• 제목/요약/키워드: flow

검색결과 54,573건 처리시간 0.058초

FLUENT 5.4 코드를 이용한 양방향 유동 튜브에 대한 유동해석 (Flow Analyses using FLUENT 5.4 Code for the Bi-directional Flow Tube)

  • 강경호;윤병조;백원필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.934-938
    • /
    • 2003
  • Flow analyses using FLUENT 5.4 code were performed to validate the application of the local bidirectional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the bi-directional flow tube which can be applied for the various experimental conditions. 2-dimensional axisymmetric steady state flow analyses have been performed. By calculating the differential pressure at both the front and the rear hole of the flow tube, K values were evaluated. The K values show good linearity regardless of the tube sizes and the Re numbers in both water and air flow. And system pressure and water subcooling didn’'t affect the K values. Under the elevated pressure of 80bar with 80K water subcooling, the K value indicates a similar trend with the case of 2bar with 80K water subcooling.

  • PDF

스로틀 개폐에 따른 가솔린 엔진의 비정상상태 유량변화 특성 (Characteristics of the Air Flow Variation by Throttle Step Change in a Gasoline Engine)

  • 박경석;고상근;노승탁;이종화
    • 한국자동차공학회논문집
    • /
    • 제4권3호
    • /
    • pp.92-101
    • /
    • 1996
  • In a gasoline engine, the characteristics of air flow is very important not only for the design of the intake system geometry bout also for the accurate measurement of the induction air mass. In this study, an air flow rate measurement of the induction air mass. In this study, an air flow rate measurement was conducted by using the hot wire flow meter at the upstream of the intake port and the throttle. At the upstream of the throttle, the overshoot phenomena of the air flow rate by fast throttle opening were analyzed with choked flow. At the upstream of the intake port, the cylinder variation of the air flow rate and the difference between fast throttle opening and closing were showed during the unsteady state by the throttle step change. The results of this study can be used for the design of the throttle valve geometry and cylinder by cylinder control.

  • PDF

3차원 캐버티 표면의 스톡스 유동 가시화 및 수치해석을 통한 표면 특성 연구 (Study on the Fluid-Surface Characteristics by Using Flow Visualization and Numerical Simulation of Stokes Flow in a Cavity)

  • 허효원;이헌덕;정원혁;조동식;서용권
    • 한국가시화정보학회지
    • /
    • 제9권3호
    • /
    • pp.44-50
    • /
    • 2011
  • In this study, we propose a method for characterizing fluid-mechanical properties of a fluid surface, such as surface dilatational and shear viscosity, by matching the flow visualization and the numerical simulation for a Stokes flow in a three-dimensional cavity. The surface flow is driven by shear stress exerted on the free surface by an external gas flow. The external gas flow is simulated by using a commercial code, while the Stokes flow is calculated by an in-house code. We have found that the surface flow is very sensitive to the surface tension and other properties. The qualitative feature of the surface flow can be reproduced by the parameter tuning.

수평 응축관내 2상유동양식의 판별에 관한 연구 (Identification of Two-phase Flow Patterns in a Horizontal Tubular Condenser)

  • 이상천;한용운;신현승;이형돈
    • 설비공학논문집
    • /
    • 제5권1호
    • /
    • pp.65-72
    • /
    • 1993
  • An experiment has been carried out to identify flow patterns in a horizontal condensing flow with R-113. Characteristics of flow patterns were determined based upon a statistical analysis of differential pressure fluctuations at an orifice. The probability density function and power spectral density function of instantaneous pressure drop curves for various flow conditions were obtained. In comparison to the results of air-water flows, the flow patterns in a condensing flow such as annular, wavy, slug and plug could be identified. The experimental data determined by this technique were compared with the flow pattern maps suggested by other investigators. The result indicates that the statistical characteristics of differential pressure fluctuations at an orifice may be a useful tool for identifying flow patterns both in condensing flows and in adiabatic two-phase flows.

  • PDF

Reactive Reserve based Contingency Constrained Optimal Power Flow to Enhance Interface Flow Limits in Terms of Voltage Stability

  • Hwachang Song;Lee, Byongjun
    • KIEE International Transactions on Power Engineering
    • /
    • 제11권X00호
    • /
    • pp.27-32
    • /
    • 2001
  • This paper presents a concept of reactive reserve based contingency constrained optimal power flow (RCCOPF). RCCOPF for enhancement of interface flow limit is composed of two modules, which are the modified continuation power flow (MCPF) and reactive optimal power flow (ROPF). In RCCOPF, two modules are repeatedly performed to increase interface flow margins of selected contingent states until satisfying the required enhancement of interface flow limit. In numerical simulation, a simple example with New England 39-bus test system is shown.

수치모형을 이용한 다원주 주위의 유동 해석 (Analysis of Flow Around Multi-Circular Cylinders Using a Numerical Model)

  • 이상화;박정호
    • 한국해양공학회지
    • /
    • 제20권2호
    • /
    • pp.29-35
    • /
    • 2006
  • The flow patterns around multi-circular cylinders are studies, in order to obtain a global view on the structure of wave control and circulation of sea flow in coastal region. The flow force depends upon the vortex shedding exerted on the structure, especially how the vortex shedding affects the erosion when the structure sets on the sand bottom. Therefore, it is necessary that the flow pattern be hocked. In order to simulate the flow around multi-circular cylinders, the CFX and FLUENT of the computational fluid dynamics (CFD) program were used and compared with the experimental results of the flow visualization installation. The phenomena of flow around the multi-cylinders will be applied to fundamental data for predicting the flow force acting against the structure, erosion and sedimentation around cylinders in arrangement.

평행류 열교환기의 열.유동 해석 및 최적화 (Thermal and flow analysis for the optimization of a parallel flow heat exchanger)

  • 이관수;정지완;유재흥
    • 대한기계학회논문집B
    • /
    • 제22권2호
    • /
    • pp.229-239
    • /
    • 1998
  • The present paper examines the thermal and flow characteristics of a parallel flow heat exchanger and investigates the effects of the parameters on thermal performance by defining the flow nonuniformity. Thermal performance of a parallel flow heat exchanger is maximized by the optimization using Newton's searching method. The flow nonuniformity is chosen as an object function. The parameters such as the locations of separator, inlet, and outlet are expected to have a large influence on thermal performance of a parallel flow heat exchanger. The effect of these parameters are quantified by flow nonuniformity. The results show that the optimal locations of inlet and outlet are 19.73 mm and 10.9 mm, respectively. It is also shown that the heat transfer increases by 7.6% and the pressure drop decreases by 4.7%, compared to the reference model.

미소 유량 센서에 관한 실험적 연구 (Experimental Study on a Micro Flow Sensor)

  • 김태훈;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1783-1788
    • /
    • 2004
  • In the present paper, a micro flow sensor, which can be used at bio-delivery systems and micro heat pumps, is developed. For this, the micro flow sensor is integrated on a quartz wafer ($SiO_2$) and is manufactured by simple and convenient microfabrication processes. The micro flow sensor aims for measuring mass flow rates in the low range of about $0{\sim}20$ SCCM. The micro flow sensor is composed of temperature sensors, a heater, and a flow microchannel. The temperature sensors and the heater are manufactured by the sputtering processes in this study. In the microfabrication processes, stainless steel masks with different patterns are used to deposit alumel and chromel for temperature sensors and nichrome for the heater on the quartz wafer. The microchannel is made of Polydimethylsiloxane(PDMS) easily. A deposited quartz wafer is bonded to the PDMS microchannel by using the air plasma. Finally, we confirmed the good operation of the present micro flow sensor by measuring flow rate.

  • PDF

Particle Image Velocimetry Measurement of Unsteady Turbulent Flow around Regularly Arranged High-Rise Building Models

  • Sato, T.;Hagishima, A.;Ikegaya, N.;Tanimoto, J.
    • 국제초고층학회논문집
    • /
    • 제2권2호
    • /
    • pp.105-113
    • /
    • 2013
  • Recent studies proved turbulent flow properties in high-rise building models differ from those in low-rise building models by comparing turbulent statistics. Although it is important to understand the flow characteristics within and above high-rise building models in the study of urban environment, it is still unknown and under investigation. For this reason, we performed wind tunnel experiment using Particle Image Velocimetry (PIV) to investigate and identify the turbulent flow properties and characteristic flow patterns in high-rise building models. In particular, we focus on instantaneous flow field near the canopy and extracted flow field when homogeneous flow field were observed. As a result, six characteristic flow patterns were identified and the relationship between these flow patterns and turbulent organized structure were shown.

열전달 질량유량계 개발 (Development of Thermal Mass Flow Meter)

  • 지대성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.118-122
    • /
    • 1999
  • Thermal mass flow meter was developed using principle of convective heat transfer. The advantage of thermal mass flow meter is measuring mass flow directly, therefore, it is not required to use densitometer or temperature/pressure and DP gages. The final accuracy of this thermal mass flow meter is $\pm1.0{\%}$ or better, reproducibility is $\pm0.2{\%}$, and the response time is 600 ms. The thermal mass flow meter was developed from a single point to multi-points (maximum is 9 points), and the number of points is determined according to desired accuracy and size of piping/duct. Since this thermal mass flow meter adopted microprocessor based design, it is intrinsically accurate, self-error detectable, and has self-diagnosis function. The applications of this thermal mass flow meter are for measurement and control of HVAC air flow, other gas flow, and liquid flow.

  • PDF