• Title/Summary/Keyword: flooring

Search Result 209, Processing Time 0.029 seconds

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

Quality Improvement Measures of Modular Public Rental Apartment Houses through Defects Analysis (모듈러 공공주택의 하자분석을 통한 품질 개선 방안)

  • Lee, Soon Guh;Kim, Gyu Yong;Nam, Jeongsoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.4
    • /
    • pp.425-436
    • /
    • 2024
  • Modular apartment houses are a relatively new approach to public housing in South Korea. While promising in terms of efficiency and potential cost benefits, initial occupancy and maintenance data highlight areas for improvement in quality control. Analysis of defects reported during occupancy and maintenance stages revealed a high prevalence of issues with wallpaper and flooring. This suggests a need for stricter quality control measures during the production and installation of these building components. Furthermore, maintenance data identified shortcomings in the waterproofing methods employed for roofs, as well as in the design and construction management of connections between the low-rise concrete frames and the modular units themselves, including balconies. These findings point towards the importance of meticulous design and rigorous construction management practices to ensure the long-term durability of these critical building elements. Finally, the research suggests that unifying responsibility for construction management by awarding contracts for both the frame and the modular units to a single company could improve overall quality control. This approach could potentially mitigate issues arising from divided responsibility and streamline communication channels. By addressing these quality control concerns, modular construction has the potential to become a more widely adopted and successful method for delivering public housing in South Korea.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.

Evaluation of Drying Properties and Yields of Domestic Quercus Species for Enhancing Utilization (국산 참나무류의 이용활성화를 위한 건조특성 및 가공수율 평가)

  • Chang, Yoon-Seong;Shin, Hyun-Kyeong;Kim, Sejong;Han, Yeonjung;Kim, Min-Ji;Eom, Chang-Deuk;Lee, Young-Geun;Shim, Kug-Bo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.622-628
    • /
    • 2017
  • In order to develop value-added utilization technology of domestic oaks the processing yield rate from the standing tree to the flooring material for the Quercus variabilis and Quercus mongolica were investigated. Also, to reduce drying time, improved drying schedule was applied and the physical properties were measured. The drying time was 173 hours in total, and the final moisture content was 5.39% (Quercus variabilis) and 4.17% (Quercus mongolica). The color difference of oak lumber before and after drying showed a significant change as ${\Delta}E$ value from 7 to 11. The shrinkage rates of Quercus variabilis and Quercus mongolica during drying were 8.1% and 8.5% in the tangential direction and 5.0% and 6.2% in the radial direction, respectively. The lumber manufacturing yield rate of sawn lumber was 30 to 40% and that of the final product was 8 to 15%. It is expected that the processing characteristics of the Quercus species investigated in this research could contribute to formulate an efficient production plan of domestic hardwoods that are still under utilization.

Effect of floor types (slat vs. litter) of group housing systems on sow behavior and environmental levels (모돈 군사 사육의 깔짚과 슬랏바닥의 행동 및 환경 수준 평가 비교)

  • Yang, Ka Young;Ha, Jae Jung;Kwon, Kyeong Seok;Kim, Jong Bok;Jang, Dong Hwa;Lee, Jun Yeob;Kim, Jung Kon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.388-394
    • /
    • 2020
  • This study was undertaken to evaluate and compare the status of animal welfare, environmental level, and sow behavior, by including two farmhouses with sow group housing but having different floor types, viz., litter floor and slat floor. Animal welfare level was evaluated for body and vulval wounds of sows. The environmental level was measured for a total of 4 months, assessing the concentrations of H2S, NH3 and CO2 inside the pig house, once a month. Results of this study indicate that the level of animal welfare, with respect to body and vulval wounds, was better in the concrete slat floor farmhouse (H) than in the litter floor farmhouse (K). Environmental levels obtained (in ppm) were: H2S (H, 1.0; K, 0.0), NH3 (H, 45.4; K, 1.3), and CO2 (H, 1102.3; K, 258.8), indicating higher levels in the H than in K farmhouse. Aggressive behavior was mainly encountered in the H farmhouse. These results indicate that the same group housing system, but with different flooring, results in changes pertaining to aggressive behavior and environmental levels. It is therefore necessary to study the behavior changes, welfare, and environmental levels while deliberating different floor types.

Influence factor analysis on the measurement of smoke density from floor materials in rolling stock (철도차량 바닥재 연기밀도 측정의 영향인자분석)

  • Kwon, Tae-Soon;Lee, Duck-Hee;Park, Won-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.629-634
    • /
    • 2016
  • In this study, we investigated the effect of factors that influence the measurement of smoke density using synthetic rubber flooring. The characteristics of rolling stock in an enclosed environment can cause enormous loss of life by smoke inhalation during fires inside passenger cars. The amount of smoke generation from interior materials for rolling stock is strictly restricted domestically and in other countries. Precise measurement of smoke density is therefore required to assess the fire performance of interior materials. Major factors that influence the measurement of smoke density include the uniformity of the specimen, the variations in conditions and instruments, and the operational and maintenance environment of the instruments. The contribution of factors was analyzed by estimating the uncertainty to investigate the contribution ratios of the major factors. The results show a contribution ratio of about 86% for the variation from the measurement of light transmission using a photomultiplier tube. Thus, this factor was the most representative for the measurement of smoke density. The contribution ratio of the other factors was low at about 11%, including irradiant flux conditions (${\pm}0.5 kW/m^2$) and the influence of the operational and maintenance environment of the instrument. These results were obtained using specimens with high uniformity.

Study on the Safety of Playground Flooring Made of Polyolefin Foam Waste and Rubber Paving (폐폴리올레핀 폼과 탄성 포장재로 구성된 어린이 놀이터 바닥의 안전성에 관한 실험적 연구)

  • Choi, Soo-Kyung;Jun, Myoung-Hoon;Lee, Do-Heun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.246-254
    • /
    • 2013
  • This study is purposed to verify the safety of the floor of the children's playground using polyolefin foam waste and rubber paving. The critical fall height, walking suitability, long term physical fatigue expectation and slipperiness were tested. Polyolefin foam wastes in thickness of 30mm, 50mm and 70mm were prepared with paving the rubber paving materials in 12mm and 15mm thickness respectively. The test on the critical fall height was carried out according to KS G 5758:2009. The floor hardness test equipment (O-Y HMA) was used for the test on hardness of the floor from a viewpoint of walking suitability and fatigue. A portable slipperiness tester (ONO PPSM) was used for slipperiness test. It was revealed from the test that the floor made of the polyolefin foam waste and rubber paving were considerably safe from a viewpoint of impact absorption. With regards to the hardness of the floor, it was shown the excellent performance in the aspects of walking and fatigue for male. But it was not suitable with walking on the shoes(middle heels) for female. And they will be very fatigue if they were in a long time walking or standing. As far as the slipperiness is concerned, it was shown that it was comparatively safe for the ordinary motions even though the surface was wet.

The Potential Impacts of Recent Developments in Timber Certification Schemes on the Korean Forest Products Trade (우리 나라 임산물무역(林産物貿易)에 대한 목재인증제(木材認證制)의 잠재적(潛在的) 영향(影響))

  • Joo, Rin Won;Lee, Seong Youn
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.3
    • /
    • pp.368-377
    • /
    • 2000
  • This study was conducted to examine the recent developments in timber certification schemes at global level such as FSC certification and ISO 14001 system and to analyze their potential impacts on the Korean forest products trade. Data and information on standards and procedure of timber certification and certified forest lands were collected from relevant papers, statistics and reports published by regional and international organizations. In order to analyze the impacts on the Korean forest products trade, questionnaire survey to the affected parties was conducted on acknowledge of key words relating to environment and trade and on the additional amount of willingness to pay for a labeled timber from environmentally sound and sustainably managed forests. Quantities of certified timbers supplied would continue to increase due to lots of timber certification schemes developed and implemented at national, regional and global levels and growing interests in certification from many countries. Demand for certified timbers, however, is far from clear at this stage. The deciding factor would be consumer reaction to the certified products. In the short run, the timber certification would have a little impacts on forest products imports into Korean markets since domestic purchasers do not have much interests in environment related trade measures and their willingness to pay price premiums for certified timbers is not high. However, it could be expected that timber certification has negative impacts on exports of forest products, such as flooring and plywood, to developed European markets where timber certification is used as a trade barrier.

  • PDF

Surface Temperature of Flooring Board Using Woodceramics with Sending an Electric Current (우드세라믹 통전에 의한 마루판의 표면온도 변화)

  • Oh, Seung-Won
    • Journal of agriculture & life science
    • /
    • v.46 no.1
    • /
    • pp.29-34
    • /
    • 2012
  • To examine possibilities to make use of woodceramics for the lower material of hot-floored ondol boards, woodceramics made from sawdust board with Pinus densiflora, put them in a wood frame and concrete block and heated them sending an electric current, and measured changes in surface temperature of a laminated floor board and a plywood floor board. As the sending an electric current to time passed, their surface temperature increased rapidly up to 20 minutes, and then gradually ascended. In terms of the surface temperature in the wood frame, the beginning temperature of a plywood floor board was higher than that of laminated floor one; however, as time passed, a laminated floor board's temperature rose, and after 60 minutes, it showed similar to the temperature of a floor board of lamination. On the other hand, the surface temperature in a concrete block showed that the laminated floor board was higher than the plywood floor board in both early and 60-minute later temperatures. With the lapse of time after switching off, the surface temperature of floor boards slowly dwindled up to 9 minutes, and from that time on, began to drop sharply. In terms of the descent speed of surface temperature, when woodceramics' surface temperature was adjusted at $70^{\circ}C$, the laminated floor board was the highest; when it was at $80^{\circ}C$, the plywood floor board was the highest, resulting in rapid descent speed of heat.

A Study on the Emission of VOCs in Parking Lot Floor Coating (주차장 바닥 코팅제의 휘발성유기화합물 배출에 관한 연구)

  • Lee, Seung-Chan;Yoon, Gil-Ho;Park, Yong-Soon;Kil, Bae-Su;Yoon, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.152-158
    • /
    • 2019
  • Measure the type and content of VOCs for A-company epoxy coating and B-company floor coating(Type A, B), which are used as flooring materials for parking lots. Than the VOCs used gas detectors to measure gas emissions, assuming the worst environment to reduce errors in external environments in the formaldehyde, toluene and xylene harmful to workers and tenants. As a result, A-company epoxy coating has the largest amount of VOCs, and compared to A-company epoxy coating, B-company floor coating of A type represented about 79% less and B type about 96% less. In addition, A-company epoxy coating was also the highest in gas emission measurement for formaldehyde, toluene and xylene using gas detector after 1 hour and 8 hours in closed environment conditions. B-company floor coating A type was less than A-company epoxy coating, which was about 42.3% less measured. And type B satisfied all TWA even in closed environment conditions.