Evaluation of Response Spectrum Shape Effect on Seismic Fragility of NPP Component  

최인길 (한국원자력연구소)
서정문 (한국원자력연구소)
전영선 (한국원자력연구소)
이종림 (한전 전력연구원)
Publication Information
Journal of the Earthquake Engineering Society of Korea / v.7, no.4, 2003 , pp. 23-30 More about this Journal
Abstract
The result of recent seismic hazard analysis indicates that the ground motion response spectra for Korean nuclear power plant site have relatively large frequency acceleration contents. In the ordinary seismic fragility analysis of nuclear power plant structures and equipments, the safety margin of design ground response spectrum is directly used as a response spectrum shape factor. The effects of input response spectrum shape on the floor response spectrum were investigated by performing the direct generation of floor response spectrum from the ground response spectrum. The safety margin included in the design ground response spectrum should be considered as a floor response spectrum shape factor for the seismic fragility analysis of the equipments located in a building.
Keywords
seismic fragility, spectrum shape factor; input ground motion; floor response spectrum;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Reed, J. W., Kennedy, R.P., Buttemer, D. R, ldriss, I. M., Moore, D. P., Barr, T., Wooten, K. D., and Smith, J. E., "A Methodology for Assessment of Nuclear Power Plant Seismic Margin(Revision 1)," EPRI NP-6041-SL, 1991.
2 최인길, 서정문, 전영선, "입력스펙트럼 형상이 층응답스펙트럼에 미치는 영향 평가", 2002 추계 한국원자력학회 학술발표회 논문집, 2002.
3 Singh, M. P. and Sharma, A. M, "Seismic Floor Spectra by Mode Acceleration Approach," Journal of Engineering Mechanics, ASCE, Vol. 111, No. 11, 1985.
4 Newmark, N. M. and Hall, W. J., "Development of Criteria for Seismic Review of Selected Nuclear Power Plants," NUREG/CR-0098, 1978.
5 Singh, M. P., "Seismic Design Input for Secondary Systems," Journal of the Structural Division, ASCE, Vol.106, No. ST2, 1980.
6 조양희, 조성국, "모드기여도를 고려한 복수모드구조물의 지진취약도분석", 한국지진공학회 논문집, 제6권, 제4호, 2002, pp. 15-22.   과학기술학회마을
7 Kennedy, R. P. and Ravindra, M. K, "Seismic Fragilities for Nuclear Power Plant Risk Studies," Nuclear Engineering and Design, Vol. 79, 1984, pp. 47-68.   DOI   ScienceOn
8 최인길, 전영선, 연관희, "등재해도 스펙트럼을 이용한 지진취약도 분석" , 한국원자력학회 2002년 춘계학술발표회, 2002.
9 Chang, S. P., Seo, J. M, Kim, J., and Lee, J. R, "Effects of PSDF Forms on Floor Response Spectra Generation in Direct Solution Method," Transaction of SMiRT 11, Vol. K, K10/3, 1991.
10 US NRC Regulatory Guide 1.60, Design Response Spectra for Seismic Design of Nuclear Power Plants, 1973.
11 Llambias, J. M, "The Use of the Uniform Risk Spectra in the Seismic PSA for a PWR Power Station," Nuclear Engineering and Design, Vol. 154, 1995.
12 Reed, J. W. and Kennedy, R. P., Methodology for Developing Seismic Fragilities, EPRI TR-103959, 1994.
13 Biggs, J. M, "Seismic Response Spectra for Equipment Design in Nuclear Power Plants," Proceedings 1st International Conference on Structural Mechanics in Reactor Technology, Berlin, Germany, Paper K4/7, 1971.
14 McGuire, R. K, Silva, W. J., and Costantino, C. J., "Technical Basis for Revision of Regulatory Guidance on Design Ground Motions : Hazard-and Risk-consistant Ground Motion Spectra Guidelines," NUREG/CR-6728,2001.
15 Choi, I. K, Choun, Y. S., Seo, J. M, and Yun, K. H., "Reevaluation of Seismic Fragility Parameters of Nuclear Power Plant Components Considering Uniform Hazard Spechum," Journal of the Korean Nuclear Society, Vol. 34, No. 6,2002.   과학기술학회마을
16 Singh, M. P., "Generation of Seismic Floor Spectra," Journal of the Engineering Mechanics Division, ASCE, Vol. 101, No. EM5, 1975.
17 Reed, J. W, Kennedy, R. P., and Lashkari, B., "Analysis of High-Frequency Seismic Effects," EPRI TR-102470, 1993.