A Study on Flow Rate Characteristics of a Triangular Separate Bar Differential Pressure Flow Meter according to the Variation of Gas Flow Temperature  

Kim, Kwang-Il (서울산업대 자동차공학과)
Yoo, Won-Yuel ((주)이플러스티)
Lee, Choong-Hoon (서울산업대학교 자동차학과)
Publication Information
Transactions of the Korean Society of Machine Tool Engineers / v.17, no.4, 2008 , pp. 89-94 More about this Journal
Abstract
Differential pressure flow meters which have a shape of triangular separate bar(TSB) were tested for investigating the flow rate characteristics of the flow meters with varying the temperature of the gas flow. Three kinds of the triangular separate bar flow meters whose aerodynamic angles are different one another are used. The mass flow rate of the flow meters are evaluated using a non-dimensional parameter which includes the gas temperature, exhaust gas pressure and differential pressure at the flow meters, and atmospheric pressure. A burner system which is similar to gas turbine was used for raising the gas flow temperature. The burner system was operated with varying the air/fuel ratio by controlling both the fuel injection rate from the fuel nozzle and air flow rate from a blower. An empirical correlation between the mass flow rate at the TSB flow meter and the non-dimensional parameter was obtained. The empirical correlation showed linear relationship between the mass flow rate and the non-dimensional parameter H. Also, the mass flow rate characteristics at the TSB flow meter was affected by the gas temperature.
Keywords
Triangular separate bar; Differential flow meter; Gas temperature; Nondimensional parameter; Cailbration; Accuracy;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Yamagishi, Y., 2000, "The MDLT-1302T Partial Flow Dilution Tunnel for Transient Test Cycle PM Sampling," Horiba Technical Report
2 Nakamura, H., Kihara, N., Adachi, M., and Ishida, K., 2002, "Development of a Wet-Based NDIR and Its Application to On-Board Emission Measurement System," SAE Paper, No. 2002-01-0612
3 Lee, C. H., 2005, "A Study on the Automatic Measurement of Swirl Generated from Intake Port of Engine Cylinder Head Using an I-IEEE-1394 Camera and Step Motors," Transactions of the Korean Society of Machine Tool Engineers, Vol. 14, No. 6, pp. 88-94   과학기술학회마을
4 ISA 1932 (ISO-5167-3), 2003, Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular-Cross Section Conduits Running Full- Part3: Nozzles and Venturi Nozzles, International Organization for Standardization, Geneva
5 Kim, K. I., Kim, M. C., Park, D. S., and Lee, C. H., 2007, "A Study on Improvement of an Annular Bar Type D2P Flow Meter for Measuring Exhaust Flow Rate of Diesel Engine," 2007 Spring conference proceedings, Vol. 1, pp. 489-494
6 Rosemount Product Data Sheet, 1998, Diamond II-Annubaar$\circledR$ bar Primary Flow Element, Dieterich, A Subsidiary of Rosemount Inc, 00813-0100-4760 Rev. DA 11/98, USA
7 Wayne, W. S., Corrigan, E. R., Atkinson, R. J., Clark, N., and Lyons, D. W., 2001, "Measuring Diesel Emissions with a Split Exhaust Configuration," SAE paper, No. 2001-01-1949
8 Silvis, W., Williamson, J., and Kreft, N., 2003, "DVE -Direct Vehicle Exhaust Flow Measurement Using Head-type Flow meters," SAE Paper, No. 2003-01-0782
9 Rahim, R. A., Fea, P. J., and San, C. K., 2005, "Optical Tomography Sensor Configuration Using Two Orthogonal and Two rectilinear Projection Arrays," Flow Measurement and Instrumentation, Vol. 16, pp. 327-340   DOI   ScienceOn
10 Yassine, M. K., Marji, M. S., Berndt, R. W., and Laymac, T. D., 2003, "Parameters Affecting Direct Vehicle Exhaust Flow Measurement," SAE Paper, No. 2003-01-781
11 Yang, W. Q. and Liu, S., 2000, "Role of Tomography in Gas/Solids Flow Measurement," Flow Measurement and Instrumentation, Vol. 11, pp. 237-244   DOI   ScienceOn
12 Beck, M. and Hinterhofer, K., 1998, "Direct High Dynamic Flow Measurement in the Exhaust of Combustion Engines PEUS-Systems," SAE paper, No. 9808801
13 Yamagishi, Y. and Ohtsuki, S., 2000, "Tunnel Vision - A Particulate Matter Sampling System Using a Partial Flow Dilution Method Designed to Perform Sampling during a Transient Test Cycle," Testing Technology International, pp 95-99
14 Lee, C. H., Kim, K. I., Kim, M. C., and Park, D. S., 2007, "A Study on Flow Characteristics of a Separate Triangular Bar Differential Pressure Flow Meter for Measuring Exhaust Flow Rate of Diesel Engine," Journal of the Korean Society for Railway, Vol. 9, No. 6, pp. 563-568   과학기술학회마을
15 Hardy, J. E., McKnight, T. E., and Hylton, J. O., and Joy, R. D., 1999, "Real-Time Measurement of Vehicle Exhaust Gas Flow," 4th International Symposium on Fluid Flow Measurement, Report Number ORNL/CP- 102550 Denver, Colorado