• Title/Summary/Keyword: floating bacteria

Search Result 29, Processing Time 0.103 seconds

Microbial Contamination in a Fresh-Cut Onion Processing Facility (신선편이 양파 가공작업장 내의 시설 및 공정별 미생물 오염 실태)

  • Lee, Hye-Ok;Kim, Ji-Young;Yoon, Doo-Hyun;Cha, Hwan-Soo;Kim, Gun-Hee;Kim, Byeong-Sam
    • Food Science and Preservation
    • /
    • v.16 no.4
    • /
    • pp.567-572
    • /
    • 2009
  • We evaluated the microbiological quality of a facility in which freshly cut onions were prepared. The total plate counts on walls, equipment, and raw materials were ND (not detected) to $10^1$ CFU/100 $cm^2$, $10^0{\sim}10^3$ CFU/100 $cm^2$, and $10^3{\sim}10^4$ CFU/g, respectively. No coliforms were detected on walls however, coliforms were detected at concentrations of ND to $10^3$ CFU/100 $cm^2$ and $10^3{\sim}10^4$ CFU/g on equipment and raw materials, respectively. The total plate counts for falling and floating bacteria in the processing plant were ND to $10^0$CFU/plate and $10^1{\sim}10^2$ $CFU/m^3$, respectively. Pathogenic microorganisms such as Escherichia coli, Salmonella spp, Staphylococcus aureus, and Listeria monocytogenes were not detected on walls, equipment, or raw materials. Overall, the results of the study indicate that hygiene control at the fresh-cut processing plant should be improved.

A Study on the Quality Improvement of Raw-Water Using Submerged Biofilter (생물막공정에 의한 상수원수의 수질개선에 관한 연구)

  • Lee, Soo-sik;Ahn, Seung-seop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.81-94
    • /
    • 1999
  • This study aims at a proposal of the plan that can improve raw water quality by an experimental study using influent water of Nak-dong river, which has been used as raw water for drinking in U-city, through the establishment of the submerged biofilter process PILOT PLANT of media packing channel method. From the analysis of removal efficiency for each water quality item of the collected sample, following results are obtained. First of all, the removal rate of suspended material, BOD, COD, T-N, TOC, turbidity, and $NH_3$ -N appear 82%, 78%, 42%, 15%, 57%, 43%, 54%, and 55% respectively and it is known that the submerged biofilter process of media packing channel method takes effects on water quality improvement from the above analysis results of water treatment efficiency. And the analyzed results for water temperature, residence time, and activities of microorganism, which can be the factors affect on water quality improvement, are as follows. 1) The removal rate variation of SS, BOD, and COD attendant on water temperature change is examined and it is known that the removal rate increases at $13^{\circ}C$ or above. 2) The removal rate of SS, BOD, and COD attendant on residence time is most active in the range of 0~18hr, 0~1.8hr, 0~2.7hr respectively, so it is found that the removal rate becomes smaller after 2.7hr. 3) From the examination of microorganism activity with the abundance of normal bacteria, it is found that the floating bacteria decrease as the flow distance from raw water inflow point of PILOT PLANT increases, and the adhesive bacteria have no concern with the flow distance. And it its known that the biomass of fine algae decreases as the flow distance from the raw water inflow point of PILOT PLANT increases from the examination with Chl-a.

  • PDF

Microbial Contamination in the Atmosphere in Seoul Metropolitan Area and its Control (서울지역에 있어서 거주공간의 미생물의 오염 및 이들에 대한 제어에 관하여)

  • 이배함;유관희;김영자;이복권;전영미;오재욱
    • Korean Journal of Microbiology
    • /
    • v.17 no.2
    • /
    • pp.65-71
    • /
    • 1979
  • On studying of microbes and appearance frequency which are floating around dwelling space and life environments in Seoul area, the results are summarized as follows ; 1. 1931 strains of 29 bacteria are isolated in dwelling spaces, Among them, there are Staphylococcus aureus, S. anthracis which are pathogenic to human beings. 2. In fungi, 76 strains of 13 species are isolated. That of highest frequency is confirmed to be Aspergillus which is pathogens of Aspergillosis (one of a group of diseases of animals and human being caused by various species of Aspergillus). The places, where the number of kinds and the frequency of appearances have been observed highest, are coffee shops, lunch counters and office rooms, while factory districts are of far lower level than expected. 3. 0.1% $HgCl_2$, Leasking oil, and Telephone disinfectant were better than any other in fungicidal effect.

  • PDF

Denitrification of Anaerobic Sludge in Hybrid type Anaerobic Reactor(I): Acetate as Substrate (Hybrid type 반응조에서의 혐기성 슬러지의 탈질(I): 초산을 기질로 사용한 경우)

  • Shin, Hang-Sik;Kim, Ku-Yong;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.35-44
    • /
    • 1999
  • In this study, it was attempted to remove nitrate and carbon in a single-stage reactor using acetate as substrate. Hybrid type upflow sludge baffled filter reactor was adopted using anaerobic sludge. Sludge bed in the bottom of reactor was intended to remove carbon and nitrate by denitrification and methanogenesis. And floating media in the upper part of reactor were intended to remove remaining carbon which was not removed due to the inhibition of nitrogen oxide on methane producing bacteria. The reactor removed over 96% of COD and most of nitrate with volumetric loading rate of $4.0kgCOD/m^3{\cdot}day$, hydraulic retention time of 24hr, 4,000mgCOD/L, and $266mgNO_3-N/L$. Nitrate in anaerobic sludge was converted to nitrogen gas(denitrification) or ammonia (ammonification) according to pH of influent, COD removal efficiency was easily affected by the change of volumetric loading rates and nitrate concentration. And when influent pH was about 4.7, most nitrate changed to ammonia while when influent pH was about 6.8~7.0, most nitrate denitrified independent of $COD/NO_3-N$ ratio. Most granules were gray and a few were black. In gray-colored granule, black inner side was covered with gray substance and SEM illustrated Methanoccoci type microorganisms which were compact spherical shape. Anaerobic filter removed residual COD effectively which was left in sludge bed due to the inhibition of nitrogen oxide.

  • PDF

UV Immune System of Personalized Space (개별공간의 자외선 살균 시스템)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.

An Experimental Study on the Air Sterilization Performance of A Reflective Electro Magnetic Energy System (Reflective Electro Magnetic Energy(REME)를 이용한 공기살균시스템의 성능평가에 관한 실험적 연구)

  • Hong, Jin Kwan;Lim, Ga Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.12
    • /
    • pp.509-514
    • /
    • 2016
  • From the point of view to prevent airborne infection-related diseases such as H1N1, SARS, and MERS, an actual application of air cleaning and purification systems including technologies like UVGI has become increasingly important. Recently, an air purification system using REME (Reflective Electro Magnetic Energy) developed in the U.S. is applied for indoor air purification and sterilization technology to counteract the outbreak of new airborne infections. In this study, an air sterilization performance experiment using REME was carried out. The results verified that air sterilization performance in the case of installing a REME system in a medical center was 31%, namely the number of floating bacteria decreased by 31% after only a five-day operation. In addition, the number of culture collections in the REME operating air conditioning systems using nonpathogenic Geobacillus stearothemophilus as a biological indicator decreased maximally to 67%. A field application of REME technology will be useful to prevent airborne infection-related diseases, especially in response to public health crises due to the advent of emerging diseases.

Speculation on the Identity of Bacteria Named TFOs Occurring in the Inefficient P-Removal Phase of a Biological Phosphorus Removal System

  • Lee, Young-Ok;Ahn, Chang-Hoon;Park, Jae-Kwang
    • Environmental Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • To better understand the ecology of tetrade forming organisms (TFOs) floating in a large amount of dairy wastewater treatment plant (WWTP) effluent (sequencing batch reactor [SBR]) during the inefficient phosphorus (P) removal process of an enhanced biological P removal system, the TFOs from the effluent of a full scale WWTP were separated and attempts made to culture the TFOs in presence/absence of oxygen. The intact TFOs only grew aerobically in the form of unicellular short-rods. Furthermore, to identify the intact TFOs and unicellular short-rods the DNAs of both were extracted, analyzed using their denaturing gradient gel electrophoresis (DGGE)-profiles and then sequenced. The TFOs and unicellular short-rods exhibited the same banding pattern in their DGGE-profiles, and those sequencing data resulted in their identification as Acinetobacter sp. The intact TFOs appeared in clumps and packages of tetrade cells, and were identified as Acinetobacter sp., which are known as strict aerobes and efficient P-removers. The thick layer of extracellular polymeric substance surrounding Acinetobacter sp. may inhibit phosphate uptake, and the cell morphology of TFOs might subsequently be connected with their survival strategy under the anaerobic regime of the SBR system.

Development of air-sterilization purification system of fusion and composite structure using broadband-to-active photocatalyst (광대역대 활성광촉매를 활용한 융·복합 구조 공기살균정화장치 개발)

  • Yoon, Sueng-Bae;Hwang, Yun-Jung;Kim, Seung-Cheon
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.147-151
    • /
    • 2019
  • Modern people spend most of their daily lives in their homes, schools, or workplaces, hospitals, shopping malls, subway stations, rooms, and parking lots. According to the survey, air quality management at the multi-use facility is less than 50% satisfied. In this study, a photocatalytic filtration system is developed by utilizing a broadband-to-active photocatalyst that utilizes a media photocatalyst filter that removes airborne germs from indoor air as well as indoor air quality and operates on visible light as well as ultraviolet light.

A Research to Decrease Airborne Microoganism the Train (전동차내 부유 미생물 저감방안에 관한 연구)

  • Choi, Sung-Ho;Choi, Soon-Gi;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2895-2901
    • /
    • 2011
  • SeoulMetro(line number 1 to 4) for the first half of the year. Therefore air quality in the subway is very important. It is passengers, such as sneezing and respiratory vital activities, Suspended due to skin keratin microbial action, and Microbial contaminants such as viruses. Hypersensitivity disorders, an atopic dermatitis, infectious diseases, allergic diseases, and can cause respiratory diseases. Ministry of Environment and National Institute of Environmental Research is managed so the life bacteria. It is emerging as the occupational health problems. Introduction of an appropriate ventilation system for cooling and dehumidification is needed. In line number 2, commuting and normal trains are measured in-room floating microbes. Suspended bacteria and fungi suspended in 2011 for 85 ~ 385$cfu/m^3$, 67 ~ 98$cfu/m^3$ is lower than baseline. Suspended to prevent microbial contamination and air conditioning equipment performance is a substantial improvement. Suspended micro-organisms and the impact on passenger room ventilation is increased. Electric car how to improve air quality substantially investigated.

  • PDF

Influence of denitrified biofloc water on the survival rate and physiological characteristics of Pacific white shrimp juveniles, Litopenaeus vannamei (바이오플락 탈질수가 어린 흰다리새우, Litopenaeus vannamei의 생존율 및 생리특성에 미치는 영향)

  • Kim, Su-Kyoung;Jang, Jin Woo;Jo, Yong Rok;Kim, Jun-Hwan;Kim, Su Kyoung
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.2
    • /
    • pp.136-143
    • /
    • 2019
  • This study investigates the effect of denitrified biofloc water on changes in the water quality parameters and the physiological characteristics of shrimps. Biofloc rearing water contains a large number of microorganisms and can rapidly stabilize the water quality and energy saving if reusable due to high water temperatures. Rearing water contain floating bacteria with both aerobic and anaerobic bacteria. Therefore, when the carbon source is added in limited air supply, the anaerobic state is activated and the denitrification process is possible. In this study, the denitrification water had the following properties: ammonia (6.9 mg L-1), nitrite (0.3 mg L-1), nitrate concentration (9.2 mg L-1), high pH (8.42) and alkalinity (590 mg L-1). The experimental group consisted of seawater (SW, control), a mixture of Seawater and denitrified biofloc water (DNW) in the ratio of 3:1, 1:1 and DNW only. All experiments were done in triplicate. As a result, the survival rate never changed even when 100% of the denitrification water was utilized. However, a body fluid analysis showed that creatine and BUN were increased due to index of stress and the tissue damage resulting from the high denitrified water content. Body fluid ions (Na+, K+, and Cl-) significantly decreased as the denitrified water content increased. It was recommended that the denitrification water be mixed with a certain ratio (less than 50%) in the future as it may affect the osmotic pressure control in shrimps.