• Title/Summary/Keyword: flow contraction

Search Result 254, Processing Time 0.023 seconds

Numerical Analysis on the Internal Flow Field Characteristics of Wind Tunnel Contractions with Morel's Equation (모렐 식을 갖는 풍동수축부의 내부유동장 특성에 대한 수치해석)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.22 no.1
    • /
    • pp.11-17
    • /
    • 2018
  • The steady-state, incompressible and three-dimensional numerical analysis was carried out to evaluate the internal flow fields characteristics of wind tunnel contractions made by Morel's curve equations. The turbulence model used in this study is a realizable ${\kappa}-{\varepsilon}$ well known to be excellent for predicting the performance of the flow separation and recirculation flow as well as the boundary layer with rotation and strong back pressure gradient. As a results, when the flow passes through the interior space of the analytical models, the flow resistance at the inlet of the plenum chamber is the largest at $Z_m=300$, 400 mm, but the smallest at $Z_m=700mm$. The maximum turbulence intensity in the test section is about 2.5% when calculated by the homogeneous flow, so it is improved by about 75% compared to the 10% turbulence intensity at the inlet of the plenum chamber due to the contraction.

Study on centerline turbulent structures of circular contraction and expansion ducts (수축부와 확대부의 중심 유동에서 나타나는 대칭적 난류구조에 관한 연구)

  • Han,Yong-Un;Lee, Jang-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.2
    • /
    • pp.221-228
    • /
    • 1998
  • In order to look into the comparative flow characteristics between a circular contraction duct and a circular expansion duct the both centerline turbulent structures have been investigated by the hot wire anemometry. Both of the contraction and the expansion have Morel type contours. Means, turbulences, and triple moments have been measured for the turbulent kinetic energy budgets along their centerlines. It is resulted that mean velocities of both have much deviated from theoretical values calculated by one-dimensional continuity considerations, and that for the same upstream condition, the expansion maintains the isotropy in general while the contraction maintains a severe anisotropy through the whole duct. The mean transport of the TKE along the expansion is willing to balance mostly with the dissipation in the TKE budgets while that along the contraction is balanced with the production in the turbulent kinetic energy equation.

INFLUENCE OF IRRADIATION MODES ON THE MICROHARDNESS AND THE POLYMERIZATION CONTRACTION OF COMPOSITE RESIN POLYMERIZED WITH LED CURING UNIT (LED 광중합기의 조사 mode가 복합레진의 미세경도 및 수축응력에 미치는 영향)

  • Park, In-Ho;Oh, You-Hyang;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.312-320
    • /
    • 2005
  • The purpose of this study was to evaluate the polymerization contraction and the microhardness of compostie resin($Supreme^{(R)}$, Filtek $Flow^{(R)}$, 3M-ESPE, USA) according to irradiation modes of LED curing unit(Elipar $Freelight^{(R)}$, 3M-ESPE, USA). The strain guage method was used for determination of polymerization contraction. Sample were divided by 6 groups according to curing modes and filling method. Group A: $Supreme^{(R)}$, Filtek $Flow^{(R)}$ lining, 10seconds curing, Group B: $Supreme^{(R)}$, Filtek $Flow^{(R)}$ lining, 15seconds curing, Group C: $Supreme^{(R)}$, Filtek $Flow^{(R)}$ lining, 15seconds soft start curing, Group D: $Supreme^{(R)}$ only, 10seconds curing, Group E: $Supreme^{(R)}$ only, 15seconds curing, Group F: $Supreme^{(R)}$ only, 15seconds soft start curing. Preparations of acrylic molds were followed by filling and curing. Strain guage attached to each sample were connected to a strainmeter. Measurements were recorded at each second for the total of 10 minutes including the periods of light application. And microhardness of each group after 24hours from light irradiation were measured. Obtained data were analyzed statistically using Repeated measures ANOVA and Tukey test. The results of the present study are as follows: 1. In flowable resin liner group, soft start curing group was not found decrease of polymerization contraction. But, In Supreme only filling group, the lowest polymeriation contraction was found in soft start curing group. 2. 10 seconds curing group showed statistically significant reduction of polymerization contraction compared with 15 seconds curing group(p<0.05). 3. The microhardness values of each group not revealed significant difference(p>0.05). But, lower surface microhardness was not reached 80% of upper surface microhardness.

  • PDF

Flow Analysis of Automotive Oil Pump of Gerotor Type (자동차용 제로터형 오일 펌프의 유동 해석)

  • Won, Chan-Shik;Hur, N.;Kwon, Sung Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.4 s.21
    • /
    • pp.7-13
    • /
    • 2003
  • Flow characteristics of an automotive oil pump of gerotor type have been investigated numerically. For the simulation of a gerotor whose inner and outer rotors rotate at different speeds, node expansion and contraction method was adopted. ASI (Arbitrary Sliding Interfaces) method was also applied at interface between rotating gerotor and stationary volute. Studied are the flow rates depending on various gerotor in the gap are also studied. The present results showed good agreement with the experimental data.

Effects of Dilatation and Vortex Stretching on Turbulence in One-Dimensional and Axisymmetric Flows (일차 및 축대칭유동에서 밀도변화가 난류에 미치는 영향)

  • Kim Jin-Hwa;Yoo Jung Yul;Kang Shin-Hyoung
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.831-834
    • /
    • 2002
  • An analytic approach is attempted to predict the amplification of turbulence in compressible flows experiencing one-dimensional and axisymmetric bulk dilatation. The variations of vortex radius and vorticity are calculated, and then the amplification of turbulence is obtained from them by tracking three representative vortices. For a one-dimensionally compressed flow, the present analysis slightly underestimates the amplification of velocity fluctuations and turbulent kinetic energy, relative to that of rapid distortion theory in the solenoidal limit. For an axisymmetrically distorted flow, the amplification of velocity fluctuations and turbulent kinetic energy depend not only on the density ratio but also on the ratio of streamwise mean velocities, which represents streamwise vortex contraction/stretching. In all flows considered, the amplification of turbulence is dictated by the mean density ratio. In the axisymmetric flow, streamwise vortex stretching/contraction, however, alters the amplification slightly.

  • PDF

Effects of Interferential Current Stimulation on the Peripheral Blood Velocity in Healthy Subjects (간섭전류자극이 말초 혈류속도에 미치는 영향)

  • Park Jang-Sung;Lee Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.37-42
    • /
    • 1999
  • The purpose of this study was to determine whether percutaneous interferential current stimulation on thoracic sympathetic ganglia with amplitude modulated frequency (AMF) $90\~100$ bps and subthreshold of muscle contraction for 10 minutes on peripheral blood flow velocity in healthy subjects. Thirty-seven healthy volunteers were assigned randomly into an experimental group (n=25) and a control group (n=12). the experimental group received interferential current stimulation with subthreshold of the muscle contraction of current at AMF $90\~100$ bps on $1st\~5th$ thoracic sympathetic ganglial region for 10 minutes. The control group received same handling and electode placement, but no current was applied. Using a Doppler blood flow meter, the radial arterial blood flow velocities and the pulse raters were determined for two-way analysis of variance for repeated measures on time and group. There were no significant difference between the two groups with respect to the changes in arterial blood flow velocity and pulse rate over the four measurement times. Interferential current stimulation did not change in mean blood flow velocity and pulse rate. We conclude that interferential current stimulation on the thoracic sympathetic ganglia, as used in this study, did not dilate peripheral artery. This results suggests that interferential current stimulation dose not alter the activtiy of sympathetic nerve.

  • PDF

Numerical Study of Non-Newtonian Flow Characteristics in Sudden Contraction-Expansion Channel (급축소-확대관에서 비뉴턴유체의 유동 특성에 관한 수치적 연구)

  • Kim, Hyung Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.591-597
    • /
    • 2013
  • Because most existing non-Newtonian models are not suitable for application to the lattice Boltzmann method, theoretical and numerical studies in this regard remain challenging. In this study, the hydrokinetic (HK) model was modified and applied to a 3D sudden contraction-expansion channel flow, and the characteristics of the HK model flow were evaluated to generate non-trivial predictions in three-dimensional strong shear flows. The HK model is very efficient for application to the lattice Boltzmann method because it utilizes the shear rate and relaxation time. However, the simulation would be unstable in a high shear flow field because the local relaxation time sharply decreases with an increase in the shear rate in a strong shear flow field. In the HK model, it may become necessary to truncate the relaxation time and non-dimensional parameter to obtain stable numerical results.

EFFECT OF STEP CURING ON THE CONTRACTION STRESS AND MARGINAL ADAPTATION OF RESIN RESTORATION (단계별 광중합 방식이 복합레진 수복물의 수축 응력과 변연 접합도에 미치는 영향)

  • Park, Jong-Whi;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.221-232
    • /
    • 2006
  • The purpose of this study was to investigate the effect of step-curing mode on polymerization shrinkage and contraction of composite resin restoration. Class I cavities were prepared on the extracted human premolars. The cavities were ailed with Filtek $Z-250^{TM}$ (hybrid resin, 3M ESPE, USA) and Filtek $flow^{TM}$ (flowable resin, 3M ESPE, USA) and cured with one of the following irradiation modes; Halogen 40sec with continuous curing, LED 10sec with continuous curing, and LED 13sec with step-curing. Contraction stress was measured with strain gauge which was connected to TML $Datalogger^{TM}$ (TDS-102, SOKKI, Japan) and resin-dentin interfaces were observed by scanning electron microscope. The results of present study can be summarized as follows : 1. Composite resin restoration showed transient expansion just after irradiation of curing light. Contraction stress was increased rapidly at the early phase of polymerization and reduced slowly as time elapsed (P<0.05) 2. $Filtek\;flow^{TM}$ showed lower contraction stress than Filtek $Z-250^{TM}$ regardless of curing modes. 3. LED step-curing mode showed lowest contraction stress in Filtek $Z-250^{TM}$ compared with other curing modes(P<0.05). 4. LED step-curing mode showed lowest contraction stress in $Filtek\;flow^{TM}$ compared with other curing modes(P<0.05), but difference in contraction stress was not so greate as in $Filtek\;Z-250^{TM}$. 5. Polymerization of composite resin by LED light with step-curing mode and halogen light with continuous ode resulted in better marginal sealing than LED light with continuous mode.

  • PDF