• 제목/요약/키워드: floor spectra

검색결과 60건 처리시간 0.033초

Elastic floor response spectra of nonlinear frame structures subjected to forward-directivity pulses of near-fault records

  • Kanee, Ali Reza Taghavee;Kani, Iradj Mahmood Zadeh;Noorzad, Assadollah
    • Earthquakes and Structures
    • /
    • 제5권1호
    • /
    • pp.49-65
    • /
    • 2013
  • This article presents the statistical characteristics of elastic floor acceleration spectra that represent the peak response demand of non-structural components attached to a nonlinear supporting frame. For this purpose, a set of stiff and flexible general moment resisting frames with periods of 0.3-3.6 sec. are analyzed using forty-nine near-field strong ground motion records. Peak accelerations are derived for each single degree of freedom non-structural component, supported by the above mentioned frames, through a direct-integration time-history analysis. These accelerations are obtained by Floor Acceleration Response Spectrum (FARS) method. They are statistically analyzed in the next step to achieve a better understanding of their height-wise distributions. The factors that affect FARS values are found in the relevant state of the art. Here, they are summarized to evaluate the amplification and/or reduction of FARS values especially when the supporting structures undergo inelastic behavior. The properties of FARS values are studied in three regions: long-period, fundamental-period and short-period. Maximum elastic acceleration response of non-structural component, mounted on inelastic frames, depends on the following factors: inelasticity intensity and modal periods of supporting structure; natural period, damping ratio and location of non-structural component. The FARS values, corresponded to the modal periods of supporting structure, are strongly reduced beyond elastic domain. However, they could be amplified in the transferring period domain between the mentioned modal periods. In the next step, the amplification and/or reduction of FARS values, caused by inelastic behavior of supporting structure, are calculated. A parameter called the response acceleration reduction factor ($R_{acc}$), has been previously used for far-field earthquakes. The feasibility of extending this parameter for near-field motions is focused here, suggested repeatedly in the relevant sources. The nonlinearity of supporting structure is included in ($R_{acc}$) for better estimation of maximum non-structural component absolute acceleration demand, which is ordinarily neglected in the seismic design provisions.

Applications of Hilbert-Huang transform to structural damage detection

  • Chiou, Dung-Jiang;Hsu, Wen-Ko;Chen, Cheng-Wu;Hsieh, Chih-Min;Tang, Jhy-Pyng;Chiang, Wei-Ling
    • Structural Engineering and Mechanics
    • /
    • 제39권1호
    • /
    • pp.1-20
    • /
    • 2011
  • This study investigates the feasibility of detecting structural damage using the HHT method. A damage detection index, the ratio of bandwidth (RB) is proposed. This index is highly correlated or approximately equal to the change of equivalent damping ratio for an intact structure incurring damage from strong ground motions. Based on an analysis of shaking table test data from benchmark models subjected to adjusted Kobe and El Centro earthquakes, the damage detection index is evaluated using the Hilbert-Huang Transform (HHT) and the Fast Fourier Transform (FFT) methods, respectively. Results indicate that, when the response of the structure is in the elastic region, the RB value only slightly changes in both the HHT and the FFT spectra. Additionally, RB values estimated from the HHT spectra vs. the PGA values change incrementally when the structure response is nonlinear i.e., member yielding occurs, but not in the RB curve from the FFT spectra. Moreover, the RB value of the top floor changes more than those from the other floors. Furthermore, structural damage is detected only when using the acceleration response data from the top floor. Therefore, the ratio of bandwidth RB estimated from the smoothed HHT spectra is an effective and sensitive damage index for detecting structural damage. Results of this study also demonstrate that the HHT is a powerful method in analyzing the nonlinear responses of steel structures to strong ground motions.

자기부상열차의 소음저감 (Cabin Noise Reduction of a Maglev Train)

  • 김현실;김재승;강현주;강현주;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.849-854
    • /
    • 2001
  • Cabin noise reduction in maglev trains developed by KIMM is studied. Based on the measurements of cabin noise and acceleration levels during running and zero speed conditions, dominant noise sources are identified. After spectra characteristics of noise sources is investigated, efficient noise reducing methods are studied such as STL increasement of floor panels, sealing, and absorption treatment. It is found that the most important noise sources are VVVF inverter and SLIM in running condition. Since the noise sources are under the cabin floor, complete sealing and high STL of the floor panel are shown to be the most crucial factors in noise reduction. After polyurethan form (50t) is added for more sound absorption and sealing treatment, the cabin noise is reduced by 3-4 ㏈.

  • PDF

고진동수 지진동에 대한 원전 기기의 지진취약도 분석 (Seismic Fragility Analysis of NPP Components for High Frequency Ground Motions)

  • 최인길;서정문;전영선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.110-117
    • /
    • 2003
  • The result of recent seismic hazard analysis indicates that the ground motion response spectra for Korean nuclear power plant site have relatively large high frequency acceleration contents. In the ordinary seismic fragility analysis of nuclear power plant structures and equipments, the safety margin of design ground response spectrum is directly used as a response spectrum shape factor. The effects of input response spectrum shape on the floor response spectrum were investigated by performing the direct generation of floor response spectrum from the ground response spectrum. The safety margin included in the design ground response spectrum should be considered as a floor response spectrum shape factor for the seismic fragility analysis of the equipments located in a building.

  • PDF

Distribution of near-fault input energy over the height of RC frame structures and its formulation

  • Taner Ucar
    • Structural Engineering and Mechanics
    • /
    • 제85권1호
    • /
    • pp.55-64
    • /
    • 2023
  • Energy-based seismic design and evaluation methods are promising to be involved in the next generation design codes. Accordingly, determining the distribution of earthquake input energy demand among floor levels is quite imperative in order to develop an energy-based seismic design procedure. In this paper, peak floor input energy demands are achieved from relative input energy response histories of several reinforced concrete (RC) frames. A set of 22 horizontal acceleration histories selected from recorded near-fault earthquakes and scaled in time domain to be compatible with the elastic acceleration design spectra of Turkish Seismic Design Code are used in time history analyses. The distribution of the computed input energy per mass values and the arithmetic means through the height of the considered RC frames are presented as a result. It is found that spatial distribution of input energy per mass is highly affected by the number of stories. Very practical yet consistent formulation of distributing the total input energy to story levels is achieved, as a most important contribution of the study.

Evaluation of EC8 and TBEC design response spectra applied at a region in Turkey

  • Yusuf Guzel;Fidan Guzel
    • Earthquakes and Structures
    • /
    • 제25권3호
    • /
    • pp.199-208
    • /
    • 2023
  • Seismic performance analysis is one of the fundamental steps in the design of new or retrofitting buildings. In the seismic performance analysis, the adapted spectral acceleration curve for a given site mainly governs the seismic behavior of buildings. Since every soil site (class) has a different impact on the spectral accelerations of input motions, different spectral acceleration curves have to be involved for every soil class that the building is located on top of. Modern seismic design codes (e.g., Eurocode 8, EC8, or Turkish Building Earthquake Code, TBEC) provide design response spectra for all the soil classes to be used in the building design or retrofitting. This research aims to evaluate the EC8 and TBEC based design response spectra using the spectra of real earthquake input motions that occurred (and were recorded at only soil classes A, B and C, no recording is available at soil class D) in a specific area in Turkey. It also conducts response spectrum analyses of 5, 10 and 13 floor reinforced concrete building models under EC8, TBEC and actual spectral response curves. The results indicate that the EC8 and especially TBEC given design response spectra cannot be able to represent the mean actual spectral acceleration curves at soil classes A, B and C. This is particularly observed at periods higher than 0.3 s, 0.42 s and 0.55 s for the TBEC design response spectra, 0.54 s, 0.65 s and 0.84 s for the EC8 design response spectra at soil classes A, B and C, respectively. This is also reflected to the shear forces of three building models, as actual spectral acceleration curves lead to the highest shear forces, followed by the shear forces obtained from EC8 and, then, the TBEC design response spectra.

저속 주행시 자기부상열차의 실내소음저감에 관한 연구 (A Study Interior Noise Reduction of a Maglev Train at Low Speed)

  • 김현실;김재승;강현주;김봉기;김상렬
    • 한국소음진동공학회논문집
    • /
    • 제11권7호
    • /
    • pp.253-260
    • /
    • 2001
  • A Study of interior noise reduction in the magelv train is presented. Tarin speed of interest is low such that aero-dynamic noise is negligible and power supply system is a dominant noise source. Based on the measurements of interior noise and acceleration levels during running and zero speed conditions, dominant noise sources are identified. After spectra characteristics of noise sources are investigated several noise reducing methods are studied such as STL increasement of floor panels. sealing. and absorption treatment It is found that the most important noise sources are VVVF inverter and SLM in running condition, whereas air conditioner and DC/DC converter are dominant in zero speed. Sine the major noise sources are under the floor complete sealing and high STL of the floor panel are shown to be the most crucial factors in noise reduction After sound absorbing material, which is polyurethan foam of 50 mm thickness, is thickness, is attached to the downward side of the floor in addition to sealing treatment, the interior noise is reduced by 3~4 dB.

  • PDF

스펙트럼 형상이 원전 기기 지진취약도에 미치는 영향 평가 (Evaluation of Response Spectrum Shape Effect on Seismic Fragility of NPP Component)

  • 최인길;서정문;전영선;이종림
    • 한국지진공학회논문집
    • /
    • 제7권4호
    • /
    • pp.23-30
    • /
    • 2003
  • 최근 수행된 우리나라 원전 부지에 대한 지진재해도 해석 결과 작성된 등재해도 스펙트럼에서 고진동수 성분의 지진동이 매우 우세하게 나타나고 있다. 일반적으로 지진취약도 해석에서는 설계 스펙트럼에 내재된 보수성을 평가하기 위해 스펙트럼 형상계수가 사용된다. 본 연구에서는 입력지반운동 스펙트럼의 형상이 변화함에 따른 층응답스펙트럼의 형상 변화를 분석하였다. 이때 입력 스펙트럼으로부터 직접 층응답스펙트럼을 작성할 수 있는 직접법을 사용하였다. 본 연구 결과 건물 내부에 설치된 기기의 취약도해석에서는 입력스펙트럼에 내재된 보수성을 구조물의 고유진동수에 대한 스펙트럼 형상계수가 아닌 기기의 고유진동수에 따른 층응답스펙트럼 형상계수로 고려하는 것이 정확한 취약도해석 결과를 주는 것으로 나타났다.

낙하 충격 해석을 위한 명시법 과도응답의 가우스커널 평활화 기법 (Gaussian Kernel Smoothing of Explicit Transient Responses for Drop-Impact Analysis)

  • 박문식;강봉수
    • 대한기계학회논문집A
    • /
    • 제35권3호
    • /
    • pp.289-297
    • /
    • 2011
  • 명시적 유한요소법은 비선형성이 많은 대형 문제를 푸는 데는 꼭 필요하지만 종종 그 결과의 해석에 있어서는 어려움이 수반된다. 특별한 경우, 가속도의 과도응답은 극심한 불연속, 과도한 노이즈 또는 앨리어싱이 발생하여 평가가 불가능할 때도 있다. 본 논문에서는 유한요소법의 명시적분에 의한 과도응답 및 응답스펙트럼의 새로운 후처리기법을 제안한다. 해석기에 의한 가속도 거동의 수치적인 에러를 제거하고 물리적인 가속도를 추출하기 위하여 가우스커널을 이용하는 평활화법을 제안하였다. 이 평활화는 신호처리 필터링 기법과 같이 복잡한 주파수에 대한 고려가 없이도 속도에 대한 결과와 응답스펙트럼을 참조함으로써 행해진다. 특히 가우스커널 평활화는 가속도의 피크 값을 잘 나타내면서도 평활도가 우수하였다. 제안된 평활화법에 의하여 부드러운 가속도는 물론 이를 이용하여 설계에서 필요한 층 응답스펙트럼을 구할 수 있다.

원전 주제어실 삼차원 면진시스템 수직방향 저감효과 시험연구 (Experimental Study on Vertical Reduction Effectiveness of Main Control Room of NPP using 3-Dimensional Isolation System)

  • 함경원;이경진;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.417-423
    • /
    • 2006
  • The seismic characteristics with 3-Dimensional isolation systems have been studied using a shaking table system. In this study, we made nuclear power plant main control room floor systems and several seismic shaking table tests with and without isolation systems were conducted to evaluate floor isolation effectiveness. Isolation systems have showed large reduction effectiveness in acceleration and response spectra with x and z direction respectively, but horizontal isolation is more effective than vertical one It is required to make isolation systems of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such isolation systems, it is recommended that much consideration should be taken into account when applied to main control room of NPP.

  • PDF