• Title/Summary/Keyword: flexural failure

Search Result 861, Processing Time 0.025 seconds

Flexural Tests on Post-Tensioned Segmental Composite Beam (세그멘탈 합성보의 휨 실험)

  • 김인규;설동재;유승룡
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.487-492
    • /
    • 2002
  • The interior portion of Gerber's beam are constructed with post-tensioned segmental composite beams in this study. A precast concrete member which is larger than the limits of domestic transportation regulation in weight, length, and volume is divided into three parts, transported separately, and erected with a composite member by post-tensioning in site. Static flexural loading tests are performed on Gerber's type frames which are consisted with 2.5m overhangs and 5m interior beams composited from three pieces. The connection of overhang to interior composite beam and beam to beam, and flexural performance of interior portion of Gerber's beam are examined thoroughly. All of the tests are ended with a compression failure of the interior composite beams over the design strength of homogeneous beams. The brittle connection failures or tensile failures with the failure of lower strand was not observed in any test frames.

  • PDF

A Nonlinear Finite Element Analysis to Study the Flexural Behavior of Reinforced Concrete Walls (철근콘크리트 벽체의 휨거동에 관한 비선형 유한요소해석)

  • Han Min Ki;Park Wan Shin;Han Byung Chan;Hwang Sun Kyoung;Choi Chang Sik;Yun Hyun Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.520-523
    • /
    • 2004
  • The finite element method(FEM) models were developed for the reinforced concrete flexural walls and analysed under constant axial and monotonic lateral load using ABAQUS. The major objective of the present study is to determine if the ABAQUS finite element program can be used to accurately model the post-cracked mode of failure in plastic regions of walls, and, if so, to develop practical failure criteria in the plastic range of the material response. The research comprises constitutive models to represent behavior of the materials that compose a wall on the basis of experimental data, development of techniques that are appropriate for analysis of reinforced concrete structures, verification, and calibration of the global model for reinforced concrete walls of increasing complexity. Results from the analyses of these FEM models offers significant insight into the flexural behavior of benchmark data.

  • PDF

Analytical Study of Reinforced Concrete Beams Strengthened with Fiber Reinforced Plastic Laminates (적층판으로 보강된 철근콘크리트보에 대한 해석적 연구)

  • Chae, Seoung-Hun;Kang, Joo-Won
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.05a
    • /
    • pp.206-211
    • /
    • 2004
  • This paper deals with the flexural strengthening of reinforced concrete beams by means of thin fiber reinforced plastic(FRP) laminas. This study focuses on modeling of structural of concrete bonded FRP laminate in flexural bending members. Used computational equation is derived by relation of stress and strain. The section analysis is based on experimental observations of a linear strain distribution in the cross section until failure, and a multi-linear moment-deflection curve that is divided into four regions, each terminated by a similarly numbered point. The load-deflection relationship in each region is assumed to be linear. The present model is validated to compare wit the experiment of 4-point bending tests of R/C rectangular beams strengthened with CFRP laminates, and has well predicted the moment-displacement relationships of members.

  • PDF

Structural Performance of Flexural Members Enlarged with Epoxy Mortar System at Soffit (변형에폭시계 재료를 사용한 하부증대 보의 구조적 성능)

  • 홍건호;조하나;신영수;정혜교
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.833-838
    • /
    • 1998
  • This paper is aimed to investigate structural performance of flexural members enlarged with epoxy mortar at soffit. Main test variables are steel ratio and interface treatment method and six test beams are tested to investigate the effect of each test variables on maximum load capacity, load-deflection and moment-curvature relationship, interface behavior and failure mode. Test results show that section enlarged beams can carry almost same load of the monolithic beams with same size and the flexural stiffness and cracking moments are increased about 2.5 times and 50 to 70%of failure moment in comparison with same sized control beam, respectively. However, deflections and curvatures are decreased at the same load and interface fractures are not discovered at the ultimate load.

  • PDF

Analysis of Local Failure Machanism of Fiber Reinforced Concrete by Impact of High-Velocity Projectile (고속비상체 충돌에 대한 섬유보강 콘크리트의 국부파괴 매커니즘 분석)

  • Han, Sang-Hyu;Kim, Gyu-Yong;Kim, Hong-Seop;Lee, Bo-Kyeong;Kim, Jung-Hyun;Kim, Rae-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.28-29
    • /
    • 2014
  • In this study, flexural strength by fiber reinforced for steel fiber and reinforced polyamide fiber concrete, and concrete fracture properties by improvement of flexural toughness and high-velocity projectile impact were evaluated. As a result, it was confirmed that flexural strength are improved by distribution of stress and suppress of cracks, and the back desquamation of concrete by high-velocity projectile impact is suppressed. In addition, It was observed that the spalling of rear is caused when tension stress is caused as shock wave by high-velocity projectile impact was transferred to the rear and tension stress is suppressed by fiber reinforcement.

  • PDF

Effect of Silicon Nitride Whisker Content on the Flexural Strength of Silicon Nitride-Boron Nitride-Silicon Carbide Multi-Layer Composites

  • Park, Dong-Soo;Cho, Byung-Wook
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.9
    • /
    • pp.832-836
    • /
    • 2003
  • Multi-layer ceramic composites were prepared by tape casting followed by hot pressing using silicon nitride layer with silicon nitride whiskers, silicon nitride layer with silicon carbide particles and boron nitride-alumina layer. The whiskers were aligned during the casting. As the whisker content of the silicon nitride layer was increased up to 10 wt%, the flexural strength of the multi-layer composite was increased. However, further increase of the whisker content in the layer resulted in a rapid decrease of the strength of the composite. The results suggest that the strength of multi-layer ceramic composite showing non-catastrophic failure behavior can be significantly improved by incorporating the aligned whiskers in the layers.

Experimental and analytical assessment of SRF and aramid composites in retrofitting RC columns

  • Dang, Hoang V.;Shin, Myoungsu;Han, Sang Whan;Lee, Kihak
    • Earthquakes and Structures
    • /
    • v.7 no.5
    • /
    • pp.797-815
    • /
    • 2014
  • This research aimed to investigate retrofitting methods for damaged RC columns with SRF (Super Reinforced with Flexibility) and aramid composites and their impacts on the seismic responses. In the first stage, two original (undamaged) column specimens, designed to have a flexural- or shear-controlled failure mechanism, were tested under quasi-static lateral cyclic and constant axial loads to failure. Afterwards, the damaged column specimens were retrofitted, utilizing SRF composites and aramid rods for the flexural-controlled specimen and only SRF composites for the shear-controlled specimen. In the second stage, the retrofitted column specimens were tested again under the same conditions as the first stage. The hysteretic responses such as strength, ductility and energy dissipation were discussed and compared to clarify the specific effects of each retrofitting material on the seismic performances. Generally, SRF composites contributed greatly to the ductility of the specimens, especially for the shear-controlled specimen before retrofitting, in which twice the deformation capacity was obtained in the retrofitted specimen. The shear-controlled specimen also experienced a flexural failure mechanism after retrofitting. In addition, aramid rods moderately fortified the specimen in terms of the maximum shear strength. The maximum strength of the aramid-retrofitted specimen was 12% higher than the specimen without aramid rods. In addition, an analytical modeling of the undamaged specimens was conducted using Response-2000 and Zeus Nonlinear in order to further validate the experimental results.

Flexural Strengthening Characteristic of Sleeper Member Traditional Wooden Architecture (전통 목구조 멍에 부재의 휨 보강 특성)

  • Kim, Jeong-Sup;Cho, Cheol-Hee;Shin, Young-Seok;Cho, Youn-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • This study investigates experimentally flexural behavior and CFB(Carbon Fiber Bar) reinforcing effects of timber sleeper in traditional storied tower house. As a test result, standard sleepers without CFB(Carbon Fiber Bar) reinforcement show flexural cracks at the bottom member at the beginning of loading stage and leads to fracture. However, reinforced specimens with CFB show initial shrinkage at the upper part of specimen by compression, instead of flexural cracks at the bottom, and finally show compressive failure or fracture after failure of CFB and it proves that reinforcing effects by CFB are exerted from early loading. Reinforced specimens showed higher strength in yield strength by 6%~38%, and ultimate strength by 8%~17%, than those of standard specimens. Reinforced specimen is considered that specimen with flexural reinforcement using CFB can expect flexural deflection control effect. Reinforced specimen shows higher ductile coefficient increase of average 141% compared than standard specimens and it proves that higher structural ductile behavior can be expected in reinforced specimens.

Experimental assessment on flexural behavior of demountable steel-UHPC composite slabs with a novel NPR steel plate

  • Jin-Ben Gu;Jun-Yan Wang;Yi Tao;Qing-Xuan Shi
    • Steel and Composite Structures
    • /
    • v.49 no.4
    • /
    • pp.381-392
    • /
    • 2023
  • This study experimentally investigates the flexural behavior of steel-UHPC composite slabs composed of an innovative negative Poisson's ratio (NPR) steel plate and Ultra High Performance Concrete (UHPC) slab connected via demountable high-strength bolt shear connectors. Eight demountable composite slab specimens were fabricated and tested under traditional four-point bending method. The effects of loading histories (positive and negative bending moment), types of steel plate (NPR steel plate and Q355 steel plate) and spacings of high-strength bolts (150 mm, 200 mm and 250 mm) on the flexural behavior of demountable composite slab, including failure mode, load-deflection curve, interface relative slip, crack width and sectional strain distribution, were evaluated. The results revealed that under positive bending moment, the failure mode of composite slabs employing NPR steel plate was distinct from that with Q355 steel plate, which exhibited that part of high-strength bolts was cut off, part of pre-embedded padded extension nuts was pulled out, and UHPC collapsed due to instantaneous instability and etc. Besides, under the same spacing of high-strength bolts, NPR steel plate availably delayed and restrained the relative slip between steel plate and UHPC plate, thus significantly enhanced the cooperative deformation capacity, flexural stiffness and load capacity for composite slabs further. While under negative bending moment, NPR steel plate effectively improved the flexural capacity and deformation characteristics of composite slabs, but it has no obvious effect on the initial flexural stiffness of composite slabs. Meanwhile, the excellent crack-width control ability for UHPC endowed composite members with better durability. Furthermore, according to the sectional strain distribution analysis, due to the negative Poisson's ratio effect and high yield strength of NPR steel plate, the tensile strain between NPR steel plate and UHPC layer held strain compatibility during the whole loading process, and the magnitude of upward movement for sectional plastic neutral axis could be ignored with the increase of positive bending moment.

Studies on Repair of Reinforced Concrete Structures(II) - Their Influence on Flexural Performance - (철근콘크리트 구조물의 보수 공법연구(II) - 휨 거동 비교 -)

  • 김병국;신영수;홍기섭;이차돈;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.219-224
    • /
    • 1995
  • A series of 15 reinforced concrete beams was tested to explore the effects of polymer repair on damaged beams. The key parameters for this study were the repair materials, repair methods, repair depths and repair locations. The repaired specimens failed by a typical flexural mode, showing minor interface failure. The results show that epoxy, polyester resins and latex modified cementitous mortars are effective for repairing the concrete beams. The results also show that the depth and the location of the repair do not change significantly the flexural preformance of the repaired beams.

  • PDF