• Title/Summary/Keyword: floor impact sound

Search Result 266, Processing Time 0.036 seconds

Analysis on Results evaluated by "Housing Performance Grading System" in Korea (주택성능등급 인정 사례의 부문별 평가 결과 분석)

  • Lee, Sung Ok
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.55-66
    • /
    • 2010
  • The government is enacted "Housing Performance Grading Indication System" from qualitative housing supply policy and performance of housing under the background of looking for new plan to secure good housing stock and housing performance. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are sound insulation related grading(Light-weight impact sound insulation, heavy-weight floor impact sound insulation, noise emission in bathroom, airborne sound insulation for wall between units), Long-life housing related grading(flexibility, remodeling & maintenance, durability), environment related grading(landscape, indoor air quality and ventilation, energy performance), Living environment related grading(common resident facilities such as playground and consideration for the socially underprivileged such as the aged), Fire fire prevention grading(fire fire prevention). The purpose of this research is to analyze characteristics and assessment results of 20 detailed performance items on "Housing Performance Grading Indication System" which was enforced 240 cases from Jan 9th, 2006 to Sep 30th, 2010. The analysis of approval condition of detailed performance items will be important comments for understanding the current domestic level and development of technology.

Deviation of Heavy-Weight Floor Impact Sound Levels According to Measurement Positions (마이크로폰의 위치에 따른 중량 바닥충격음레벨의 편차)

  • Oh Yang-Ki;Joo Moon-Ki;Park Jong-Young;Kim Ha-Geun;Yang Kwan-Seop
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.49-55
    • /
    • 2006
  • Measurement of impact sound insulation of floor, by current Korean Standard KS F 2810-2. is to be made with peak levels over 4 point in a receiving room. But it is often the case that there is inconsistency in results at various receiving points in the receiving room. Such variations obviously have effects on the repeatability and reproducibility of measured data. The result shows that there are even 10 dB deviations in 63Hz octave band frequency range and relatively less variations are occurred in other low frequency ranges. Such variations seems to be coming from modal overlaps of the receiving room. According to current rating method of floor impact sound. KS F 2863-2, that may affect on the single number latins scheme. From the result of tests in this study, there are 2dB to 6dB differences in the sin91e number with the combination of measurement points. This means that the reduction of measurement variations from the microphone positions is needed for a better credibility of measurement results.

The numerical analysis of heavy-weight impact noise for an apartment houses considering acoustic mode (Acoustic mode 를 고려한 공동주택 중량충격음 소음해석)

  • Mun, Dae-Ho;Hwang, Jae-Seung;Park, Hong-Gun;Hong, Geon-Ho;Im, Ju-Hyeuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.394-402
    • /
    • 2009
  • To investigate the heavy-weight impact noise of apartment houses, numerical analysis was performed. The analysis acoustic pressure consider acoustic mode by finite element method. The variables considered effecting on the acoustic pressure are the Acoustic mode, acoustic damping, and the impulse load. The heavy-weight impact noise is a changeable value in the room. Since the most part of the frequency component of heavy-weight impact noise has low frequency. The noise in low frequency is related to the vibration of structure, the reflection of acoustic wave caused by wall and the standing wave called by acoustic mode. The prediction by the numerical analysis was verified with test result of the heavy weight-impact noise at apartment houses.

  • PDF

Analysis of airborne sound insulation performance by the experiment using small size specimen (축소시편 실험을 통한 공기전달음 차단성능 분석)

  • Kim, Hang;Park, Hyeon Ku;Goo, Hee Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • The residents' demand for the comfortable life is promoting development of wall and window which has high sound insulation performance. To develop wall system, various aspects should be considered on the environment, material, construction and structure. Especially focusing on the acoustical view, the economical solution is one of the most critical point. Recently the interest on the partition wall is being increased, because it is useful for the Rahmen type apartment which is considered as an alternative to reduce floor impact sound. This study examines simplified measurement method of airborne sound insulation applied small size specimen, in order to save money to be used for the standard specimen then to promote the development process. The results showed that the simplified method could be effective for the wall system the sound insulation performance upto Rw 50 dB, and for the judgement of rank order of sound insulation performance of the similar wall type while developing.

A Study on the Evaluation Factors for Diffuser Noise of HVAC (공기조화 취출구 소음의 평가요인에 관한 연구)

  • Park, Hyeon-Ku;Kim, Hang;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.149-155
    • /
    • 2006
  • There are various types of noise around us such as road traffic noise, aircraft noise and floor impact sound, equipment noise, etc. Researches on the noise criteria and the evaluation method for the diffuser noise of HVAC are insufficient. dB(A) and NC values represented in ASHRAE guide book are applied as a noise criteria for diffuser noise, which have some problems like that the values between dB(A) and NC have deviation even if the sound is same one. Therefore, the evaluation method should be considered and proposed based on the subjective responses. From these reasons, this study aimed to analyze the evaluation factors for the diffuser noise of HVAC reflected on the subjective responses by surveying vocabularies and grouping them with factor analysis.

A Study on the Evaluation for Energy Characteristic of Absorber Floor Insulation of Apartment House (공동주택 층간단열 완충재의 열에너지 특성의 관한 연구)

  • Choi, Dong-Hyuk;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon;Cho, Woo-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.712-717
    • /
    • 2009
  • Ondol is a tradtional Korea heating system with a long history. The ondol heating system is a default in ordinary houses and high-rise apartment alike. But Intensified Architecture Law insulation standard can't satisfied standard insulation only light weight concrete in ondol. The between light weight concrete and slab apply EPS insulation is construct for generate a method of construction. The standard insulation for floor heating system is responsible but complicate construction thermal transmittance and absorber, deteriorate the cost and decreasing the performance insulation & impact floor sound. In study on the evaluation decrease heating-load of floor construction of the insulation & absorber that improvement floor a Apartment house.

  • PDF

Variation Characteristics of Floor Impact Sound by Ceiling Structures in Apartment Buildings (공동주택에 천장구조에 의한 바닥충격음 변화특성에 관한 연구)

  • 조창근
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.13-16
    • /
    • 1993
  • 본 연구에서는 공동주택의 바닥충격음 차음성능 향상을 위한 설계자료의 제시를 위해 천장구조가 서로 다른 공동주택을 대상으로 경량 및 중량 바닥충격음의 현장측정을 통하여 공동주택의 천장구조에 의한 바닥충격음 변화특성을 분석하고 차음성능을 평가하였다. 측정대상 건물에서 천장을 설치한 경우가 비교적 높은 충격음 차음성능 분포를 보이는 것으로 나타났으며, 바닥슬래브 하부 천장에 공기층과 완충재를 함께 설치하는 것은 기존 공동주택 등에서 경량 및 중량 바닥충격음 차음성능을 향상시키기 위한 효과적인 방안임을 확인하였다.

  • PDF

Measurement uncertainty in heavy-weight floor impact sounds (측정 불확도에 따른 중량충격음 측정편차에 관한 연구)

  • Yoo, Seung-Yup;Kim, Yong-Hee;Sim, Myoung-Hee;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.826-829
    • /
    • 2008
  • In a field measurement, measurement errors are produced by measuring environments and systematic errors in the measurement procedure. Measurement errors can be expressed as a measurement uncertainty. In this study, the measurement uncertainty and various measuring factors are investigated in heavy-weight impact sounds. According to KS 2810-2, the model functions, which is the estimation of the maximum SPL measurement in each octave band frequency, are determined. From this estimation model, 3.53dB is shown in 63Hz. This level is caused by the sound field of the receiving room, which does not meet the diffusing field.

  • PDF