• 제목/요약/키워드: flexural strength

검색결과 3,313건 처리시간 0.038초

THE EFFECT OF SURFACE FINISHES ON FLEXURAL STRENGTH, FRACTURE TOUGHNESS OF FELDSPATHIC DENTAL PORCELAIN

  • Chang, Il-Sung;Lee, Sun-Hyung;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.293-305
    • /
    • 2005
  • Statement of problems. Conventional feldspathic porcelain is used extensively as a restorative material and it is subjected to grinding and polishing during fabrication and delivery procedures. There is still considerable controversy concerning the best methods to achieve the strongest porcelain restorations after such adjustments. Purpose. The objective of this study was to investigate the effects of (1) overglazing, (2) selfglazing, and (3) fine polishing on the flexural strength and fracture toughness of feldspathic dental porcelain. Material and method. Ninety porcelain disks were prepared for flexural strength test and sixty porcelain disks were fabricated for fracture toughness test. Specimens were divided into three groups for each test as follows: 1) overglazed 2) self-glazed 3) polished. The flexural strength of feldspathic porcelains was determined by ring-on-ring biaxial flexural strength test. The fracture toughness values of three experimental groups were obtained by indentation fracture toughness test. Results. The flexural strength of overglazed group was significantly higher than that of selfglazed and polished group (P<0.05), while the difference between self-glazed and polished group was not significant (P>0.05). The fracture toughness values of overglazed and polished group were significantly higher than that of self-glazed group (P<0.05), while the difference between overglazed and polished group was not significant (P>0.05). Conclusions. This results supported the use of polishing as an alternative to glazing metal ceramic restorations, as it was not detrimental in flexural strength and fracture toughness. But, under the conditions of this study, overglazing was the ideal surface finishing method of feldspathic dental porcelain.

의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구 (DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING)

  • 최훈달;권긍록;김형섭;최대균
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.

A COMPARATIVE STUDY BETWEEN DEGREE OF CONVERSION AND FLEXURAL STRENGTH OF COMPOSITE RESINS

  • Lee Seong-Hee;Pae Ahran;Kim Sung-Hun
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.333-342
    • /
    • 2006
  • Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal information in the literature attempting to compare degree of conversion, flexural strength and their correlation between restorative composite resins and flowable composite resins. Purpose. The purposes of this study were to measure the degree of conversion and flexural strength of composite resins with different rheological behavior and to correlate the two properties. Materials and methods. Four restorative (Vit-1-escence, Z-250, Tetric ceram, Esthet-X) and four flowable (Aeliteflo, Admiraflow, Permaflo, Revolution) light-curing composite resins were investigated. The degree of conversion(DC) was analyzed with Fourier transfer infra-red spectroscopy(FTIR) spectrum by a potassium bromide(KBr) pellet transmission method. The spectrum of the unpolymerized specimen had been measured before the specimen was irradiated for 60s with a visible light curing unit. The Poiymerized specimen was scanned for its in spectrum. The flexural strength(FS) was measured with 3-point bending test according to ISO 4049 after storage in water at $37^{\circ}C$ for 24 hours. The data were statistically analyzed by an independent sample t-test and one-way ANOVA at the significance level of 0.05. The dependence of flexural strength on the degree of conversion was also analyzed by regression analysis. Results. Mean DC and FS values ranged from 43% to 61% and from 84.7MPa to 156.7MPa respectively. DC values of the flowable composite resins were significantly higher than those of restorative composite resins (P < 0.05). The FS values of restorative composite resins were greater than those of flowable composite resins. No statistically significant correlation was observed between the DC and the FS tested in any of the composites. The dependence of FS on DC in restorative or flowable composite resins was not significant. Conclusion. It can be concluded that radical polymerization of the organic matrix is not a major factor in determining flexural strength of the commercially available composite resins.

Flexural strength and microstructure of two lithium disilicate glass ceramics for CAD/CAM restoration in the dental clinic

  • Kang, Suk-Ho;Chang, Juhea;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.134-140
    • /
    • 2013
  • Objectives: There has been a growing interest in glass ceramic systems with good esthetics, high fracture resistance and bonding durability, and simplified fabrication techniques using CAD/CAM. The aim of this study is to compare flexural strength before and after heat treatment of two lithium disilicate CAD/CAM blocks, IPS e.max CAD (Ivoclar Vivadent) and Rosetta SM (Hass), and to observe their crystalline structures. Materials and Methods: Biaxial flexural strength was tested according to ISO 6872 with 20 disc form specimens sliced from each block before and after heat treatment. Also, the crystalline structures were observed using field-emission scanning microscopy (FE-SEM, Hitachi) and x-ray diffraction (XRD, Rigaku) analysis. The mean values of the biaxial flexural strength were analyzed by the Mann-Whitney U test at a significance level of p = 0.05. Results: There were no statistically significant differences in flexural strength between IPS e.max CAD and Rosetta SM either before heat treatment or after heat treatment. For both ceramics, the initial flexural strength greatly increased after heat treatment, with significant differences (p < 0.05). The FE-SEM images presented similar patterns of crystalline structure in the two ceramics. In the XRD analysis, they also had similar patterns, presenting high peak positions corresponding to the standard lithium metasilicate and lithium disilicate at each stage of heat treatment. Conclusions: IPS e.max CAD and Rosetta SM showed no significant differences in flexural strength. They had a similar crystalline pattern and molecular composition.

표면연마와 제작방법에 따른 임시 수복용 레진의 굽힘강도에 관한 비교 연구 (Comparative study of flexural strength of temporary restorative resin according to surface polishing and fabrication methods)

  • 임재훈;이재인
    • 구강회복응용과학지
    • /
    • 제37권1호
    • /
    • pp.16-22
    • /
    • 2021
  • 목적: 표면연마와 제작방법이 임시 수복용 레진의 굽힘강도에 미치는 영향을 분석하고자 한다. 연구 재료 및 방법: 4가지 제작방법을 이용하여 각각 30개의 임시 수복용 레진 시편을 제작하였고, 기계적 연마로 표면연마를 시행한 그룹과 연마를 시행하지 않은 2개의 그룹으로 나누었다. 시편은 37℃ 항온기에 24시간 보관 후 만능시험기(Universal testing machine)을 이용하여 3점 굽힘강도를 측정하였다. 통계분석은 Two-way ANOVA와 Tukey's HSD test, Paired t-test를 이용하여 분석하였다. 결과: 표면연마 여부와 관계없이 CAD/CAM milling으로 제작한 시편이 가장 높은 굽힘강도를 나타냈고, SLA 3D printing, DLP 3D printing, Conventional method 순으로 높은 굽힘강도를 나타냈다. 결론: 표면연마는 임시 수복용 레진의 굽힘강도에 유의한 영향을 끼치지 못했지만(P > 0.05), 제작방법에 의해서는 굽힘강도의 유의한 차이가 나타났다(P < 0.05).

탄소보강근의 제조 조건에 따른 휨강도와 기공 특성과의 상관성 분석 (Analysis of Correlation between Flexural Strength and Pore Characteristics on CFRP Rebar as Fabrication Method)

  • 김남일;권도영;추용식
    • Composites Research
    • /
    • 제35권5호
    • /
    • pp.328-333
    • /
    • 2022
  • 본 연구에서는 CFRP rebar의 휨강도와 기공 특성과의 상관성을 도출하기 위해 CFRP rebar의 제조 조건을 제어하였다. 이때 CFRP rebar의 제조 조건은 리브 유무, 수지 온도 및 경화로 온도 등을 조정하였으며, 제조된 CFRP rebar의 휨강도와 기공특성을 분석하였다. CFRP rebar의 휨강도는 리브 유무, 경화로 온도 및 수지 온도 등, 제조 조건에 따라 변화되었다. 특히 리브가 감겨지지 않은 경우, CFRP rebar의 휨강도 값이 크게 낮아진다는 것도 확인하였다. Nano X-Ray CT 분석 결과, 수지 온도가 60℃인 CFRP rebar에서 최대 기공 지름을 나타내었다. 광학현미경 분석 결과, 최대 기공율은 No. 1에서 6.89%, 최소 기공율은 No. 7의 2.88%이었다. 광학현미경을 통한 기공율과 휨강도의 상관관계계수는 -0.64이었으며, 이는 Nano X-Ray CT 기공율 및 기공크기와의 상관관계계수 보다 높은 값이었다.

균열 보수용 폴리머 시멘트 복합체의 휨접착강도에 관한 연구 (Exploring the Flexural Bond Strength of Polymer-Cement Composition in Crack Repair Applications)

  • 조영국
    • 한국건축시공학회지
    • /
    • 제24권1호
    • /
    • pp.23-34
    • /
    • 2024
  • 본 연구의 목적은 RC 구조물의 균열 보수용 폴리머 시멘트 복합체의 휨접착성능을 평가하기 위함이다. 시멘트 모르타르에 다양한 크기의 균열을 만들어 PCCs를 충전한 후, 소정의 양생을 거쳐 휨접착강도와 휨강도 개선 정도를 파악하였다. 연구결과, 균열보수용 PCCs의 휨접착강도는 시멘트의 종류, 폴리머 종류 및 폴리머 결합재비에 따라 영향을 받으며 실리카퓸을 혼입한 초조강시멘트를 사용한 경우가 보통시멘트를 사용한 경우에 비해 최대 19.0%의 휨접착강도 개선효과가 나타났다. PCCs로 충전된 시멘트 모르타르의 휨강도 개선 정도는 균열폭의 영향보다는 균열깊이에 따라 큰 차이를 보였으며 균열에 충전된 PCCs가 단순히 보수재료로서 기능뿐만 아니라 어느 정도 휨강도를 개선시키는 보강재료로서도 역할을 하였다. 본 연구결과, 초조강시멘트, 3종류의 폴리머 디스퍼전과 실리카퓸, 60%~80%의 높은 폴리머 결합재비로 제작한 PCCs가 균열을 충전하는 보수재료로서 현장에서 충분히 사용될 수 있을 것이다.

Seismic behavior of high-strength concrete flexural walls with boundary elements

  • Kim, Seung-Hun;Lee, Ae-Bock;Han, Byung-Chan;Ha, Sang-Su;Yun, Hyun-Do
    • Structural Engineering and Mechanics
    • /
    • 제18권4호
    • /
    • pp.493-516
    • /
    • 2004
  • This paper addresses the behavior and strength of structural walls with a concrete compressive strength exceeding 69 MPa. This information also enhances the current database for improvement of design recommendations. The objectives of this investigation are to study the effect of axial-load ratio on seismic behavior of high-strength concrete flexural walls. An analysis has been carried out in order to assess the contribution of deformation components, i.e., flexural, diagonal shear, and sliding shear on total displacement. The results from the analysis are then utilized to evaluate the prevailing inelastic deformation mode in each of wall. Moment-curvature characteristics, ductility and damage index are quantified and discussed in relation with axial stress levels. Experimental results show that axial-load ratio have a significant effect on the flexural strength, failure mode, deformation characteristics and ductility of high-strength concrete structural walls.

포스트텐셔닝 공법의 프리트스레스트 고강도 빔부재의 균열 및 극한 거동 (An Cracking and Ultimate Behavior of Post-tensioned Prestressed High Strength Concrete Beams)

  • 이성철;최영철;오병환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.323-326
    • /
    • 2005
  • Although many structures. with high strength concrete have been recently constructed, the flexural behavior of reinforced and prestressed concrete beams with high strength concrete is not exactly defined. This paper presents an experimental study on the flexural strength of the high strength concrete beams. Five large scale beams simply supported were tested and measured. Each beam was loaded by two symmetrical concentrated loads applied at 1.25m from the center of span. The concrete strength, the prestressed force and longitudinal tensile reinforcement ratio vary from beam to beam. From the experimental tests, the flexural strength from tests is larger than the nominal flexural strength of codes. Moreover, the initial crack-load is affected by the prestressed force and the crack width and spacing are controlled by the longitudinal tensile reinforcement ratio.

  • PDF

Evaluation of polymethyl methacrylate resin mechanical properties with incorporated halloysite nanotubes

  • Abdallah, Reham M.
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.167-171
    • /
    • 2016
  • PURPOSE. This study inspects the effect of incorporating halloysite nanotubes (HNTs) into polymethyl methacrylate (PMMA) resin on its flexural strength, hardness, and Young's modulus. MATERIALS AND METHODS. Four groups of acrylic resin powder were prepared. One group without HNTs was used as a control group and the other three groups contained 0.3, 0.6 and 0.9 wt% HNTs. For each one, flexural strength, Young's modulus and hardness values were measured. One-way ANOVA and Tukey's test were used for comparison (P<.05). RESULTS. At lower concentration (0.3 wt%) of HNT, there was a significant increase of hardness values but no significant increase in both flexural strength and Young's modulus values of PMMA resin. In contrast, at higher concentration (0.6 and 0.9 wt%), there was a significant decrease in hardness values but no significant decrease in flexural strength and Young's modulus values compared to those of the control group. CONCLUSION. Addition of lower concentration of halloysite nanotubes to denture base materials could improve some of their mechanical properties. Improving the mechanical properties of acrylic resin base material could increase the patient satisfaction.