• 제목/요약/키워드: flat connections

검색결과 82건 처리시간 0.03초

CFT기둥-RC 무량판 접합부의 펀칭전단강도 및 거동 (Punching Shear Strength and Behavior of CFT Column to RC Flat Plate connections)

  • 이철호;김진원;이승동;안재권
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.168-179
    • /
    • 2006
  • This paper summarizes full-scale test results on CFT column-to-flat plate connections subjected to gravity loading. CFT construction has gained wide acceptance in a relatively short time in domestic building construction practice due to its various structural and construction advantages. However, efficient details for CFT column to flat plate connections have not been proposed yet. Based on the strategies that maximize economical field construction, several connecting schemes were proposed and tested. Test results showed that the proposed connections can exhibit punching shear strength and connection stiffness exceeding those of R/C flat plate counterparts. A semi-analytical procedure is presented to model the behavior of CFT column-to-flat plate connections. The five parameters to model elastic to post-punching catenary action range are calibrated based on the limited test data of this study. The application of the proposed modeling procedure to progressive collapse prevention design is also illustrated.

  • PDF

기둥 단면형상에 따른 플랫플레이트-기둥 접합부 강도에 관한 수치해석연구 (Numerical Analysis on Strength of Interior Flat Plate-Column Connections according to Column Section Shape)

  • 강수민;김욱종;이도범;박홍근;천영수;이현호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.291-294
    • /
    • 2005
  • In the present study, a numerical analysis was performed for interior connections of continuous flat plate to analyze the effect of column section shape on the behavioral characteristics of the connections. For the purpose, a computer program for nonlinear FE analysis was developed, and the validity was verified. Through the parametric study, the variations of shear stress distribution around the connection were investigated. According to the result of numerical analysis, the column section shape has a serious effect on the behavior of the connections. As the length of the cross section of column in the direction of lateral load increases, the effective area and the shear strength at the sides providing the torsional resistance decrease considerably. Therefore the strength model for the flat plate-column connections should be modified by considering the effect of column section shape on the behavior of the connections.

  • PDF

Development and evaluation of punching shear database for flat slab-column connections without shear reinforcement

  • Derogar, Shahram;Ince, Ceren;Mandal, Parthasarathi
    • Structural Engineering and Mechanics
    • /
    • 제66권2호
    • /
    • pp.203-215
    • /
    • 2018
  • A large body of experiments have been conducted to date to evaluate the punching shear strength of flat slab-column connections, but it is noted that only a few of them have been considered for the development of the ACI Code provisions. The limited test results used for the development of the code provisions fall short of predicting accurately the punching shear strength of such connections. In an effort to address this shortfall and to gain an insight into the factors that control the punching shear strength of flat slab-column connections, we report a qualified database of 650 punching shear test results in this article. All slabs examined in this database were tested under gravity loading and do not contain shear reinforcement. In order to justify including any test result for evaluation punching shear database, we have developed an approved set of criteria. Carefully established set of criteria represent the actual characteristics of structures that include minimum compressive strength, effective depths of slab, flexural and compression reinforcement ratio and column size. The key parameters that significantly affect the punching shear strength of flat slab-column connections are then examined using ACI 318-14 expression. The results reported here have paramount significance on the range of applicability of the ACI Code provision and seem to indicate that the ACI provisions do not sufficiently capture many trends identified through regression of the principal parameters, and fall on the unsafe side for the prediction of the punching shear strength of flat slab-column connections.

Effective Beam Width Coefficients for Lateral Stiffness in Flat-Plate Structures

  • Park, Jung-Wook;Kim, Chul-Soo;Song, Jin-Gyu;Lee, Soo-Gon
    • KCI Concrete Journal
    • /
    • 제13권2호
    • /
    • pp.49-57
    • /
    • 2001
  • Flat-plate buildings are commonly modeled as two-dimensional frames to calculate unbalanced moments, lateral drift and shear at slab-column connections. The slab-column frames under lateral loads are analyzed using effective beam width models, which is convenient for computer analysis. In this case, the accuracy of this approach depends on the exact values of effective beam width to account for the actual behavior of slab-column connections. In this parametric study, effective beam width coefficients for wide range of the variations are calculated on the several types of slab-column connections, and the results are compared with those of other researches. Also the formulas for effective beam width coefficients are proposed and verified by finite element analysis. The proposed formulas are founded to be more suitable than others for analyzing flat-plate buildings subjected to lateral loading.

  • PDF

래티스형 철근을 이용한 무량판 구조의 접합부 전단보강 (Shear Reinforcement for Flat Plate-Column Connections using Lattice Bars)

  • 안경수;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.587-590
    • /
    • 2003
  • In flat-plate floors, slab-column connections are broken down with a brittle shear failure. And it can cause the collapse of the whole structures. Thus, the proper method of shear reinforcement in flat plate-column connections must be required. The objective of this study is to compare shear reinforcement specimens using lattice bars to no shear reinforcement specimens in view of shear strength and ductility of the flat plate-column connections. The test results have shown that shear reinforcement specimens varying $\rho$, $b_0$/d and $C_1$/$C_2$ increase in shear strength by 36.85% and in ductility by 9.16 for no shear reinforcement specimens on the average. This results confirm the effectiveness of this type of shear reinforcement in improving shear strength and ductility.

  • PDF

불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부의 변형능력과 내진설계방법 (Seismic Design and Deformability of Interior flat Plate-Column Connections Subjected to Unbalanced Moment)

  • 최경규;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.117-122
    • /
    • 2002
  • Flat Plate structures subjected to lateral load are susceptible to the brittle failure, therefore deformability of plate-column connections should be ensured to resist against earthquake. However, according to previous study, existing experiments overestimate the deformability of connections and current design provision do not accurately explains them. In the present study, parametric study using nonlinear finite element analysis was performed. Based on the numerical results, seismic design method considering the deformability of connections was developed.

  • PDF

CFT기둥 철근콘크리트무량판 접합부 상세 및 설계법 개발을 위한 실험연구 (An Experimental Study for Development of Details and Design Method of CFT Column-to-RC Flat Plate Connections)

  • 이철호;김진원;이진혁;박철수;오정근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.203-210
    • /
    • 2005
  • This paper summarizes full-scale test results on CFT column to flat plate connections subjected to gravity loading. CFT construction has gained wide acceptance in a relatively short time in domestic building practice due to its various structural and construction advantages. Constructing the floor as flat plate is often regarded as being essential for both cost savings and rapid construction. However, efficient details for CFT column to flat plate connections have not been proposed yet, and their development is urgently needed. Based on some strategies that include maximizing economical field construction, several connecting schemes were proposed and tested in this study. Test results showed the proposed connection details can exhibit strength and stiffness comparable to or greater than those of R/C flat plate counterpart.

  • PDF

PT 플랫 플레이트와 RC 플랫 플레이트 내부 접합부의 구조적 거동 비교에 관한 실험적 연구 (An Experimental Study on Comparison of Structural Behavior of PT Flat Plate and RC Flat Plate Interior Connections)

  • 이동근;하상수;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.111-114
    • /
    • 2005
  • While the existing reinforced concrete flat plate(RC flat plate) has a lot of advantages including reduced building height, it has some weak points such as many steel bars and the brittle rupture by punching shear. Compared with the RC flat plate, the post-tensioned flat plate (PT flat plate) has not only the same merits, but it also makes longer span possible and induces slab-column connections to be failed with the ductile behavior rather than with the brittle behavior by means of post-tensioning. However, it is difficult to define the joint behavior of PT flat plate under vertical and lateral loads since there are limit experimental results. For this reason, the experimental study is undertaken to investigate the comparison of behavior of PT flat plate and RC flat plate, and how flat plate(Gravity Load Resisting System) is displaced as lateral loads, like the wind and the earthquake, are occur. The result of this experiment shows that PT flat plate is generally superior to RC flat plate in terms of controlling crack, postponing stiffness deterioration, energy dissipation, etc.

  • PDF

CFT기둥-RC 무량판 접합부의 펀칭전단강도 및 거동 (Punching Shear Strength and Behavior of CFT Column to RC Flat Plate connections)

  • 이철호;김진원
    • 한국강구조학회 논문집
    • /
    • 제18권4호
    • /
    • pp.491-502
    • /
    • 2006
  • 본 논문은 중력하중의 지배를 받는 CFT기둥-RC 무량판 접합부의 실물대 실험결과를 요약한 것이다. CFT구조는 여러 가지 구조및 시공상의 장점으로 인하여 국내 건설 현장에서 상대적으로 짧은 시간에 폭넓게 수용되고 있다. 주차장 용도로 주로 사용되는 지하층은 철근콘크리트 무량판으로 시공하여 경제성을 도모하는 것이 국내에서 일반적으로 요구되는 시공관행이다. 그러나 CFT기둥-R C 무량판 접합부의 효율적인 디테일은 아직 국내 외적으로 제시된 바가 없어서 이 분야의 연구가 매우 필요한 실정이다. 현장 시공시 경제성을 극대화할 수 있는 몇 가지 전략을 기초로 해서, 여러가지 접합 상세를 제안하였고 실험을 통하여 검증하엿다. 실험결과 본 연구에서 제시된 CFT기둥-RC 무량판 접합 상세의 펀칭강도 및 강성이 RC 무량판 접합부와 동등하거나 이를 상회하는 것을 확인할 수 있었다. CFT기둥-RC 무량판 접합부의 초기 탄성거동에서 펀칭파괴이후 휨철근의 국부 현수작용에 이르기까지의 모델링 방안을 제시하고 본 연구의 실험결과를 기초로 5개의 모델링 변수를 캘리브레이션하였다. 또한 무량판구조의 연쇄붕괴방지 설계에 본 연구의 결과를 응용하는 방안을 사례를 통하여 예시하였다.

Morse inequality for flat bundles

  • Kim, Hong-Jong
    • 대한수학회지
    • /
    • 제32권3호
    • /
    • pp.519-529
    • /
    • 1995
  • Let M be a compact smooth manifold of dimension n and let E be a flat (complet) vector bundle over M of rank r.

  • PDF