• 제목/요약/키워드: flat-section

검색결과 250건 처리시간 0.027초

𝜂-Einstein Solitons on (𝜀)-Kenmotsu Manifolds

  • Siddiqi, Mohd Danish;Chaubey, Sudhakar Kumar
    • Kyungpook Mathematical Journal
    • /
    • 제60권4호
    • /
    • pp.805-819
    • /
    • 2020
  • The objective of this study is to investigate 𝜂-Einstein solitons on (𝜀)-Kenmotsu manifolds when the Weyl-conformal curvature tensor satisfies some geometric properties such as being flat, semi-symmetric and Einstein semi-symmetric. Here, we discuss the properties of 𝜂-Einstein solitons on 𝜑-symmetric (𝜀)-Kenmotsu manifolds.

Stiffening evaluation of flat elements towards stiffened elements under axial compression

  • Manikandan, P.;Arun, N.
    • Advances in Computational Design
    • /
    • 제3권1호
    • /
    • pp.71-86
    • /
    • 2018
  • Thin-walled cross-sections can be optimized to enhance their resistance and progress their behaviour, leading to more competent and inexpensive structural system. The aim of this study is to afford a methodology that would facilitate progress of optimized cold formed steel (CFS) column section with maximum ultimate strength for practical applications. The proposed sections are designed to comply with the geometrical standards of pre-qualified column standards for CFS structures as well as with the number of industrialized and practical constraints. The stiffening evaluation process of CFS lipped channel columns, a five different cross section are considered. The experimental strength and behaviour of the proposed sections are verified by using the finite element analysis (FEA). A series comprehensive parametric study is carried out covering a wide range of section slenderness and overall slenderness ratio of the CFS column with and without intermediate web stiffeners. The ultimate strength of the sections is determined based on the Direct Strength Specification and other design equation available from the literature for CFS structures. A modified design method is proposed for the DSM specification. The results indicate that the CFS column with complex edge and intermediate web stiffeners provides an ultimate strength which is up to 78% higher than standard optimized shapes with the same amount of cross sectional area.

선체외판의 변형이 수상함 RCS에 미치는 영향 연구 (Study on Effect of Shell Plate Deformation to Radar Cross Section of Warship)

  • 김국현;조대승
    • 대한조선학회논문집
    • /
    • 제48권6호
    • /
    • pp.509-515
    • /
    • 2011
  • The radar cross section (RCS) of warships is a crucial design factor to improve the survivability in terms of not only low observablity of the platform but also efficiency of on-board sensors and jamming devices against enemy threat. In design stage, numerical models are generated in order to quantitatively assess RCS, of which hull surfaces are modeled with the finite number of the flat plate. However, in practice, hull surfaces are permanently deformed by various kinds of loads such as winds and ocean waves faced during operations. In this paper, the effect of these shell plate deformation to RCS is numerically investigated. For this purpose, RCS calculations are carried out for various kinds of numerical models, such as single plates, dihedrals, large-sized undulate plates, and virtual warships, with some extent of permanent deformation. The results are compared with those of corresponding models without permanent deformation. It is concluded that the permanent deformation of hull surface highly influences RCS characteristics of warships, therefore they should be considered in the RCS analysis.

Experimental study on innovative tubular web RBS connections in steel MRFs with typical shallow beams

  • Saleh, Aboozar;Zahrai, Seyed M.;Mirghaderi, Seyed R.
    • Structural Engineering and Mechanics
    • /
    • 제57권5호
    • /
    • pp.785-808
    • /
    • 2016
  • An innovative Reduced Beam Section (RBS) connection, called Tubular Web RBS connection (TW-RBS), has been recently introduced and its performance has been numerically investigated in some earlier studies. The TW-RBS connection is a kind of accordion-web RBS connection in which part of the flat web of the beam is replaced by a steel tube at the expected region of the plastic hinge. This paper presents experimental results of three TW-RBS connections under cyclic loading. Obtained results indicated that TW-RBS reduces contribution of the beam web to the whole moment strength and creates a ductile fuse far from components of the beam-to-column connection. Besides, TW-RBS connection can increase story drift capacity up to 9% in the case of shallow beams which is much more than those stipulated by the current seismic codes. Based on the experimental results, the tubular web in the plastic hinge region improves lateral-torsional buckling stability of the beam such that only local buckling of the beam flange at the center of the reduced section was observed during the tests. In order to achieve a better understanding, behavior of all TW-RBS specimens are also numerically investigated and compared with those of experimental results.

Increasing plastic hinge length using two pipes in a proposed web reduced beam section, an experimental and numerical study

  • Zahrai, Seyed M.;Mirghaderi, Seyed R.;Saleh, Aboozar
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.421-433
    • /
    • 2017
  • Experimental and numerical studies of a newly developed Reduced Beam Section (RBS) connection, called Tubular Web RBS connection (TW-RBS) have been recently conducted. This paper presents experimental and numerical results of extending the plastic hinge length on the beam flange to increase energy dissipation of a proposed version of the TW-RBS connection with two pipes, (TW-RBS(II)), made by replacing a part of flat web with two steel tubular web at the desirable location of the beam plastic hinge. Two deep-beam specimens with two pipes are prepared and tested under cyclic loads. Obtained results reveal that the TW-RBS(II) like its type I, increases story drift capacity up to 6% in deep beam much more than that stipulated by the current seismic codes. Based on test results, the proposed TW-RBS(II) helps to dissipate imposed energy up to 30% more than that of the TW-RBS(I) specimens at the same story drift and also reduces demands at the beam-to-column connection up to 30% by increasing plastic hinge length on the beam flange. The TW-RBS(II) specimens are finally simulated using finite element method showing good agreement with experimental results.

DEVELOPMENT OF CONCRETE FILLED TUBE AS A PILLAR PILE FOR TOP DOWN METHOD

  • Jee-Yun Song;Hong-Chul Rhim;Seung-Weon Kim
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.808-813
    • /
    • 2009
  • Top-down method is widely used for urban area construction for its advantages in reducing environmental problems such as dust and noise, and saving construction cost depending on given conditions of a construction site. Because the excavation and construction of super- and sub-structures of the building have to be proceeded simultaneously, a column has to be embedded prior to excavation. This column is called a pillar column or pre-founded column. Usually a wide flange section is used for these columns. To place the columns, usually the diameter of casing holes needs to be larger than the section of the wide flange itself in order to accommodate a couple of tremie pipes for pouring concrete. In this paper, a newly developed method of using circular pipe as an alternative to the existing wide flange section is discussed. The crucial part of the new method is to develop a connection between the circular column and concrete flat slabs. For shear force transfer from concrete slab to the concrete filled tube (CFT) column, shear jackets with studs and shear bands are proposed. The studs are welded on the jackets at shop and placed around the circular column on site. The shear bands are welded on the outer side of the CFT at shop and inserted into ground with the CFT. Test results and application of the method to a construction site are also provided in this paper.

  • PDF

굴곡진 도로에서의 구간 선형 모델을 이용한 차선 검출 (Lane Detection on Non-flat Road Using Piecewise Linear Model)

  • 정민영;김경환
    • 한국통신학회논문지
    • /
    • 제39A권6호
    • /
    • pp.322-332
    • /
    • 2014
  • 본 논문에서는 굴곡진 도로를 구간 선형 모델로 근사화한 차선 검출 알고리즘을 제안한다. 기존의 차선 검출 알고리즘들은 지표면이 평면이라는 가정을 이용하기 때문에, 도로면이 굴곡진 실제 도로에서는 강건한 차선 검출이 어렵다. 제안하는 방법에서는 이 문제를 전체 차로를 구간으로 분할하고, 각 구간 내에서 차로를 가장 잘 근사하는 평면 차로를 구함으로써 해결한다. 이를 위해 각 구간 내에서 다양한 각도와 위치를 가지는 평면 형태의 구간 차로 후보들을 생성하였다. 구간 차로 후보들의 연결 조합 중 실제 차로에 가장 가까운 조합을 다이나믹프로그래밍을 이용하여 찾음으로써 굴곡진 차로를 근사한다. 평면 도로 뿐 아니라, 상하, 좌우의 굴곡이 있는 도로 영상으로 구성된 데이터세트에 대하여 제안하는 방법의 차선 검출 성능을 검증하였다. 평면 도로를 가정한 기존의 방법들이 80%에서 90% 초반의 검출률을 보이는 반면, 제안하는 방법은 90% 후반의 검출률을 보임을 통해 굴곡진 도로에서의 차선 검출의 강건성을 입증하였다.

슬래브-기둥 접합부에서 전단보강체에 정창성능에 따른 영향 (The Effect of Anchorage of Reinforcement in Slab-Column Connection)

  • 최현기;김준서;이문성;최창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.185-188
    • /
    • 2008
  • 플랫 플레이트 시스템은 펀칭전단과 같은 구조적 취약점이 있다. 펀칭전단의 저항력은 기둥단면의 증가, 슬래브 유효춤의 증가, 콘크리트 강도의 증가, 휨철근의 증가로 증가시킬 수 있다. 그러나 전단보강체를 설치하는 방법이 경제적, 시공적, 안정적으로 가장 좋은 방법이다. 하지만 슬래브 두께가 250mm보다 작은 슬래브에서는 전단보강체의 충분한 정착길이를 확보할수 없기 때문에 충분한 정착효과를 발휘하기 힘들다. 이전 연구에서 제안된 전단보강체의 경우 상부철근과 하부철근의 사이에 설치되었기 때문에 전단철근의 항복강도에 도달하기 전에 미끄러짐 파괴가 발생하였다. 정착강도의 영향을 주는 요인으로는 유효정착길이, 콘크리트강도, 전단철근의 직경, 정착상세이다. 본 연구에서는 슬래브 두께와 콘크리트 강도를 고려하여 제안된 보강체의 강도산정시 K factor를 제안하였다. 정착길이와 콘크리트강도를 고려함으로써 두께가 얇은 플랫플레이트 슬래브내에서 전단철근에 의한 전단강도를 정확히 산정할수 있을 것으포 판단된다..

  • PDF

CFT 기둥-RC 무량판 슬래브 외부접합부의 횡저항 성능 (Lateral Resisting Capacity for CFT Column to RC Flat Plate Slab Exterior Connections)

  • 송호범;송진규;오상원;김병조
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.61-64
    • /
    • 2008
  • 콘크리트충전 강관기둥(Concrete Filled steel Tube Column)과 RC 무량판 슬래브의 조합은 거푸집을 사용하지 않는다는 것만으로도 초고층 건물의 공기단축에 상당한 영향을 미칠 수 있다. 뿐만 아니라 기둥의 내력 증진으로 인한 기둥 크기의 축소, 그로 인한 공간 활용도의 증가, 층간 소음문제 해결 등 많은 장점이 잠재되어 있다. 하지만 접합부의 성능을 정확히 밝혀내는 것이 우선 이루어져야 하며, 본 논문에서는 기존에 수행된 CFT 기둥-RC 무량판 슬래브의 내부접합부에 대한 중력 실험과 횡하중 실험을 바탕으로 외부접합부에 대한 실물대 실험을 수행하였다. 외부접합부 실험 결과, 내부접합부 실험체에 비하여 동일한 조건에서 설계된 외부접합부 실험체는 최대 모멘트강도가 $50%{\sim}65%$ 감소하였고, 내진밴드가 추가된 CFT-E2 실험체는 BME 실험체에 비하여 20%의 최대모멘트 증진과 탁월한 연성능력, 에너지 흡수능력을 보유한 것으로 나타났다. 또한 CFT-E2는 내진밴드의 사용으로 슬래브의 휨거동 영역이 확장되었으며 모든 실험체가 설계기준에서 요구하는 0.4V$_c$중력하중 하에서 1.5% 횡변 위비를 만족하였다.

  • PDF

플랫 플레이트 외부접합부의 불균형모멘트에 관한연구 (A Study on Unbalanced Moment of Flat Plate Exterior Connections)

  • 최현기;백성우;백영수;진언식;최창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1-4
    • /
    • 2008
  • 플랫 플레이트 구조는 다른 구조형식에 비하여 매우 경제적인 구조형식이다. 그러나 횡하중을 받는 플랫 플레이트 구조는 슬래브-기둥 접합부의 뚫림전단파괴에 대해 취약하다. 플랫 플레이트 구조의 외부접합부는 편심전단에 대해 비대칭형의 위험단면을 가지고 있으며, 위험단면의 길이가 내부접합부 보다 작고 중력하중과 횡하중 모두에 의해 편심전다응력이 발생하게 되므로 뚫림전단파괴에 대해 매우 취약하다. 이에 본 논문에서는 플랫 플레이트 외부접합부의 실험결과와 기존 데이터를 바탕으로 ACI 318-05와 CEB-FIP MC 90의 설계기준식을 비교한 결과 편심전단응력, 불균형모멘트에 대해서 CEB-FIP식이 더 정확했고 형상비의 영향은 기둥 형상비가 큰 경우에는 기준식의 적용성에 문제가 있는 것으로 나타났다. 중력전단력비의 영향은 기준식의 제안을 만족하였으나 설계 기준에서는 단순히 중력전단비만 고려하고 있어서 다른 설계조건 변화에 따른 차이를 고려할 필요가 있다.

  • PDF