• 제목/요약/키워드: flexure yielding

검색결과 28건 처리시간 0.024초

Applicability of Cu-Al-Mn shape memory alloy bars to retrofitting of historical masonry constructions

  • Shrestha, Kshitij C.;Araki, Yoshikazu;Nagae, Takuya;Omori, Toshihiro;Sutou, Yuji;Kainuma, Ryosuke;Ishida, Kiyohito
    • Earthquakes and Structures
    • /
    • 제2권3호
    • /
    • pp.233-256
    • /
    • 2011
  • This paper investigates the applicability of newly developed Cu-Al-Mn shape memory alloy (SMA) bars to retrofitting of historical masonry constructions by performing quasi-static tests of half-scale brick walls subjected to cyclic out-of-plane flexure. Problems associated with conventional steel reinforcing bars lie in pinching, or degradation of stiffness and strength under cyclic loading, and in their inability to restrain residual deformations in structures during and after intense earthquakes. This paper attempts to resolve the problems by applying newly developed Cu-Al-Mn SMA bars, characterized by large recovery strain, low material cost, and high machinability, as partial replacements for steel bars. Three types of brick wall specimens, unreinforced, steel reinforced, and SMA reinforced specimens are prepared. The specimens are subjected to quasi-static cyclic loading up to rotation angle enough to cause yielding of reinforcing bars. Corresponding nonlinear finite element models are developed to simulate the experimental observations. It was found from the experimental and numerical results that both the steel reinforced and SMA reinforced specimens showed substantial increment in strength and ductility as compared to the unreinforced specimen. The steel reinforced specimen showed pinching and significant residual elongation in reinforcing bars while the SMA reinforced specimen did not. Both the experimental and numerical observations demonstrate the superiority of Cu-Al-Mn SMA bars to conventional steel reinforcing bars in retrofitting historical masonry constructions.

나선철근으로 횡구속된 정사각형 RC 기둥의 내진성능 (Seismic Performance of Square RC Column Confined with Spirals)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권5호
    • /
    • pp.88-97
    • /
    • 2012
  • 본 연구에서는 비내진 교각의 내진성능과 휨-전단 거동을 파악하고자 형상비 4.5인 정사각형의 중실 및 중공단면 철근콘크리트 교각실험체를 제작하여 일정한 축력하에서 변위비 등급을 증가시켜 가면서 횡하중을 가력하는 실험을 수행하였다. 본 연구는 철근콘크리트 교각의 한정연성 내진설계를 위한 실험적 기초자료의 제공과 함께 성능단계별 교각성능 및 손상평가를 위한 정량적 수치와 경향을 제공하기 위한 것이며, 파괴거동, 극한변위, 극한드리프트비율, 변위연성도, 응답수정계수, 등가점성감쇠비, 잔류변형지수, 유효강성, 철근 변형률 등의 주요 내진성능 인자들에 대한 분석결과와 비선형 해석 결과를 나타내었다.

비선형 지진 해석을 위한 보-기둥 요소 (Beam-Column Element Applicable to Nonlinear Seismic Analysis)

  • 김기동;고만기;이상수
    • 한국강구조학회 논문집
    • /
    • 제9권4호통권33호
    • /
    • pp.557-578
    • /
    • 1997
  • 이 연구의 목적은 매우 큰 지진하에 휨 모멘트에 의해서만 항복하는 부재와 휨 모멘트와 축 방향력에 의하여 항복하는 부재를 모델 할 수 있는 보-기둥 요소를 개발하는데 있다. 이 요소는 직렬 힌지 모델 (one-component series hinge model)로 간주 될 수 있으며, 축 방향 강성도 변화와 축 방향 소성 변형을 고려 할 수 있고 또한 단조, 주기, 임의 하중 등을 적절히 모델 할 수 있는 경화 법칙 (hardening rules)을 고려한다. 일반적으로 이 요소는 실험 결과 및 화이버 모델 (fiber model)에 비교하여 볼 때 기존의 이직선 힌지 모델 (bilinear hinge model)보다 우수한 거동을 보였고 모멘트 저항 뼈대 구조물의 강 부재의 보-기둥 거동을 적절하게 모델 할 수 있었다. 개발된 보-기둥 요소는 지진 하중하에서 구조물의 전체적인 거동과 설계에 필요한 국부 변형량을 기존의 이직선 힌지 모델 보다 매우 정확하게 예측 할 수 있다.

  • PDF

휨 항복형 철근콘크리트 전단벽의 등가소성힌지길이 모델 (Equivalent Plastic Hinge Length Model for Flexure-Governed RC Shear Walls)

  • 문주현;양근혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.1-8
    • /
    • 2014
  • 본 연구의 목적은 경계요소를 갖는 철근콘크리트 전단벽의 잠재소성힌지길이를 합리적으로 평가할 수 있는 단순모델의 제시이다. 전단벽의 높이에 따른 이상화된 곡률분포로부터, 기본방정식은 항복모멘트와 최대모멘트 그리고 사인장균열에 의한 부가모멘트의 함수로 일반화되었다. 전단벽의 항복모멘트와 최대모멘트는 변형률 적합조건과 힘의 평형조건을 기반하여 산정하였다. 사인장균열 발생의 여부는 ACI 318-11에서 제시된 콘크리트의 전단력으로부터 검토되었으며, 부가모멘트는 Park and Paulay에 의해 제시된 트러스기구를 이용하여 산정하였다. 이들 모멘트식들은 다양한 변수범위에서 변수연구를 수행하였다. 결과적으로 등가소성힌지길이는 주철근 및 수직철근지수와 축력지수의 함수로 제시될 수 있었다. 제시된 등가소성힌지길이의 모델은 실험결과의 비교에서 평균 및 표준편차가 각각 1.019와 0.102로 실험 결과를 정확하게 예측하였다.

휨을 받는 압축강도 80 MPa 수준의 고강도 콘크리트 부재의 구조거동 실험 연구 (An Experimental Study on Structural Behavior of High-strength Concrete Members with Compressive Strength of 80 MPa Subjected to Flexure)

  • 양인환;황철성;김경철;조창빈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권4호
    • /
    • pp.1-12
    • /
    • 2017
  • 본 연구에서는 휨을 받는 압축강도 80 MPa 수준의 고강도 콘크리트 부재의 구조거동 실험 연구를 수행하였다. 실험변수는 보통(SD 400) 및 고강도(SD 600)철근, 0.98~1.58%의 종방향 철근비, $200{\times}250$, $200{\times}300mm$의 단면크기를 고려하였다. 9개의 보 부재를 제작하여 휨 실험을 수행하였으며 극한휨강도, 하중-처짐 관계, 균열 형태, 파괴형상 및 연성을 파악하였다. 실험결과는 철근비가 증가함에 따라 휨강도는 증가하고 연성은 감소한다. 또한, 철근비가 증가함에 따라 균열의 개수가 증가하며 균열폭은 감소하는 경향을 나타내었다. 철근의 강도 등급에 따른 하중-균열폭 관계는 뚜렷한 차이를 나타내지 않는다. 콘크리트 비선형거동 해석을 수행하였으며, 극한하중 예측값과 측정값을 비교하였다. 고강도 콘크리트의 휨거동 예측 결과는 실험부재의 휨강도를 전반적으로 과소평가하고 있다.

철근(鐵筋)콘크리트 평면(平面)뼈대구조물(構造物)의 비선형해석(非線型解析) (Nonlinear Analysis of Planar Reinforced Concrete Frames)

  • 강영진
    • 대한토목학회논문집
    • /
    • 제3권4호
    • /
    • pp.149-155
    • /
    • 1983
  • 유한요소법(有限要素法)에 의한 철근(鐵筋)콘크리트 평면(平面)뼈대구조물(構造物)의 비선형수치해석법(非線型數値解析法)을 제시(提示)하였다. 콘크리트의 구열(龜裂), 철근(鐵筋)의 강복등(降伏等) 재료상(材料上)의 비선형성(非線型性)을 고려(考慮)하였다. 이 방법(方法)에 의하면 휨에 의해 파괴(破壞)되는 철근(鐵筋)콘크리트 평면(平面)뼈대구조물(構造物)의 사용하중(使用荷重) 및 극한하중(極限荷重) 영역(領域)을 통(通)한 응답(應答)에 대한 정확(正確)한 수치해(數値解)를 얻을 수 있다. 이 방법(方法)의 정확성(正確性)과 유용성(有用性)을 입증(立證)하기 위해 수치해석예(數値解析例)를 제시(提示)하고 이를 실험결과(實驗結果)와 다른 연구(硏究)에 의한 해석결과(解析結果)와 비교(比較)하였다.

  • PDF

Structural Steel as Boundary Elements in Ductile Concrete Walls

  • Cho, Soon-Ho
    • KCI Concrete Journal
    • /
    • 제12권2호
    • /
    • pp.73-84
    • /
    • 2000
  • A new form of construction utilizing structural steel as the boundary elements in ductile flexural concrete walls is proposed to solve the bar congestion problems in such a heavily reinforced region, while maintaining the ductility and energy absorption capacity comparable to their traditional form. Two wall specimens containing rectangular hollow structural sections (HSS) and channels at their ends respectively, and one companion standard reinforced concrete wall specimen with concentrated end reinforcement were constructed and tested under reversed cyclic loading to evaluate the construction process as well as the structural performance. Initially, all three specimens were chosen and detailed with some caution to have approximately the same flexural capacity without change of the original shape and dimension of a rectangular cross section correction. Analysis and comparison of test results indicated that the reversed cyclic responses of three walls showed similar hysteretic properties, but in those with steel boundaries, local buckling of the corresponding steel webs and flanges following significant yielding was a dominant factor to determine the hysteretic response. The monotonic and cyclic responses predicted based on a sectional approach was also presented and found to be in good agreement with measured results. Design recommendations considering local instability of the structural steel elements and the interaction between steel chords and a concrete web member in such a composite wall are presented.

  • PDF

Design and behaviour of double skin composite beams with novel enhanced C-channels

  • Yan, Jia-Bao;Guan, Huining;Wang, Tao
    • Steel and Composite Structures
    • /
    • 제37권5호
    • /
    • pp.517-532
    • /
    • 2020
  • This paper firstly developed a new type of Double Skin Composite (DSC) beams using novel enhanced C-channels (ECs). The shear behaviour of novel ECs was firstly studied through two push-out tests. Eleven full-scale DSC beams with ECs (DSCB-ECs) were tested under four-point loading to study their ultimate strength behaviours, and the studied parameters were thickness of steel faceplate, spacing of ECs, shear span, and strength of concrete core. Test results showed that all the DSCB-ECs failed in flexure-governed mode, which confirmed the effective bonding of ECs. The working mechanisms of DSCB-ECs with different parameters were reported, analysed and discussed. The load-deflection (or strain) behaviour of DSCB-ECs were also detailed reported. The effects of studied parameters on ultimate strength behaviour of DSCB-ECs have been discussed and analysed. Including the experimental studies, this paper also developed theoretical models to predict the initial stiffness, elastic stiffness, cracking, yielding, and ultimate loads of DSCB-ECs. Validations of predictions against 11 test results proved the reasonable estimations of the developed theoretical models on those stiffness and strength indexes. Finally, conclusions were given based on these tests and analysis.

Crack mapping in RC members using distributed coaxial cable crack sensors: modeling and application

  • Greene, Gary Jr.;Belarbi, Abdeldjelil;Chen, Genda
    • Smart Structures and Systems
    • /
    • 제1권4호
    • /
    • pp.385-404
    • /
    • 2005
  • The paper presents a model to calculate reinforcement strain using measured crack width in members under applied tension, flexure, and/or shear stress. Crack mapping using a new type of distributed coaxial cable sensors for health monitoring of large-scale civil engineering infrastructure was recently proposed and developed by the authors. This paper shows the results and performance of such sensors mounted on near surface of two flexural beams and a large scale reinforced concrete box girder that was subjected to cyclic combined shear and torsion. The main objectives of this health monitoring study was to correlate the sensor's response to strain in the member, and show that magnitude of the signal's reflection coefficient is related to increases in applied load, repeated cycles, cracking, and reinforcement yielding. The effect of multiple adjacent cracks, and signal loss was also investigated. The results shown in this paper are an important step in using the sensors for crack mapping and determining reinforcement strain for in-situ structures.

연성을 고려한 철근콘크리트 기둥의 강도감소계수 적용에 관한 연구 (An Application of Strength Reduction Factors to Reinforced Concrete Columns considering Ductility)

  • 손혁수;이재훈
    • 콘크리트학회논문집
    • /
    • 제11권4호
    • /
    • pp.147-156
    • /
    • 1999
  • Current design code states that the strength reduction factor shall be permitted to be increased linearly from that for axial compression to that for flexure as the design axial load strength $\Phi$cPn decrease from 0.1fckAg to zero. Since this empirically adopted axial load level of $\Phi$cPn=0.1fckAg considers only sectional area and concrete strength, the other variables such as steel ratio, steel yielding strength, and steel arrangement can not be considered. This research is performed to investigate the consistency and the rationality of the code requirement for determination of column design strength. A nonlinear axial force-moment-curvature analysis was conducted in order to investigate the ductility of reinforced concrete column sections. As the result of ductility analysis, it was found that the ductility at the axial force of $\Phi$cPn=0.1fckAg represented a lock of consistency for the various variable contained sections. Therefore, a more reasonable application method of strength reduction factor is proposed, that is based on the strain ductility index.