• Title/Summary/Keyword: floors

Search Result 862, Processing Time 0.025 seconds

A system of multiple controllers for attenuating the dynamic response of multimode floor structures to human walking

  • Battista, Ronaldo C.;Varela, Wendell D.
    • Smart Structures and Systems
    • /
    • v.23 no.5
    • /
    • pp.467-478
    • /
    • 2019
  • Composite floor structures formed by continuous slab panels may be susceptible to excessive vibrations, even when properly designed in terms of ultimate limit state criteria. This is due to the inherent vibration characteristics of continuous floor slabs composed by precast orthotropic reinforced concrete panels supported by steel beams. These floor structures display close spaced multimode vibration frequencies and this dynamic characteristic results in a non-trivial vibration problem. Structural stiffening and/or insertion of struts between floors are the usual tentative solution applied to existing vibrating floor structures. Such structural alterations are in general expensive and unsuitable. In this paper, this vibration problem is analyzed on the basis of results obtained from experimental measurements in typical composite floors and their theoretical counterpart obtained with computational modeling simulations. A passive control system composed by multiple synchronized dynamic attenuators (MSDA) was designed and installed in these floor structures and its efficiency was evaluated both experimentally and through numerical simulations. The results obtained from experimental tests of the continuous slab panels under human walking dynamic action proved the effectiveness of this control system in reducing vibrations amplitudes.

A Comparative Study on Suicide Rates of Upper and Lower Floors of High-rise Apartment (고층아파트의 저층과 고층의 자살률 비교 연구)

  • Kim, Young-Ook;Ji, Bong-Geun;Kim, Joo-Young
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.8
    • /
    • pp.57-64
    • /
    • 2019
  • This study attempts to analyse the effects of high-rise living on suicide rates. All the apartments in the City A and every suicide were examined in detail. Research methods are as follows. First, a database including tenure type and number of residents in all apartment complexes was created. Second, apartments were categorized into two income groups of private apartments and social housing, and spatial configuration characteristics of a typical apartment were analysed. Third, differences in suicide rates were analysed for lower and upper levels in both apartment categories. Finally, the relationship between high and lower levels of apartments with their spatial configuration characteristics and suicide rates was compared. The analysis shows significant differences between lower and upper floors living residents' suicide rates. It can be stated that the low-income residents are more sensitive to living in high-rise environment. Also, it suggests the need to improve the high-rise living environment of vulnerable social groups. In addition, spatial integration decrease in upper floors of high-rise buildings, and it can be interpreted that spatial configuration may affect residents' pathological disorders or even suicidal behaviors.

The Characteristics of Traffic Noise and Its Effects on Inhabitants' Life at an Apartment Area in Taejon City (대전 신도시 일부 아파트지역 교통소음의 특성과 주민생활에 미치는 영향)

  • Park, Chan-Ho;Chang, Seong-Sil
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.94-102
    • /
    • 1999
  • To estimate the effects of environmental noise on inhabitants' life in an apartment area at Taejon, noise levels and traffic volume of major roads were measured. 203 housewives were surveyed by questionaires including general factors, noise related factors and three items of life effects: subjective evaluations on the general environment, annoyance, and life disturbance due to environmental noise. At the boundary adjacent to the road with more traffic volume, noise level was higher; according to the time, the amount of noise level was in the morning, in the evening, at noon, and at night in order. Most of boundary noise levels were higher than those of recommended standard environmental noise levels in a residential area. The boundary noise level showed a very significant linear relationship with traffic volume of near roads. Noise level difference in the apartments adjacent to three roads was ranged 2.4~6.7dB between in windows open and close state. The apartments adjacent to 9 lane or 6 lane-road, which were protected by noise prevention wall and 20m or more distance from the roads, showed higher noise level at middle floors and high floors than those of low floors; but the buildings adjacent to 4 lane-road, with no protection, showed higher noise level at low and middle floors than those of high floors. Among 203 housewives, 120(59.1%) participated in this study, and 86(73.2%) of them answered that the most serious environmental noise was traffic noise from near roads. Comparing traffic noise levels with those of before-migration, 67.0% participants found the environmental noise became louder. Fifty eight(49.5%) of the participants wanted noise protection wall and 15(25.9%) of them were willing to charge the fee. Less perception on the present noise comparing to those before-migration, less traffic volume, and lower noise levels in the apartments were related to higher scores of self-evaluation on the environment. Higher susceptibility on the present noise, areas with more traffic volume, higher boundary noise levels, and higher noise levels showed higher scores of annoyance on environmental noise and life disturbance. Considering above all things, it was suggested that traffic noise in this area was the major problem of environmental noise, and its' effect was so serious that inhabitants needed some preventive measures for better life quality.

  • PDF

The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.

A Study of the Planning Characteristics of Neowa Houses Applicable in Contemporary Housing Plans (너와집 평면특성의 현대적 차용에 관한 연구)

  • Yun, Jieheerah
    • Journal of the Korean housing association
    • /
    • v.26 no.2
    • /
    • pp.81-88
    • /
    • 2015
  • The purpose of this study was to investigate the possibility of applying the planning characteristics of Neowa houses to contemporary residential structures. Contrary to the popular assumption that traditional Korean houses have decentralized plans, local building traditions observed in Neowa houses show that the diversity among hanoks allows the incorporation of traditional spatial organization into the contemporary residences. By analyzing the spatial organization of Neowa houses, three advantageous planning characteristics were found. First, the presence of indoor wooden floors (maru or daechung) as well as outdoor wooden floors in Neowa houses is practical for Korea's weather marked by humid summers and icy winters. Secondly, the internal orientation of space in Neowa houses is more appropriate in the contemporary context of a highly urbanized society emphasizing family privacy. Thirdly, the flexibility and interchangeability of interior elements can be applied to improve efficiency. By applying the aforementioned characteristics, this study suggests ways to adopt traditional features to improve contemporary residences.

A Study on the Basement Residential Planning of Consider the Outdoor Environment (실외 환경을 고려한 지하층 주거 계획에 관한 연구)

  • Kwon Hwang-Soo;Lee Min-Sup
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2005
  • In this study aim at searching for the basement residential planning of considering outdoor spaces. It look after research results, there should be necessary for the inflow of outdoor environment factors. This basement planning is core's area expending, or installing expended dry areas and acquiring side open spaces, installing arcades, installing atrium or court yard, utilizing maisonette spaces, activating pilotis on ground floors, openning main hall, earth sheltering method, etc. These should be improvement for easy step to change basement floors easily through underground floor extend, major repair, use change of present buildings and needs to the idea through architectural design competition.

A Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses (천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 연구)

  • Ki, No-Gab;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1038-1042
    • /
    • 2007
  • The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames + Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

  • PDF

The dynamic response of a prototype steel floor using velocity-source type of excitation

  • Magalhaes, Max D.C.
    • Structural Engineering and Mechanics
    • /
    • v.46 no.3
    • /
    • pp.371-385
    • /
    • 2013
  • Vibration isolators and anti-vibration mounts are ideal, for example, in creating floating floors for gymnasiums, or performance spaces. However, it is well-known that there are great difficulties on isolating vibration transmission in structural steel components, especially steel floors. Besides, the selection of inertia blocks, which are usually used by engineers as an effective vibration control measure, is usually based on crude methods or the experience of the engineers. Thus, no simple method or indices have been available for assessing the effect of inertia blocks on vibration isolation or stability of vibratory systems. Thus, the aims of this research are to provide further background description using a FE model and present and implement a modal approach, that was validated experimentally, the latter assisting in providing improved understanding of the vibration transmission phenomenon in steel buildings excited by a velocity-source type of excitation. A better visualization of the mean-square velocity distribution in the frequency domain is presented using the concept of modal expansion. Finally, the variation of the mean-square velocity with frequency, whilst varying mass and/or stiffness of the coupled system, is presented.

Shrinkage analysis of reinforced concrete floors using shrinkage-adjusted elasticity modulus

  • Au, F.T.K.;Liu, C.H.;Lee, P.K.K.
    • Computers and Concrete
    • /
    • v.4 no.6
    • /
    • pp.437-456
    • /
    • 2007
  • The shrinkage of large reinforced concrete floors often gives rise to cracking problems. To identify the problematic areas, shrinkage movement analysis is often carried out by finite element method with proper creep and shrinkage models using step-by-step time integration. However as the full stress history prior to the time interval considered is necessary, with the increase in the number of time intervals used, the amount of computations increases dramatically. Therefore a new method using the shrinkage-adjusted elasticity modulus (SAEM) is introduced so that analysis can be carried out using one single step. Examples are presented to demonstrate its usefulness.