic data.

An Experimental Study for Noise Reduction of the Cross-Flow Fan of the Room Air-Conditioners

  • Koo, Hyoung-Mo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.2
    • /
    • pp.89-100
    • /
    • 2000
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectra of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed, which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared with and without the bounding fence for various flow rates.

  • PDF

An experimental study for noise reduction of the cross-flow fan of the room air-conditioners (에어컨용 직교류홴의 저소음화를 위한 실험적 연구)

  • 구형모
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.871-879
    • /
    • 1999
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectrums of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared of the experimental rig with and without the bounding fence for various flow rates.

  • PDF

Mathematical Modelling on THM Coupling in High-Level Radioactive Waste Repository (고준위 방사성폐기물 처분장에서의 THM 상호반응의 수학적 모델 개발)

  • 황용수;김진웅;강철형
    • Tunnel and Underground Space
    • /
    • v.8 no.1
    • /
    • pp.26-36
    • /
    • 1998
  • To assess the groundwater flow near high-level radioactive waste repositories, it is important to understand the effect of coupling among thermal, hydraulic, and mechanical effects. In this paper, detailed mathematical approach to model the groundwater flow near the waste form surrounded by buffer, influenced by decay heat of radioactive waste along with stress change is developed. Two cases(1) before the full expansion of buffer and (2) after the full expansion of buffer are modelled. Based on the mathematical models in this paper, detailed numerical study shall be pursued later.

  • PDF

A Modified REDP Aggregate Marker for improving TCP Fairness of Assured Services

  • Hur Kyeong;Eom Doo-Seop;Tchah Kyun-Hyon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.1B
    • /
    • pp.86-100
    • /
    • 2004
  • To provide the end-to-end service differentiation for assured services, the random early demotion and promotion (REDP) marker in the edge router at each domain boundary monitors the aggregate flow of the incoming in-profile packets and demotes in-profile packets or promotes the previously demoted in-profile packets at the aggregate flow level according to the negotiated interdomain service level agreement (SLA). The REDP marker achieves UDP fairness in demoting and promoting packets through random and early marking decisions on packets. But, TCP fairness of the REDP marker is not obvious as for UDP sources. In this paper, to improve TCP fairness of the REDP marker, we propose a modified REDP marker where we combine a dropper, meters and a token filling rate configuration component with the REDP marker. To make packet transmission rates of TCP flows more fair, at the aggregate flow level the combined dropper drops incoming excessive in-profile packets randomly with a constant probability when the token level in the leaky bucket stays in demotion region without incoming demoted in-profile packets. Considering the case where the token level cannot stay in demotion region without the prior demotion, we propose a token filling rate configuration method using traffic meters. By using the token filling rate configuration method, the modified REDP marker newly configures a token filling rate which is less than the negotiated rate determined by interdomain SLA and larger than the current input aggregate in-profile traffic rate. Then, with the newly configured token filling rate, the token level in the modified REDP marker can stay in demotion region pertinently fir the operation of the dropper to improve TCP fairness. We experiment with the modified REDP marker using ns2 simulator fur TCP sources at the general case where the token level cannot stay in demotion region without the prior demotion at the negotiated rate set as the bottleneck link bandwidth. The simulation results demonstrate that through the combined dropper with the newly configured token filling rate, the modified REDP marker also increases both aggregate in-profile throughput and link utilization in addition to TCP fairness improvement compared to the REDP marker.

Development and Uncertainty Evaluation of New Piston (새로운 개념의 피스톤 푸루버 개발 및 불확도 평가)

  • Choi, Hae Man;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.354-359
    • /
    • 2002
  • The new piston prover was developed and the flow measurement uncertainty of this piston prover was evaluated according to ISO/IEC 17025. The laser interferometer was employed to measure accurately the testing time. Uncertainty was calculated with evaluation of various uncertainty factors affected in flow measurement. The expanded uncertainty(U) of the piston Over was $1.3{\times}10^{-3}$ (at the confidence level of $95\%$). This evaluation example will be useful in flow measurement uncertainty determination of other gas flow measurement system.

  • PDF