• Title/Summary/Keyword: flow characteristics

Search Result 13,492, Processing Time 0.04 seconds

Characteristics of Two-Phase Flow in Vertical Pipe (수직관에서의 이상유동 특성)

  • Bae, B.M.;Sim, W.G.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.879-882
    • /
    • 2004
  • Two-phase flow exists in many industrial components. Characteristics of two-phase flow have been studied by many researchers; however, a further study of the two-phase is required for flow-induced vibration. Characteristics of two-phase flow were measured by force sensor at the end of a vertical pipe. The predominant frequency of fluctuation was obtained for various speeds of flow pattern. A correlation to slug frequency for horizontal flow was obtained by Heywood & Richardson (1979), while Legius et al (1997) for vertical flow. A coefficient based on the correlation is estimated and then compared to the existing ones. The existing empirical formulations for average void fraction were proposed by Wallis (1969), Zuber et al (1967) and Ishii (1970). In the present result, flow parameters, such as flow quality and real velocity, are evaluated with void fraction.

  • PDF

Analysis of Thermal Flow Characteristics according to the Opening Ratio of High-Pressure Valve for Hydrogen Storage Tank (수소 저장 탱크용 고압 밸브의 개도율에 따른 열·유동 특성 분석)

  • JUNG, DA WOON;CHOI, JIN;SUH, HYUN KYU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.5
    • /
    • pp.525-533
    • /
    • 2022
  • In this study, in order to numerically analyze the heat flow characteristics in the valve according to the opening rate for the solenoid valve for hydrogen supply applied to the hydrogen storage tank, flow characteristics were comparatively analyzed. Through the analysis of pressure and temperature distributions within the valve according to the high-pressure supply condition of 70 MPa or more, the heat flow characteristics in the valve, inlet and outlet passage according to the opening rate of the valve were identified. As a result a sudden change in the fluid behavior appears in the neck region of the valve, and it is understood that the flow separation caused by the flow path shape of the expanded tube has a dominant influence on the flow characteristics. And, it was confirmed that the shape of the valve seat is a factor significantly affecting the improvement of flow rate and differential pressure performance.

A Study on Flow Rate Characteristics of a Triangular Separate Bar Differential Pressure Flow Meter according to the Variation of Gas Flow Temperature (유동 가스 온도 변화에 따른 삼각 분리 막대형 차압 유량계 유량 특성에 관한 연구)

  • Kim, Kwang-Il;Yoo, Won-Yuel;Lee, Choong-Hoon
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.89-94
    • /
    • 2008
  • Differential pressure flow meters which have a shape of triangular separate bar(TSB) were tested for investigating the flow rate characteristics of the flow meters with varying the temperature of the gas flow. Three kinds of the triangular separate bar flow meters whose aerodynamic angles are different one another are used. The mass flow rate of the flow meters are evaluated using a non-dimensional parameter which includes the gas temperature, exhaust gas pressure and differential pressure at the flow meters, and atmospheric pressure. A burner system which is similar to gas turbine was used for raising the gas flow temperature. The burner system was operated with varying the air/fuel ratio by controlling both the fuel injection rate from the fuel nozzle and air flow rate from a blower. An empirical correlation between the mass flow rate at the TSB flow meter and the non-dimensional parameter was obtained. The empirical correlation showed linear relationship between the mass flow rate and the non-dimensional parameter H. Also, the mass flow rate characteristics at the TSB flow meter was affected by the gas temperature.

An Empirical Study on the Flow Experience Affected by Characteristics of Mobile Internet (모바일 인터넷 특성이 플로우 경험에 미치는 영향에 관한 연구)

  • Yoo, Sang-Jin;Choi, Eun-Bin;Kim, Hyo-Jung
    • Information Systems Review
    • /
    • v.8 no.1
    • /
    • pp.125-139
    • /
    • 2006
  • Recently, as mobile internet users grow rapidly, mobile internet companies are experiencing a fierce competition to capture new customers. Under this business environment, they try to identify factors that make people use mobile internet in order to satisfy customers by providing better and diversified services. There has been enormous effort to analyze customers' behavior in choose and use mobile internet services. However, there is no one best methodology to identify factors to attract customers yet. Thus, the study applied the flow construct proposed by Csikszentmihalyi(1977) and expanded by Hoffman and Novak(1996) to identify environmental factors of internet which has impact on users' mobile internet usage. To implement the study, the following activities have been done: literature reviews on service acceptance model and flow structure, questionnaire survey, suggestion of the flow model on mobile internet, and hypothesis test. For the study, 242 out of 307 samples collected were statistically analyzed using SPSS 10.0, AMOS 4.0 statistics package. The findings of this study are as follows: First, mobile internet environment factors influencing on challenge of flow antecedent were media characteristics(use of convenience, transmission quality), contents characteristics(uniqueness, timeliness, simplicity). Second, mobile internet environment factors influencing on skill of flow antecedent were contents(uniqueness, timeliness, simplicity), charge(definiteness and diversity of charge), usage(security, instant connectivity). Third, challenge of flow antecedent had a significant effect on flow of mobile internet usage. But it was not statistically significant that skill has an influence on flow. This study discovered the relationship between mobile internet environment factors(media characteristics, contents characteristics, charge characteristics, usage characteristics) and flow experience of mobile internet users which would be a valuable insight for marketing strategies. Results shows that challenge of flow antecedent have a significant impact on flow experience in mobile internet environment. Additional, media characteristics, contents characteristics of mobile internet environment factors is positively correlated with challenge of flow antecedent. In other words, mobile internet companies should provide customers with diverse service and take a challenging attitude to get customers show aggressive attitude in mobile internet usage.

Analysis of Flow Characteristics and Experiment of Conductive Liquid Metal Coupling Lorentz Force with Fluid Equation (전자력과 유동방정식을 결합한 전도성 용융금속의 유동특성 해석 및 실험)

  • Jeon, Mun-Ho;Lee, Suk-Won;Kim, Chang-Eob
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1329-1335
    • /
    • 2009
  • This paper presents the flow characteristics in the fluid circulation loop using the tubular type linear induction motor(TLIM) electromagnetic pump. A TLIM pump was designed using the equivalent and genetic algorithm for the flow system of 40[1/min]. The flow characteristics are analyzed by coupling the Maxwell equations with the Navier-Stokes equation. The analysis algorithm also takes account of the effects of the thrust. The flow characteristics are analysed with the proposed method and compared with the commercial program and experiment and discussed.

Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(2) - Comparison of ISM and PIV Measurement (정상유동 장치에서 유동 특성 평가 방법에 대한 연구(2) - ISM와 PIV 측정의 비교)

  • Park, Chanjun;Ohm, Inyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.1
    • /
    • pp.139-147
    • /
    • 2015
  • This paper is the second investigation on the evaluation methods of flow characteristics in a steady flow bench. In the previous work, several assumptions used in the steady flow bench were examined and it was concluded that the assumption of the solid rotation might cause serious problems. In this study, intake valve angle is selected as a main parameter for the assessment because the main flow direction to cylinder governed by this angle has the strongest influence on the in-cylinder flow pattern. For this purpose, four heads, which have the different angle, are prepared and the flow characteristics are estimated both by the conventional impulse swirl meter and a particle image velocimetry at 1.75 times bore position apart from the cylinder head, which is widely used plane in the steady flow measurement. The results show that both of the eccentricity and the velocity profile distort the flow characteristics when using the ISM at 1.75 plane, however, the effects of two factors act in the opposite direction. In addition, the profile's influence is much greater than that of the eccentricity.

The Factors Affecting Patient-Flow (환자흐름에의 영향요인)

  • 박재용
    • Health Policy and Management
    • /
    • v.3 no.2
    • /
    • pp.27-80
    • /
    • 1993
  • It is widely known that patients' utilization pattern for medical care facilities and the patientflow are influenced by multi-factors, such as demographic characteristics, structural characteristics of society, socio-psychological characteristics(value, attitude, norms, culture, health behavior, etc.), economic characteristics(income, medical price, relative price, physician induced demand, etc.), geographical accessibility, systematic characteristics(health care delivery system, payment methods for physician fees, form of health care security, etc.), and characteristics of medical facilities(reliability, quality of medical care, convenience, kindness, tec.). This study was conducted to research the mechanism of patient-flow according to changes of health care system(implementation of national health insurance, health care referral system and regionalization of health care utilization, etc.) and characteristics of medical facilities(ownership of hospital, characteristics of medical services, non-medical characteristics, etc.). In this study, the fact could be ascertained that the patient-flow had been influenced by changes of health care system and characteristics of medical facilities.

  • PDF

A Study on the Flow Characteristics inside a Glove Valve for Ships (선박용 글로브 밸브의 유동특성에 관한 연구)

  • Bae, Ki-Hwa;Park, Jea-Hyoun;Kang, Sang-Mo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.110-118
    • /
    • 2008
  • It is essential for the valid design of a marine flow-control valve to exactly know its flow characteristics. The present study has numerically investigated the flow characteristics inside a marine throttle-type globe valve using a kind of commercial CFD code, CFX10.0, with an adoption of the SST (Shear-Stress Transport) turbulence model. To validate the numerical approach, the flow coefficients are compared with the experimental ones. Results show that the globe valve is effective in the control of flow rate according to the opening ratio in case of the forward-direction flow, whereas it is effective in the flow shutoff in case of the reverse-direction flow. Around the inlet of the valve, a recirculation region is formed due to the blunt body shape, the turbulence intensity becomes strengthened and then an abrupt pressure loss occurs.

A FLOW CHARACTERISTICS FOR Y-CONNECTION IN HIGH-REYNOLDS-NUMBER FLOW SYSTEM (고레이놀즈수 유동 장치에서 Y형 이음의 유동 특성)

  • Park, Jung Gun;Park, Jong Ho;Park, Young Chul
    • Journal of computational fluids engineering
    • /
    • v.18 no.2
    • /
    • pp.1-8
    • /
    • 2013
  • In nuclear power plant, the reactor cooling system has maintained high-Reynolds-number flow above 1E+07 to cool a heat generated by the reactor. To minimize uncertainty for flow calibration, it is necessary to simulate the high Reynolds' number flow. Y-connection is selected to connect four (4) parallel high flow circulation pumps for maintaining the high flow rate. This paper describes the characteristics for Y-connection by computer flow simulation. It was confirmed through the results that the pressure loss of the Y-connection was lower than that of T-connection. Also as the connection angle of Y-connection was small, as the pressure loss was low.

Velocity and Shear Stress Distributions for Steady and Physiological Flows in the Abdominal Aorta/lLIAC Artery Bifurcation (복부대동맥/장골동맥 분기혈관내 정상 및 박동성 유동의 속도와 전단응력분포)

  • 서상호
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.179-186
    • /
    • 1997
  • Steady and physiological flows of a Newtonian fluid and blood in the abdominal gorta/iliac artery bifurcation are numerically simulated to understand the etiology and pathogenesis of atherosclerosis. Distributions of velocity, pressure, and wall shear stress in the bifurcated arterial vessel model are calculated to investigate the differences of flow characteristics between steady and physiological flows and to compare flow characteristics of blood with that of a Newtonian fluid For the given Reynolds number the flow characteristics of physiological flows for a Newtonian fluid and blood in the bifurcated arterial vessel are quite different from thcse of steady flows. No flow separation or flow reversal in the bifurcated region appears downstream of a stenosis during the acceleration phase. However, during the deceleration phase the flow exhibits flow separation in the outer walls of daugtlter branches, which extends to the entire wall region.

  • PDF