• 제목/요약/키워드: floor mortar

검색결과 76건 처리시간 0.024초

양생 조건이 바닥용 건조 모르타르의 압축강도에 미치는 영향 (Effect of Curing Conditions on Compressive Strength of Dry Mortar for Floor)

  • 정용;김두혁;박창환;조성현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.377-378
    • /
    • 2023
  • This study examined the effect of curing conditions on the compressive strength of dry mortar for floor. The compressive strength according to the relative humidity during curing was compared, and the influence of expansive additives on compressive strength under water curing was reviewed. As a result, low relative humidity conditions during curing was not effective in improving the compressive strength of dry mortar for floor, and it was judged that the continuous hydration reaction insufficient due to lack of the moisture supply. In order to improve compressive strength, high relative humidity maintenance was found to be an important factor. However, under water curing conditions, the compressive strength has decreased as a result of continuous volume expansion due to the use of the expansive additives.

  • PDF

단면 회복용 중량 모르타르를 사용한 철근콘크리트 슬래브의 음압 및 진동 특성 (Sound Pressure and Vibration Characteristics of Reinforced Concrete Slab with Heavy Weight Mortar for Cross-section Recovery)

  • 김재성;김진만
    • 한국건설순환자원학회논문집
    • /
    • 제12권3호
    • /
    • pp.298-305
    • /
    • 2024
  • 본 논문은 철근콘크리트 슬래브의 바닥 충격음을 개선하기 위한 기초연구이다. 시공에 의해 두께의 차이가 발생하는 경우를 고려하여 철근콘크리트 슬래브의 단면을 모르타르로 회복시켰을 경우 차음 특성의 변화를 분석 하였다. 분석 대상 주택은 평면형식이 다른 84 type와 59 type의 2종류로 하였으며, 철근콘크리트 슬래브 위에 단면을 회복하기 위해 중량모르타르로 단면 회복용 모르타르 시공할 때를 철근콘크리트 슬래브 단독과 일반 모르타르로 단면 회복용 모르타르 시공한 경우와 비교하여 진동가속도레벨과 음압의 차이를 측정하였다. 모르타르를 타설 후 슬래브에 대해 진동가속도 레벨을 측정한 결과, 84 type 63 Hz에서 CS 모르타르가 66.4 dB, ES 모르타르가 66.1 dB로 일반 모르타르에 비해 2 dB 이상 낮게 나타났다. 또한 철근콘크리트 슬래브 단독과 비교할 때 CS 모르타르가 5.5 dB, ES 모르타르가 4.6 dB이 저감되어 비교적 우수한 값을 보였다. 바닥충격음 음압은 결과의 경우, 84B type이 63 Hz에서 CS 모르타르와 일반 모르타르가 67.3 dB로 유사하게 나타났으며, 철근콘크리트 슬래브 단독 대비 저 감량은 CS 모르타르가 3.6 dB, ES 모르타르가 2.7 dB, 일반 모르타르가 1.4 dB 저감되었다. 철근콘크리트 슬래브의 두께를 보상하기 위하여 모르타르를 타설함으로서 진동가속도레벨 및 바닥충격음은 감소하였으며, 동제련 슬래그 잔골재를 사용한 중량모르타르를 사용할 경우 상대적으로 우수한 성능을 발현하는 것으로 나타났다.

폐 FRP를 혼입한 바닥미장모르타르의 물리적 특성 (Physical Properties of Plastering Mortar with Waste FRP for the Floor)

  • 김성환;이국재;박종원;백주현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.17-20
    • /
    • 2008
  • This study investigated the fundamental properties and cracking shapes of mortar for the floor after Mock-up test with FRP as wastes of crafts. For the flowability of fresh mortar without FRP, it was favorable compared with fresh mortar using FRP, and the drop time at O-Lot was similar to the flowability. For the compressive strength of fresh mortar with FRP, it was increased about 10% compared with plain. The flexible strength was also increased on fresh mortar with FRP. On the cracking shape, there was many penetrated crack in all directions on plain. In the case that FRP was used, it seemed to have excellent resistance to the crack occurrence because there was no directive crack at a limited part.

  • PDF

난방을 위한 바닥용 건조 시멘트 모르타르의 혼합수량비 변화에 따른 품질 특성 (Quality of Dry Cement Mortar for Floor Heating Depending on Water-to-Dry Mortar Rutio)

  • 박상준;황인성;이건철;김종
    • 한국건축시공학회지
    • /
    • 제21권3호
    • /
    • pp.181-188
    • /
    • 2021
  • 본 연구는 바닥 난방을 위한 바닥용 건조 시멘트 모르타르의 현장 혼합수량비(W/DM) 변화에 따른 각종 품질특성을 검토한 것이다. 연구결과, 바닥용 건조 시멘트 모르타르의 현장 시공은 현장에서 혼합하는 혼합수량의 증가에 따라 플로가 증가하고, 단위용적질량이 감소하는 일반적인 경향이며, 압축강도 및 건조수축 길이변화율은 혼합수량의 변동에 따라 바닥용 DM의 품질에 크게 영향을 미치기 때문에 적정 W/DM의 관리가 바닥용 DM의 시공 품질 확보에 있어서 매우 중요하다. 따라서, 바닥용 DM의 현장 시공시 작업자의 작업성만을 고려한 과도한 현장 W/DM 증가는 과도한 블리딩 및 재료분리 등으로 인해 바닥용 DM의 경화 후 품질저하를 초래할 수 있으므로 주의가 필요하다. 이상으로, 본 연구 범위의 실험결과를 종합하면, 현장 시공 시 바닥용 DM의 품질확보를 위한 현장 품질관리 기준으로는 W/DM 약 20%가 바람직한 것으로 판단되고, 이를 바탕으로 현장 여건에 따라 적정 혼합수량이 관리될 수 있다면 바닥용 DM의 양호한 품질확보가 가능할 것으로 판단된다.

공동주택 바닥 목재 마루판 들뜸 하자 사례조사 연구 (A Case Study on the Debonding Defect of Wood Floor Board in Apartment House)

  • 최성용;한민철;한천구
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2008년도 정기학술발표대회 논문집
    • /
    • pp.914-917
    • /
    • 2008
  • 본 연구에서는 공동주택 바닥 나무 마루판 공사의 하자 사례를 조사하고 이중 가장 많은 발생빈도를 보이는 들뜸 현상에 대하여 원인분석 및 방지 방안을 검토하고자 하였다. 사례조사 결과 목질마루판 공사에서 하자요인으로써는 마루판 들뜸, 찍힘, 틈새, 갈라짐 등이 나타났고, 극중 마루판 들뜸 현상이 전체 하자비율의 72 %정도로서 가장 큰 문제점으로 나타났다. 마루판 들뜸현상이 발생하는 가장 큰 원인으로써 는 바닥 모르터의 건조수축과 목질마루판의 팽창을 특수 있는데, 모르터의 건조수축의 경우 바닥 모르터를 충분히 건조시키지 않은 상태에서 목질마루판을 시공함으로써 발생하게 되고, 목질 마루판의 팽창의 경우 목재 하지 및 주위 환경의 수분에 영향을 받아 발생하게 된다. 따라서, 목질마루판을 시공하기 전에 바닥 모르터의 양생시간을 충분히 고려하여 (약 4주간) 마루판 시공을 실시하고, 목질 마루판의 함수율이 목재 하지의 함수율로부터 4 %이상 벗어나지 않게 하며 목질마루판의 함수율을 5 % 이내로 관리하게 되면, 목질마루판의 가장 큰 문제점인 마루판 들뜸 현상은 방지할 수 있을 것으로 판단된다.

  • PDF

페로니켈슬래그 잔골재의 바닥용 건조모르타르 적용성 평가 (Applicability of Ferro-nickel Slag Sand for Dry Mortar in Floor)

  • 조봉석;김원기;황인성;구경모
    • 한국건축시공학회지
    • /
    • 제19권2호
    • /
    • pp.105-112
    • /
    • 2019
  • 페로니켈슬래그 잔골재는 천연 잔골재와 유사한 특성이 있어 국내 외적으로 콘크리트 구조물에 사용되고 있으나 그 용도와 연구의 영역이 한정적이다. 이에 본 연구에서는 FNS의 활용성 확대와 모르타르제품의 성능개선을 목적으로 바닥용 건조모르타르에 대한 FNS의 적용성을 검토하고자 하였다. 실험 결과, FNS는 흡수율이 낮고 구형의 입형이며 표면이 유리질 피막의 특성이 있어 모르타르의 플로을 향상시켰다. 또한 골재 자체의 높은 강성은 몰탈 압축강도의 향상 및 수축저감 효과를 나타내어 균열저감 등의 품질향상에 기여할 것으로 판단된다. 뿐만 아니라 천연 잔골재를 사용한 모르타르와 비교하여 FNS를 적용하는 경우 동등수준 이상의 충격음 차단성능을 확보할 수 있었다.

An Experimental Study on the Thermal Performance of Cement Mortar with Granulated PCM

  • Jeong, You-Gun;Park, Ki-Bong;Lee, Han-Seung
    • 한국건축시공학회지
    • /
    • 제12권5호
    • /
    • pp.548-557
    • /
    • 2012
  • In this study the thermal performance of G-PCM replaced for find aggregate in mortar specimens was evaluated using TG-DTA. As a result, it was found that when solid changed into liquid, it absorbed heat, and when liquid changed into solid, it radiated heat. In addition, the fluidity and the compressive strength of mortar with G-PCM can be applied to the floor mortar and a wall finish material. Also the higher the replacement ratio, the larger the latent heat capacity. It was found that the mortar with G-PCM slowed the increase and decrease of temperature. Thus, the duration of pleasant indoor temperature is extended by the floor and wall mortar with G-PCM. In conclusion, G-PCM is expected to reduce the heating energy consumption.

발포유리 혼합기포 콘크리트의 바닥충격음 차단성능 영향에 관한 연구 (The Effect of Aerated Concrete containing Foam Glass Aggregate on the Floor Impact Sound Insulation)

  • 윤창연;정정호;김명준
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.414-422
    • /
    • 2013
  • As structure-borne sound, the floor impact sound is one of the serious noises in residential building. Most of heating system applied to the typical Korean residential building is floor heating system which is called ondol. The ondol usually consists of finishing material, mortar with heating coil, light-weight aerated concrete and reinforced concrete. This study focused on the isolation of heavy-weight impact sound and modification of mortar and light-weight aerated concrete. Specifically the glass foam aggregate was added on light-weight aerated concrete. Also, water-cement ratio and amount of cement on mortar were revised. The sound pressure level of heavy-weight impact was measured in reverberation chamber using both bang-machine and impact ball. The size of specimen was 1 m by 1 m. Substitution ratio of glass foam aggregate on light-weight aerated concrete shows relationship with heavy-weight impact sound pressure level. In addition, heavy-weight impact sound pressure level was decreased with increment of water-cement ratio and amount of cement on mortar.

현장 시공성 개선을 위한 롤타입 건식바닥난방시스템 개발 (A Study on the Development of Rolled Dry Floor Heating System for Improving Workability)

  • 이규동;김준호;정창호;김동우;小川慶一郞
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.177-180
    • /
    • 2012
  • Korea residential housing generally use wet floor heating system 'Ondol' which consist of insulation cushioning, lightweight foamed concrete, hot water pipe and mortar on top of reinforced concrete slab. Wet floor heating system's installation process is too complicate and difficult to supervise field for continuing assurance quality. Also, this method has a huge impact on the progress of construction because it take a long time to cure finishing mortar and lightweight foamed concrete. Therefore, it is considered a disturbance factor of reduction of construction duration for enhancing competitiveness. In this study, we conducted an experiment about the radiant heat performance and temperature difference on upper panel of rolled dry floor heating systems which is jointly developed by Kolon global and Sumisho Metalex for remodeling housing, studio apartment and the urban-life housing.

  • PDF

균열저감형 바닥마감전용 모르터의 건조수축특성 연구 (A Study on the Dry-Shrinkage Properties For Floor Mortar With Crack-Reducing)

  • 이종렬;이웅종;채재홍;박경상;김기수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.175-180
    • /
    • 1999
  • The heating system of korea apartment house is called Ondol. The surface finishing mortar of this floor system typically used the cement based mortar, where the surface finishing mortar easily appears the crack. To order to crack control, the cement that added expansive additive used to reducing dry-shrinkage. For the surface finishing mortar, the types of shrinkage is known as plastic shrinkage, dry-shrinkage and autogenous This experimental study is to investigate the difference on dry-shrinkage of the cement that added expansive additives and OPC. The test method is varied the ration of water/cement (W/C) and the ratio of sand/cement(S/C). For OPC, The increase of the ratio of S/C is reduced dry-shirnkage but for the cement that added expansive additives, the increase of the ratio of S/C is augmented dry-shrinkage For OPC, The increase of the ratio of W/C is augmented dry-shrinkage but for the cement that added expensive, the increased of the ratio of W/C is reduced dry-shrinkage.

  • PDF