A study on the establishment of vibration conditions of a composite deck floor with panel heating systems for a steel structure (Panel heating을 적용한 철골조 건물의 합성테크 진동조건 설정에 관한 연구)

  • Park, Jin-Young;Kim, Hee-Cheul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.972-977
    • /
    • 2000
  • One of the major differences of Korean residential building compared with other countries is a rigid diaphragm of a floor due to the panel heating system. An increment of a gravity floor load might cause vibration problem when the composite floor system is introduced to the panel heating system. Since the noise criteria of a residential building is lower than that of an office building, the development of a noise absorbing system should be preceded. The response evaluation was performed for the finished floor, that is with panel heating and noise absorbing system. The natural frequency was obtained both from an experimental study and an analytical study. An appropriate vibration condition of a floor with panel heating and noise absorbing systems was evaluated from this study.

  • PDF

A review on the effect of a floor heating system on the human body (기존문헌조사에 의한 바닥난방의 인체영향에 관한 연구)

  • 최영식
    • Journal of the Korean housing association
    • /
    • v.3 no.1
    • /
    • pp.85-92
    • /
    • 1992
  • A floor system have played a major part in the living in Korean house. It is an essential element in the residential houses. Uufortunately, a design method of the floor heating system for the human thereat comfort has not established in Korea system. This paper aims to review the previous researches to find the issue for the futher study of comfort floor heating design. The following results were obtained: 1) Nevins et at conducted experiments on the effect of the comfortable of floor and air temperatures on the psychological responses by a large number of subjects. Its objective was to find the combined condition to obtain thermal comfort for sedentary posture.7here has never been researches regarding a sitting Person on the heated floor. 2) Some investigation in Japan on the effect of floor heating system on a sitting person on the floor have been conducted for these years, but they are net based on the human heat balance but on only psychological responses. 3) Hirayama et al developed an indication method of the effect of heat conduction on the sedentary person.4) There are few researches on the human thermal comfort compared whth indoor environmental researches on mechanical controls in Korea. Thus, the further study on the followings in needed the estimaiing of heat conduction between tile hunman body and a floor, developing an index expressed the combined effect of convection, radiation and conduction and its associated experiments.

  • PDF

Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the ToP Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Closed - (공동주택의 하절기 개구부 밀폐 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석)

  • Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.45-53
    • /
    • 2004
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample houses. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained the brief results as follows. Indoor air temperature at the top floor unit is $1.2\sim2.2^{\circ}C$ higher than that of middle floor unit. The evaluation of the indoor thermal comfort index at each sample rooms reveals notable thermal differences between the two units. Top floor units need more cooling load during the summertime compared to middle floor units. Therefore, solutions to reduce solar Heat gain at top floor units to be considered.

Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the Top Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Opened - (공동주택의 하절기 자연환기 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석)

  • Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature, globe temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample units on the condition that all the openings of the units are opened. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained three brief results as follows. Indoor air temperature difference between the two sample units shifts a day. Indoor air temperature at the top floor unit is $0{\sim}1.8^{\circ}C$ higher than that of the middle floor unit from 12:00 p.m. to 12:00 a.m. and $0{\sim}2.8^{\circ}C$ lower from 12:00 a.m. to 12:00 p.m. The evaluation of the indoor thermal comfort index and the globe temperature shows similar results as the indoor air temperature measuring. Results of this experiment verified the actual existence of indoor air temperature difference between the top floor unit and the middle one and this difference comes from the heat storage of the roof.

Effect of Pen Floor Condition Depending upon Housing Orientation on the PerFormance of Finishing Hanwoo Steers (우사의 향방에 따른 사육장 바닥면의 조건이 비육말기 거세한우의 생산성에 미치는 영향)

  • 김동균;정다운
    • Journal of Animal Environmental Science
    • /
    • v.10 no.1
    • /
    • pp.37-46
    • /
    • 2004
  • In order to investigate the effect of floor condition on the fattening performance of cattle, sixteen finishing Hanwoo steers of weighting 570kg were fed for 16 weeks to slaughter on two types of sawdust bedding pen oriented to the south(SP) and the north(NP) then obtained following results. The floor condition of SP roofed by transparent material was dry and flat during overall experimental period, whereas, that of NP roofed by solid slate was muddy and rough even in summer and fall, and then frozen in winter period resulted in interfering with the locomotion and resting behavior of steers. Average daily dry matter intake of steers was not different between tow treatments, however, the average daily gain of steers in NP and SP was 0.64kg and 0.75kg, respectively, meaning that gained 14.3% less for the NP group(p<0.05), accordingly, feed requirement(feed/gain) and TDN/gain increased by 15.9% and 15.5%, respectively. No significant differences were found in slaughter weight, carcass weight, dressing percentage, meat yield index and meat quality traits between two treatments. In conclusion, this study revealed that poor floor condition of feeding pen could decrease weight gain and feed efficiency of cattle by increasing energy consumption for locomotion and conductive energy loss while resting on the floor surface. These results indicates that housing orientation of cattle shed and the selection of roof material are important factors in beef cattle production.

  • PDF

A Study on the Characteristics of the Housing Floor Plan for the University students in Rural Area. -Base on Bong-po Ri, Cheon-jin Ri- (농촌지역 대학생 전용 다가구 주택의 공간 특성에 관한 연구 -강원도 고성군 봉포리, 천진리를 중심으로-)

  • Kim, Jung Bum
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.3 no.2
    • /
    • pp.49-56
    • /
    • 2001
  • The purpose of this study is to provide a practical guide for optimum residential and useful architectural condition in a regional area. The data has been collected through survey from exist Housing of a Go-sung Gun Toa-Sung Mun area. Those 21 Housing samples are collected, and are analyzed by standard Architectural codes, country Architectural codes and regulations This study has been processed in analysis of the unit planning and codes condition of each housings, and situation analysis through the practical investing. As a results of this study, the Housing floor plan in rural area should reflect user's needs and functional unit plan. Especially, the unit planning have a good residental environments. An instance, laundry and balcony space. These result will become basic data for the future architectural design in the Housing floor plan in rural area.

  • PDF

A Case Study on the Debonding Defect of Wood Floor Board in Apartment House (공동주택 바닥 목재 마루판 들뜸 하자 사례조사 연구)

  • Choi, Sung-Yong;Han, Min-Cheol;Han, Cheon-Gco
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.914-917
    • /
    • 2008
  • This paper was to discuss the case and cause of debonding defect of wood floor board in apartment house by investigating actual survey. Most frequent defect in wood floor board was debonding of floor board. Scratch, gap and crack of floor board were also found in floor board installment work. Causes of debonding of floor board is shrinkage of cement mortar beneath floor board and expansion of floor board. Haste in floor board work did not provide enough time to dry cement mortar fully, which led to continue to dry after the installment of floor board. It caused moisture movement toward wood floor board. Accordingly, Before floor board work, careful consideration on moisture condition of cement mortar and enough curing time to eliminate the effect of moisture are taken into.

  • PDF

Performance Evaluation of the Floor Impact Sound Insulation in Steel Framed Modular House (강재프레임 모듈러주택의 바닥충격음 성능평가)

  • Chun, Young-Soo;Bang, Jong-Dae;Kim, Gap-Deug;Yoo, Song-Lee
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.81-89
    • /
    • 2014
  • This paper presents various attempts to secure the floor impact sound insulation performance on the dry floor system of steel framed modular house that lately attracted domestic attention. Test results show that in the condition of using dry floor system of D31(D32), the light-weight impact noise performance records the top level in the floor impact sound insulation performance grading system. the heavy-weight floor impact noise performance meets the minimum sound level limit in the floor impact sound insulation performance grading system that enacted regulation on housing construction standards.

Development of ceiling construction methods reduced floor impact sound (바닥충격음 저감이 가능한 천장 공법 개발)

  • Kim, kyungho;Kim, sunghoon;Ryu, jongkwan;Lee, jongin;Kim, yongmin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.203-207
    • /
    • 2014
  • According to the advanced study, Increase of ceiling air space could cause increase of floor impact sound by air-spring effect. So in this research, we studied the increase of floor impact sound caused by ceiling air space in apartment buildings. At first, we evaluated the change of floor impact noise in the condition of with or without ceiling air-space. And then we installed perforated ceiling systems and glass wool at ceiling area. we expected that perforated ceiling systems could prevent air-spring effect in ceiling space. As a result, ceiling air space caused increasement of floor heavy impact noise about 2~4dB. But perforated ceiling & sound-absorbing materials system could give us reduction of heavy floor impact noise about 3dB. So this systems could be a good alternative to obey national regulations, because it can reduce heavy impact noise additional to floating floor systems.

  • PDF

A Study for Interior Noise Contribution of Support Material used in Railway Vehicle Floor (철도차량 부유상구조의 Floor support 재질이 차량 실내소음에 미치는 영향에 관한 연구)

  • Son, Byoung-Gu;Kim, Jong-Nyeun;Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1776-1781
    • /
    • 2008
  • To reduce interior noise of running vehicles, a floating floor construction has been widely used in recent railway industry. Among the key factors of the floating floor design, dynamic stiffness is of most important in acoustical point of view. Sometimes hard rubber type supports have often been selected due to the other design constraints such as heavy load condition, durability of rubber element and its cost etc., even though it seems like the softer support, the better isolation of noise and vibration. In this paper two representative floor supports have been considered to evaluate their effectiveness in interior noise contribution: one is a soft rubber and another is a relatively hard one. From the measured dynamic stiffness of the specimens, equivalent stiffness of actual floating floor has been derived to use in the analytical models. Calculated air-borne and structure-borne noise insulation properties of the floating floors have been compared with experiments in prototype car. In full car model interior noise levels of running vehicles have been predicted to quantify the effectiveness of the two different floating support materials and verified through the measured inside noise levels of actual train as well. By comparison with difference of running noise levels two materials for floor support can be investigated quantitatively so that it could be applied in floating floor design.

  • PDF