Flow Condensation Heat Transfer Coefficients of Pure Refrigerants (순수냉매의 흐름응축 열전달계수)

  • 김신종;송길홍;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.175-183
    • /
    • 2002
  • Flow Condensation heat transfer coefficients (HTCs) of Rl2, R22, R32, Rl23, Rl25, R134a, R142b were measured experimentally on a horizontal plain tube. The experi- mental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water-glycol loop. The test section in a refrigerant loop was made of a copper tube of 8.8 mm inner diameter and 1000 mm length respectively. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. All tests were performed at a filed refrigerant saturation temperature of 4$0^{\circ}C$ with mass fluxes of 100, 200, 300 kg/$m^2$s. The experimental result showed that flow condensation HTCs increase as the quality, mass flux, and latent heat of condensation increase. At the same mass flux, the HTCs of R32 and R142b were higher than those of R22 by 35~45% and 7~14% respectively while HTCs of R134a and Rl23 were similar to those of R22. On the other hand, HTCs of Rl25 and Rl2 were lower than those of R22 by 28 ~30% and 15 ~25% respectively Finally, a new correlation for flow condensation HTCs was developed by modifying Dobson and Chato's correlation with the latent heat of condensation considered. The correlaton showed an average deviation of 13.1% for all pure fluids data indicating an excellent agreement.

Study on the two-dimensional Formation Control of Free Surface of Magnetic Fluid by Electromagnetic Force (전자기력에 의한 자성유체의 2차원 자유표면 형상 제어에 관한 연구)

  • 안창호;지병걸;이은준;박명관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.979-982
    • /
    • 2003
  • In this study, because of change in electromagnetic force, deformation of the free surface motion of a magnetic fluid is changed. Deformation of the free surface motion of a magnetic fluid for the change in electromagnetic force is discussed and carried out theoretically and experimentally on the basis of Rosensweig Ferrohydrodynamic Bernoulli Equation. Objective of this study explicates free surface motion by electromagnetic force and planes to designed controller. To control free surface of magnetic fluid, it embody designed two-dimensional free surface form of magnetic fluid. By using this characteristics, they applied to oscillator for surface control, flow control, boundary layer control. Strength of magnetic field and height of free surface of magnetic fluid measure as a hall-effect sensor. As performing height control of magnetic fluid, the result will be presented possibility of free surface deformation control.

  • PDF

An Analysis of Patterns of Knowledge Flows of Science and Technology Using Scientific Papers and Patents (과학논문과 특허를 통한 과학기술 지식흐름의 특성분석)

  • Park, Hyun-Woo;Sung, Oong-Hyun
    • Knowledge Management Research
    • /
    • v.9 no.1
    • /
    • pp.39-59
    • /
    • 2008
  • This paper is an empirical study to analyze the flow of knowledge in science and technology in order to predict technology innovation. Here, we use the information of scientific papers and patents to look into the characteristics of how knowledge is created in science, technology and industry. Based on the characteristics we find, we are able to understand the relationships between science and technology, and technology and industry. In this paper, we adopt multivariate analysis of variance (MANOVA) using scientific papers in SCI database and US patents filed by Korean inventors in order to analyze the patterns of knowledge flows of science and technology. Finally, we present the direction for future study by using the research results.

  • PDF

Diagnosis on performance of turbine flowmeter using differential pressure in the meter (차압을 이용한 터빈유량계 성능 진단)

  • Ha, Young-cheol;Her, Jae-young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.153-159
    • /
    • 2004
  • We have investigated the feasibility of using differential pressure(pressure drop) of gas turbine meter to diagnose turbine performance degradation caused by mechanical wearing damage and/or dirt buildup or erosion. If the differential pressure between the upstream piping and the throat of a turine meter can be correlated to meter flow rate over the operating range of the meter, then a relatively simple differential pressure measurement in the filed might be used to detect meter performance changes. To test this method, we have conducted two experimental simulation on Straightener Integrated Type(SIT) turbine meter. One is fur dirt buildup on turbine blade, the other is for eccentricity of the blade. Results show that this method provide a reliable measure of performance degradation and is useful maintenance indicator.

  • PDF

Validation of Assessment for Mean Flow Field Using Spatial Averaging of Instantaneous ADCP Velocity Measurements (ADCP 자료의 공간평균을 이용한 평균유속장 산정에 대한 검증)

  • Kim, Dong-Su;Kang, Boo-Sik
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.107-118
    • /
    • 2011
  • While the assessment of mean flow field is very important to characterize the hydrodynamic aspect of the flow regime in river, the conventional methodologies have required very time-consuming efforts and cost to obtain the mean flow field. The paper provides an efficient technique to quickly assess mean flow field by developing and applying spatial averaging method utilizing repeatedly surveyed acoustic Doppler current profiler(ADCP)'s cross-sectional measurements. ADCP has been widely used in measuring the detailed velocity and discharge in the last two decades. In order to validate the proposed spatial averaging method, the averaged velocity filed using the spatial averaging was compared with the bench-mark data computed by the time-averaging of the consistent fix-point ADCP measurement, which has been known as a valid but a bit inefficient way to obtain mean velocity field. The comparison showed a good agreement between two methods, which indicates that the spatial averaging method is able to be used as a surrogate way to assess the mean flow field. Bed shear stress distribution, which is a derived hydrodynamic quantity from the mean velocity field, was additionally computed by using both spatial and time-averaging methods, and they were compared each other so as to validate the spatial averaging method. This comparison also gave a good agreement. Therefore, such comparisons proved the validity of the spatial averaging to quickly assess mean flow field. The mean velocity field and its derived riverine quantities can be actively used for characterizing the flow dynamics as well as potentially applicable for validating numerical simulations.

DESIGN OF ANNULAR REVERSIBLE COMBUSTOR WITH 3 DIMENSIONAL CFD ANALYSIS (3차원 CFD해석을 이용한 환형 역류형 연소기설계)

  • Na, S.K.;Shim, J.K.;Park, H.H.;Lee, S.J.;Chen, S.B.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.247-251
    • /
    • 2010
  • It is very difficult to understand and estimate the heat transfer and flow characteristics in the combustor, which is one of main components in the Auxiliary Power Unit (APU), because its flow filed has very complex structure. In this paper, specified is characteristics of injection and flow through different air goles in the liner, which consist of large circular holes film cooling holes, and tangential air swirl holes. The durability of the liner depends on whether the surface of the liner is exposed to the hot gas over 1000 $^{\circ}C$ of a temperature or net. It is proved that the locations of hot spots estimated from the calculation using CFD are matched well with that from the test. In this study, CFD simulations were performed to examine the heat transfer and temperature distributions in and about a liner wall with film cooling on the wall. This computational study is based on the ensemble average continuity, compressible Navier-Stokes, energy, and PDF combustion equations closed by the standard $k-{\varepsilon}$ turbulence model with standard wall functions for the gas phase and the Fourier equations for conduction in the solid phase.

  • PDF

Mode analysis and low-order dynamic modelling of the three-dimensional turbulent flow filed around a building

  • Lei Zhou;Bingchao Zhang;K.T. Tseb
    • Wind and Structures
    • /
    • v.38 no.5
    • /
    • pp.381-398
    • /
    • 2024
  • This study presents a mode analysis of 3D turbulent velocity data around a square-section building model to identify the dynamic system for Kármán-type vortex shedding. Proper orthogonal decomposition (POD) was first performed to extract the significant 3D modes. Magnitude-squared coherence was then applied to detect the phase consistency between the modes, which were roughly divided into three groups. Group 1 (modes 1-4) depicted the main vortex shedding on the wake of the building, with mode 2 being controlled by the inflow fluctuation. Group 2 exhibited complex wake vortexes and single-sided vortex phenomena, while Group 3 exhibited more complicated phenomena, including flow separation. Subsequently, a third-order polynomial regression model was used to fit the dynamics system of modes 1, 3, and 4, which revealed average trend of the state trajectory. The two limit cycles of the regression model depicted the two rotation directions of Kármán-type vortex. Furthermore, two characteristic periods were identified from the trajectory generated by the regression model, which indicates fast and slow motions of the wake vortex. This study provides valuable insights into 3D mode morphology and dynamics of Kármán-type vortex shedding that helps to improve design and efficiency of structures in turbulent flow.

CFD Analysis of Axial Flow Cyclone Separator for Subway Station HVAC System (지하역사 공기조화기에 적용 가능한 미세먼지 제거용 사이클론의 수치해석적 연구)

  • Kim, Jin-Kwan;Kim, Ho-Joong;Lee, Myung-Jun;Kim, Tae-Sung;Kwon, Soon-Bark
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.546-550
    • /
    • 2008
  • In this study, 3-dimensional Computational Fluid Dynamics (CFD) analysis was induced to simulate air flow and particle motion in the axial flow cyclone separator. The commercialized CFD code FLUENT was used to visualize pressure drop and particle collection efficiency inside the cyclone. We simulated 4 cyclone models with different shape of vane, such as turning angle or shape of cross section. For the air flow simulation, we calculated the flow field using standard ${\kappa}-{\varepsilon}$ turbulence viscous model. Each model was simulated with different inlet or outlet boundary conditions. Our major concern for the flow filed simulation was pressure drop across the cyclone. For the particle trajectory simulation, we adopted Euler-Lagrangian approach to track particle motion from inlet to outlet of the cyclone. Particle collection efficiencies of various conditions are calculated by number based collection efficiency. The result showed that the rotation angle of the vane plays major roll to the pressure drop. But the smaller rotation angle of vane causes particle collection efficiency difference with different inlet position.

  • PDF

Analysis of Flow and Bed Change on Hydraulic Structure using CCHE2D : Focusing on Changnyong-Haman (CCHE2D를 이용한 수리구조물에 의한 흐름 및 하상변동 연구 -창녕함안보를 중심으로-)

  • Ahn, Jung Min;Lyu, Siwan
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.7
    • /
    • pp.707-717
    • /
    • 2013
  • Channel-bed of erosion and sedimentation, where eroded bed and bank materials re-deposit through the action of flow, is a natural phenomenon in alluvial systems. Analysis using a numerical model is important to understand the sediment transport mechanism associated with erosion and sedimentation near weirs and other hydraulic structures within riverine systems. The local riverbed change near a hydraulic structure (Changnyong-Haman multi-function weir in Nakdong river) has been analyzed in order to examine the effect of hydraulic structure on local bed change. A 2D numerical model (CCHE-2D) has been implemented to simulate the sedimentation and erosion over a reach (10 km) including the weir. For the calibration and verification of the model, the rainfall data from a real event (Typoon 'Maemi' in 2003) has been used for flow and stage simulation. And the simulated results show a good agreement with the observed data for whole domain. From the result, it was found that the installation and operation of weir can aggravate the local bed change caused from the flow field change and resulting redistribution of sediment.

Yield Mapping of a Small Sized Paddy Field (소구획 경지에서의 벼 수확량 지도 작성)

  • 정선옥;박원규;장영창;이동현;박우풍
    • Journal of Biosystems Engineering
    • /
    • v.24 no.2
    • /
    • pp.135-144
    • /
    • 1999
  • An yield monitoring system plays a key role in precision farming. An yield monitoring system and a DGPS were implemented to a widely used domestic combine for yield mapping of a small sized paddy field, and yield mapping algorithms were investigated in this study. The yield variation in the 0.1ha rice paddy field was measured by installing a yield flow sensor and a grain moisture sensor at the end of the clean grain elevator discharging grains into a grain tank. Yield map of the test filed was drawn in a point map and a linear interpolated map based on the result of the field test. The size of a unit yield grid in yield mapping was determined based on the combine traveling speed, effective harvesting width and data storing period. It was possible to construct the yield map of a small sized paddy field.

  • PDF