• 제목/요약/키워드: flow cell

검색결과 3,119건 처리시간 0.028초

균일한 전단응력에 의한 혈관내피세포의 운동성 변화 (EFFECTS OF UNIFORM SHEAR STRESS ON THE MIGRATION OF VASCULAR ENDOTHELIAL CELL)

  • 신현정;송석현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1404-1408
    • /
    • 2008
  • The migration and proliferation of vascular endothelial cells (VEC), which play an important role in vascular remodeling, are known to be regulated by hemodynamic forces in the blood vessels. When shear stresses of 2, 6, 15 dynes/$cm^2$ are applied on mouse micro-VEC in vitro, cells surprisingly migrate against the flow direction at all conditions. While higher flow rate imposes more resistance against the cells, reducing their migration speed, the horizontal component of the velocity parallel to the flow increases with the flow rate, indicating the higher alignment of cells in the direction parallel to the flow at a higher shear stress. In addition, cells exhibit substrate stiffness and calcium dependent migration behavior, which can be explained by polarized remodeling in the mechanosensitive pathway under shear stress.

  • PDF

ATM 기반 개인 휴대 통신망에서의 핸드오프를 위한 흐름 제어 방안 (A flow control scheme for handoff on ATM-based PCN)

  • 심재정;강경훈;장경훈;김덕진
    • 전자공학회논문지S
    • /
    • 제34S권10호
    • /
    • pp.9-25
    • /
    • 1997
  • Personal Communication Networks will be composed of ATM-based broadband ISDN in the future. However, unlike the wired networks, many challenges will arise in the wireless communication service such as PCS. These callenges are frequency alteration of cell routing path, relatively very high error rate at transmission over the wireless interface, etc. Particularly, the alteration of cell routing path caused by handoff makes temporary deterioration of QoS. In this paper, the signaling flows of handoff scenarios which may occur on Personal Communication Networks are presented, and verified by Pertri-Net toolkit. In addition, the cell flow control scheme which minimizes the lagging gap between cells and maintains the cell sequence during handoff is proposed. The proposed scheme can be summarized as the differentiation of normal queue and handoff queue, and the cell flow control between these queues. For verification of the proposed scheme, we used two approaches, which are mathermatical manipulation and SLAM simulation.

  • PDF

고체산화물 연료전지의 유동방향에 따른 온도 균일성 영향 (Effect of Flow Direction on Temperature Uniformity in Solid Oxide Fuel Cell)

  • 전동협;신동열;유광현;송락현
    • 대한기계학회논문집B
    • /
    • 제41권10호
    • /
    • pp.667-673
    • /
    • 2017
  • 공개소스 전산유체 해석 라이브러리인 OpenFOAM을 이용하여 음극 지지체형 고체산화물 연료전지의 온도균일성에 관한 연구를 수행하였다. 3가지 유형의 유동흐름(병행류, 대향류, 직교류)에 대하여 수치해석이 이루어졌다. 다공성 물질내에서의 기체의 흐름은 유효확산계수를 이용하여 계산하였고 분리판의 리브 영향도 고려하였다. 전기화학반응의 계산을 위하여 실험식으로부터 얻은 집중내부저항 모델이 사용되었다. 수치해석 결과 대향류가 가장 균일한 온도분포를 나타내었다.

저 맥동 연동 펌프 기반 플로우 스루 셀 방식 용출 장치 설계 (Design of Dissolution Apparatus for the Flow-through Cell Method Based on the Low Pulsation Peristaltic Pump)

  • 조준성;정석;박상범
    • 한국기계가공학회지
    • /
    • 제19권1호
    • /
    • pp.11-18
    • /
    • 2020
  • The emergence of the flow-through cell (FTC) method has made up for the limitations of previous dissolution test methods, but the high cost of the FTC dissolution devices have seriously hindered the progression of research and application of the FTC. This new design uses a peristaltic pump to simulate the sinusoidal flow rate of a piston pump. The flow profile of each peristaltic pump was sinusoidal with a pulsation of 120 ± 1 pulses per minute, and the flow rate ranged from 1.0 - 36.0 mL/min. The flow control of each channel was adjusted independently so the flow errors of the seven channels were close to 2%. The structure of the system was simplified, and the cost was reduced through manual sampling and immersing the FTC in a water bath. The dissolution rate of the theophylline and aminophylline films was determined, and good experimental results were obtained.

연료전지용 캐소드 공기블로어의 비정상 내부유동장 연구 (Unsteady Internal Flow Analysis of a Cathode Air Blower Used for Fuel Cell System)

  • 장춘만;이종성
    • 신재생에너지
    • /
    • 제8권3호
    • /
    • pp.6-13
    • /
    • 2012
  • This paper describes unsteady internal flow characteristics of a cathode air blower, used for the 1 kW fuel cell system. The cathode air blower considered in the present study is a diaphragm type blower. To analyze the flow field inside the diaphragm cavity, compressible unsteady numerical simulation is performed. Moving mesh system is applied to the numerical analysis for describing the volume change of the diaphragm cavity in time. Throughout a numerical simulation by modeling the inlet and outlet valves in a diaphragm cavity, unsteady nature of an internal flow is successfully analyzed. Variations of mass flow rate, force and pressure on the lower moving plate of a diaphragm cavity are evaluated in time. The computed mass flow rate at the same pressure and rotating frequency of a motor has a maximum of 5 percent error with the experimental data. It is found that flow pattern at the suction process is more complex compared to that at the discharge process. Unsteady nature of internal flow in the cathode air blower is analyzed in detail.

검사체적 방법을 이용한 평직의 투과율 계수 예측 (Permeability prediction of plain woven fabric by using control volume finite element method)

  • Y. S. Song;J. R. Youn
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.181-183
    • /
    • 2002
  • The accurate permeability for preform is critical to model and design the impregnation of fluid resin in the composite manufacturing process. In this study, the in-plane and transverse permeability for a woven fabric are predicted numerically through the coupled flow model which combines microscopic with macroscopic flow. The microscopic and macroscopic flow which are flows within the micro-unit and macro-unit cell, respectively, are calculated by using 3-D CVFEM(control volume finite element method). To avoid checker-board pressure field and improve the efficiency on numerical computation, A new interpolation function for velocity is proposed on the basis of analytic solutions. The permeability of plain woven fabric is measured through unidirectional flow experiment and compared with the permeability calculated numerically. Based on the good agreement of the results, the relationships between the permeability and the structures of preform such as the fiber volume fraction and stacking effect can be understood. The reverse and the simple stacking are taken in account. Unlike past literatures, this study is based on more realistic unit cell and the improved prediction of permeability can be achieved. It is observed that in-plane flow is more dominant than transverse flow in the real flow through preform and the stacking effect of multi-layered preform is negligible. Consequently, the proposed coupled flow model can be applied to modeling of real composite materials processing.

  • PDF

유세포분석기를 이용한 정상치수조직과 염증성 치수조직 내의 임파구 분포에 관한 연구 (FLOW CYTOMETRIC ANALYSIS OF LYMPHOCYTES IN NORMAL AND INFLAMED PULP)

  • 김선아;배광식;임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.374-387
    • /
    • 1997
  • The purpose of this study was to examine the distribution of lymphocyte populations in normal, reversibly inflamed and irreversibly inflamed human dental pulp tissues using flow cytometry. Flow cytometry, with specific antibody and fluorochrome reagent allows us to know cellular properties of hematolymphoid cells by measuring fluorescence of stained cells. Before extirpation of pulps in routine endodontic treatment, the clinical diagnosis were performed by symptom. The extirpated pulp tissues were divided into normal pulp group (N=5), reversible pulpit is group(N=10) and irreversible pulpitis group(N=7). The specimen was placed into RPMI 1640 medium, minced into small pieces, and then digested in medium with collagenase. The cell suspension was resuspended in PBS for monoclonal antibody staining of T lymhocytes(CD3+), B lymphocytes (CD19+), T helper cell (CD4+) and T supressor cell (CD8+). The percentages of cells were counted by FACStar(BD) flow cytometer. Following results were obtained; 1. In the most normal and inflamed pulps, the percentages of T lymphocyte, B lymphocytes, T helper cell and T suppressor/cytotoxic cell were less than 1 % in total counted pulpal cells. 2. The higher percentages of T, B, T helper and T suppressor cells were observed in irreversible pulpitis group as compared with the normal pulp and reversible pulpitis group but the differences between groups were not statistically significant (p>0.05). 3. The percentages of T helper cells (CD4 + cells) were greater than that of T suppressor/cytotoxic cells (CD8 + cells) in the inflamed pulps.

  • PDF

Separation of Human Breast Cancer and Epithelial Cells by Adhesion Difference in a Microfluidic Channel

  • Kwon, Keon-Woo;Choi, Sung-Sik;Kim, Byung-Kyu;Lee, Se-Na;Lee, Sang-Ho;Park, Min-Cheol;Kim, Pil-Nam;Park, Suk-Ho;Kim, Young-Ho;Park, Jun-Gyul;Suh, Kahp-Y.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권3호
    • /
    • pp.140-150
    • /
    • 2007
  • A simple, label-free microfluidic cell purification method is presented for separation of cancer cells by exploiting difference in cell adhesion. To maximize the adhesion difference, three types of polymeric nanostructures (50nm pillars, 50nm perpendicular and 50nm parallel lines with respect to the direction of flow) were fabricated using UV-assisted capillary moulding and included inside a polydimethylsiloxane (PDMS) microfluidic channel bonded onto glass substrate. The adhesion force of human breast epithelial cells (MCF10A) and human breast carcinoma (MCF7) was measured independently by injecting each cell line into the microfluidic device followed by culture for a period of time (e.g., one, two, and three hours). Then, the cells bound to the floor of a microfluidic channel were detached by increasing the flow rate of medium in a stepwise fashion. It was found that the adhesion force of MCF10A was always higher than that of MCF cells regardless of culture time and surface nanotopography at all flow rates, resulting in a label-free detection and separation of cancer cells. For the cell types used in our study, the optimum separation was found for 2 hours culture on 50nm parallel line pattern followed by flow-induced detachment at a flow rate of $300{\mu}l/min$.

ATM망의 히스테리시스 특성을 이용한 흐름제어기법 (Flow Control with Hysteresis effect in ATM Network)

  • 정상국;진용옥
    • 전자공학회논문지A
    • /
    • 제31A권9호
    • /
    • pp.10-17
    • /
    • 1994
  • In this paper, a priority schedling and a flow control algorithm with hysteresis effect are proposed for high-speed networks. A mathematical model for the flow control is proposed and a cell transition probability from this model is found. And the performance of the proposed algorithm is analyzed by a computer simulation. According to the simulation results, it can be shown that the priority scheduling and the flow control with hysteresis effect get the cell loss probability 0.061 better and the average delay 100ms better and the average delay 100ms beter than those of single threshold.

  • PDF

Apoptosis Induction in Human Leukemic Promyelocytic HL-60 and Monocytic U937 Cell Lines by Goniothalamin

  • Petsophonsakul, Ploingarm;Pompimon, Wilart;Banjerdpongchai, Ratana
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권5호
    • /
    • pp.2885-2889
    • /
    • 2013
  • Goniothalamin is an active compound extracted from Goniothalamus griffithii, a local plant found in northern Thailand. Goniothalamin inhibits cancer cell growth but is also toxic to normal cells. The aims of this study were to identify the cytotoxic effect of goniothalamin and the mechanism of cell death in human HL-60 and U937 cells. Cytotoxicity was determined by MTT assay and cell cycle profiles were demonstrated by staining with propidium iodide (PI) and flow cytometry. Apoptosis was confirmed by staining with annexin V-FITC/propidium iodide (PI) and flow cytometry. Reduction of mitochondrial transmembrane potential was determined by staining with dihexyloxacarbocyanine iodide and flow cytometry and expression of Smac, caspase-8 and -9 was demonstrated by Western blotting. Goniothalamin inhibited growth of HL-60 and U937 cell lines. An increase of SubG1 phase was found in their cell cycle profiles, indicating apoptosis as the mode of cell death. Apoptosis was confirmed by the flip-flop of phosphatidylserine using annexin V-FITC/PI assay in HL60 and U937 cells in a dose response manner. Furthermore, reduction of mitochondrial transmembrane potential was found in both cell types while expression of caspase-8, -9 and Smac/Diablo was increased in HL-60 cells. Taken together, our results indicate that goniothalamin-treated human leukemic cells undergo apoptosis via intrinsic and extrinsic pathways.