• Title/Summary/Keyword: flatbed scanner

Search Result 16, Processing Time 0.017 seconds

Analysis of the machinability of GFRE composites in drilling processes

  • Khashaba, Usama. A.;Abd-Elwahed, Mohamed S.;Ahmed, Khaled I.;Najjar, Ismail;Melaibari, Ammar;Eltaher, Mohamed A
    • Steel and Composite Structures
    • /
    • v.36 no.4
    • /
    • pp.417-426
    • /
    • 2020
  • Drilling processes in fiber-reinforced polymer composites are essential for the assembly and fabrication of composite structural parts. The economic impact of rejecting the drilled part is significant considering the associated loss when it reaches the assembly stage. Therefore, this article tends to illustrate the effect of cutting conditions (feed and speed), and laminate thickness on thrust force, torque, and delamination in drilling woven E-glass fiber reinforced epoxy (GFRE) composites. Four feeds (0.025, 0.05, 0.1, and 0.2 mm/r) and three speeds (400, 800, and 1600 RPM) are exploited to drill square specimens of 36.6×36.6 mm, by using CNC machine model "Deckel Maho DMG DMC 1035 V, ecoline". The composite laminates with thicknesses of 2.6 mm, 5.3 mm, and 7.7 mm are constructed respectively from 8, 16, and 24 glass fiber layers with a fiber volume fraction of about 40%. The drilled specimen is scanned using a high-resolution flatbed color scanner, then, the image is analyzed using CorelDraw software to evaluate the delamination factor. Multi-variable regression analysis is performed to present the significant coefficients and contribution of each variable on the thrust force and delamination. Results illustrate that the drilling parameters and laminate thickness have significant effects on thrust force, torque, and delamination factor.

The Creation of Dental Radiology Multimedia Electronic Textbook (멀티미디어기술을 이용한 치과방사선학 전자 교과서 제작에 관한 연구)

  • Kim Eun-Kyung;Cha Sang-Yun;Han Won-Jeong;Hong Byeong-Hee
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.55-62
    • /
    • 2000
  • Purpose: This study was performed to develop the electronic textbook (CD-rom title) about preclinical practice of oral and maxillofacial radiology, using multimedia technology with interactive environment. Materials and Methods: After comparing the three authoring methods of multimedia, i.e. programming language, multimedia authoring tool and web authoring tool, we determined the web authoring tool as an authoring method of our electronic textbook. Intel Pentium II 350 MHz IBM-compatible personal computer with 128 Megabyte RAM, Umax Powerlook flatbed scanner with transparency unit, Olympus Camedia l400L digital camera, ESS 1686 sound card, Sony 8 mm Handycam, PC Vision 97 pro capture board, Namo web editor 3.0, Photoshop 3.0, ThumbNailer, RealPlayer 7 basic and RealProducer G2 were used for creating the text document, diagram, figure, X-ray image, video and sound files. We made use of javascripts for tree menu structure, moving text bar, link button and spread list menu and image map etc. After creating all files and hyperlinking them, we burned out the CD-rom title with all of the above multimedia data, Netscape communicator and plug in program as a prototype. Results and Conclusions : We developed the dental radiology electronic textbook which has 9 chapters and consists of 155 text documents, 26 figures, 150 X-ray image files, 20 video files, 20 sound files and 50 questions with answers. We expect that this CD-rom title can be used at the intranet and internet environments and continuous updates will be performed easily.

  • PDF

Classification of Sole Types for Female High School Students by 2D scan data (2D 데이터에 의한 여고생의 발바닥 유형 분석)

  • Lee, Jeong-Eun;Do, Wol-Hee
    • Fashion & Textile Research Journal
    • /
    • v.15 no.6
    • /
    • pp.977-984
    • /
    • 2013
  • This study classified the type of sole for female high school students and analyzed the characteristics of each type by the shape of the sole (plantar view) using 2D scan data. The data were collected from a foot anthropometry of 310 female high school students in Gwangju and Jeollanam-do. Left feet and right feet were measured indirectly by using flatbed scanner. The sole anthropometric measurements consisted of 24 items. The results of the investigation into the differences between left and right feet soles by the 2D measurements data indicated that there was no significant statistical differences in the length of items. The left sole had higher values than right sole in the width items and angle items; however, the lateral side of the right feet projected to the outside more often than left feet. In analyzing foot sole of female high school students, the shapes of sole were classified into three types. Type 1(41.94%), Type 2(36.77%), Type 3(21.29%). The most characteristic sole type for female high school students was Type 1. Type 1 referred to a narrow foot width with little or no curvature of the toe. Type 2 represented the longest foot, with foot width shown as a spacious and distinctive feature in width at the medial area of the foot. Type 3 represented the shortest and widest of ball width, gathered inside toe 5, and lateral side as the most projected among the three types.

A STUDY ON THE RADIOPACITY OF ESTHETIC DENTAL MATERIALS USING IN THE PEDIATRIC DENTISTRY (소아용 심미수복재의 방사선 불투과성에 관한 연구)

  • Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.82-86
    • /
    • 2001
  • The aim of this study was to investigate the level of radiopacity of esthetic dental restorative materials and determine the optimum level of radiopacity in pediatric dentistry. Disks of 8 dental restorative material groups as the experimental group, 7mm in diameter and 2mm thick, were radiographed with intact human deciduous teeth and aluminum stepwedge standard. Radiopacity was evaluated with an image analysis program following the digitization of the radiographs using a flatbed scanner with transparency unit. All materials and tooth structure also the significant difference except FP, VB, VM. For the radiopacity of esthetic restorative dental materials to exceed that of enamel, it should be greater than 1.7mm of equivalent thickness of aluminum.

  • PDF

THE PRELIMINARY STUDY OF THE QUANTITATIVE MORPHOLOGIC ANALYSIS USING MRI OF THE LATERAL VENTRICLE IN EARLY-ONSET PSYCHOTIC DISORDER (조기 발병한 정신증적 장애에서 자기공명영상을 이용한 측뇌실에 대한 구조적인 예비연구)

  • Lee, Youn-Hee;Kang, Min-Hee;Kim, Chul-Eung;Bae, Jae-Nam;Hong, Kang-E;Lee, Jeong-Seop
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.12 no.2
    • /
    • pp.256-262
    • /
    • 2001
  • Objective:The enlargement of the lateral ventricle is well established finding in adult-onset schizophrenia, but in the patients with early-onset psychotic disorder(EOPD) is still controversal. To identify structural abnormalities of the lateral ventricle in patients with EOPD and difference of the brain developmental course in EOPD group, planimetrical assessment of the lateral ventricle was conducted by means of retrospective quantitative neuroimaging. Methods:The brain MR images of 14 patients with EOPD(mean age $14.0{\pm}2.1$ years) who met the DSM-III-R diagnostic criteria for schizophrenia and bipolar disorder and 24 control subjects with simple headache(mean age $10.0{\pm}2.1$ years) were collected. Single best view for the lateral ventricle, one axial slice was selected for analysis. MR images were redigitalized with flatbed scanner and data were analyzed with NIH IMAGE software. Results:In the patients with EOPD, there were significant correlations between aging and lateral ventricular sizes and between aging and ventricular brain ratio(VBR). The statistical significance of normal asymmetry of the lateral ventricle was not observed for the EOPD group. The EOPD group had larger lateral ventricular sizes and VBR than control group, but these results were not statistically significant. Conclusion:These findings suggest that the brain abnormalities in patients with EOPD progress from the earlier course of the disorders and the course of brain development in EOPD group is different from control group.

  • PDF

The evaluation of lens absorbed dose according to the Optimold for whole brain radiation therapy (전뇌 방사선치료 시 Optimold에 따른 수정체의 흡수선량 평가)

  • Yang, Yong Mo;Park, Byoung Suk;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.77-81
    • /
    • 2014
  • Purpose : In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. Materials and Methods : In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made ??up to 5mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. Results : When there was the Optimold mask in the eyeball part, it was measured at $10.2cGy{\pm}1.5$ in the simulation therapy, and at $24.8cGy{\pm}2.7$ in the treatment, and when the Optimold mask was removed in the eye part, it was measured at $12.9cGy{\pm}2.2$ in the simulation therapy, and at $17.6cGy{\pm}1.5$ in the treatment. Conclusion : In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3 cGy in the simulation therapy and was reduced approximately 7 cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause cataracts and side effects was considered to be reduced due to decrease of the absorbed dose to the eye lens which had the high sensitivity on the radiation.