• Title/Summary/Keyword: flashing

Search Result 108, Processing Time 0.025 seconds

THINNED PIPE MANAGEMENT PROGRAM OF KOREAN NUCLEAR POWER PLANTS

  • Lee, S.H.;Lee, Y.S.;Park, S.K.;Lee, J.G.
    • Corrosion Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • Local wall thinning and integrity degradation caused by several mechanisms, such as flow accelerated corrosion (FAC), cavitation, flashing and/or liquid drop impingements, are a main concern in carbon steel piping systems of nuclear power plant in terms of safety and operability. Thinned pipe management program (TPMP) had been developed and optimized to reduce the possibility of unplanned shutdown and/or power reduction due to pipe failure caused by wall thinning in the secondary side piping system. This program also consists of several technical elements such as prediction of wear rate for each component, prioritization of components for inspection, thickness measurement, calculation of actual wear and wear rate for each component. Decision making is associated with replacement or continuous service for thinned pipe components. Establishment of long-term strategy based on diagnosis of plant condition regarding overall wall thinning is also essential part of the program. Prediction models of wall thinning caused by FAC had been established for 24 operating nuclear plants. Long term strategies to manage the thinned pipe component were prepared and applied to each unit, which was reflecting plant specific design, operation, and inspection history, so that the structural integrity of piping system can be maintained. An alternative integrity assessment criterion and a computer program for thinned piping items were developed for the first time in the world, which was directly applicable to the secondary piping system of nuclear power plant. The thinned pipe management program is applied to all domestic nuclear power plants as a standard procedure form so that it contributes to preventing an accident caused by FAC.

LED IT-based System sensor network transceiver module research (LED IT 기반 시스템 센서 네트워크 송수신 모듈 연구)

  • Jang, Tae-Su;Lee, Jun-Myung;Choi, Jung-Won;Kim, Yong-kab
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.11-12
    • /
    • 2012
  • In this paper, efficient visible light communication technology LED (Light Emitting Diode) lighting through the existing infrared sensor used for performance analysis of transmitting and receiving is possible. LED utilizes lighting by changing light into electricity. Lighting features while maintaining the basic principles of flashing LED and PD (Photo Diode) to send and receive communications from LED lighting communication convergence principle be realized simultaneously enabling. Multiple IT applications under the basic structure of LED technology development, and the current was encountered in real life. LED lighting anywhere with wireless communication technology that can, in order to ~ 1m above the initial value by taking advantage of the system H/W and infrared sensors(PD) are widely used in the entire system that can improve the speed of visible light data transmission system is finished. LED module that is used to communicate whether the performance analysis, For forecasting and communication distance on the LED and infrared sensor configuration of the implementation of the research is to study about the possibility of application methods and indicates.

  • PDF

Thermo-Hydrodynamic Behaviors of Open Channel Flow Inside A Multi-Stage Flash Evaporator (다단 후래시 증발장치내 개수로 유동의 열.수력학적 거동)

  • 설광원;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.702-715
    • /
    • 1990
  • This paper describes behaviors of two-phase open channel flow inside the flash chamber of a horizontal Multi-Stage-Flash evaporator numerically along with the experimental observations. Bubble trajectories and the velocity and temperature distributions of the liquid phase were predicted by using the particle-source-in-cell(PSI-Cell) method with the appropriate bubble motion/growth equations. Size and number of bubble nuclei embedded in the incoming liquid(brine) were taken into account as important parameters in addition to the conventional ones such as the velocity, degree of inlet superheat, inlet opening height, and the liquid level. Bubble motions, which are unsteady, appeared to be mostly determined by the buoyancy and the drag forces. The calculations, though a number of simplifying assumptions were made, reasonably simulated the hydrodynamic behaviors of the two-phase horizontal stream observed in the experiments. The simulated temperature distributions also agreed fairly well with the other's measurements. Non-equilibrium allownaces, evaluated from the simulated temperature distributions, were within the range of those obtained from the existing correlations, and reduced with the increases of the number and size of incoming bubble nuclei due to vigorous flashing.

Evaluation of Liquid Droplet Impingement Erosion through Prediction Model and Experiment (예측모델 및 실험을 통한 액적충돌침식 손상 평가)

  • Yun, Hun;Hwang, Kyeong-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1105-1110
    • /
    • 2011
  • Flow-accelerated corrosion (FAC) is a well-known phenomenon that may occur in piping and components. Most nuclear power plants have carbon-steel-pipe wall-thinning management programs in place to control FAC. However, various other erosion mechanisms may also occur in carbon-steel piping. The most common forms of erosion encountered (cavitation, flashing, Liquid Droplet Impingement Erosion (LDIE), and Solid Particle Erosion (SPE)), have caused wall thinning, leaks, and ruptures, and have resulted in unplanned shutdowns in utilities. In particular, the damage caused by LDIE is difficult to predict, and there has been no effort to protect piping from erosive damage. This paper presents an evaluation method for LDIE. It also includes the calculation results from prediction models, a review of the experimental results, and a comparison between the UT data in the damaged components and the results of the calculations and experiments.

Comparison Between FAC Analysis Result Using ToSPACE Program and Experimental Result (ToSPACE 프로그램을 이용한 FAC 해석결과와 실험결과 비교)

  • Hwang, Kyeongmo;Yun, Hun;Seo, Hyukki;Jung, Euije;Kim, Kyungmo;Kim, Dongjin
    • Corrosion Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.131-137
    • /
    • 2020
  • A number of piping components in the secondary system of nuclear power plants (NPPs) are exposed to aging mechanisms, such as flow-accelerated corrosion (FAC), cavitation, flashing, solid particle erosion, and liquid droplet impingement erosion. Those mechanisms may lead to thinning, leaking, or rupture of the components. Due to the pipe ruptures caused by wall thinning in Surry unit 2 in the USA in 1986 and Mihama unit 3 in Japan in 1994, pipe wall thinning management has emerged as one of the most important issues in the nuclear industry. To manage pipe wall thinning, a foreign program has been utilized for NPPs in Korea since 1996. As our experience and knowledge of pipe wall thinning management have accumulated, our program needs to reflect our experience, requests from users, and the result of recent experiments using Flow Accelerated Corrosion Testing System (FACTS). FACTS is the empirical experimental facility developed by Korea Atomic Energy Research Institute (KAERI) for tests. Accordingly, KEPCO-E&C developed a 3D-based pipe wall thinning management program called ToSPACE in 2016. This paper describes a comparison between the FAC analysis results using ToSPACE and the experimental results using FACTS to verify their applicability to pipe wall thinning management in NPPs.

Smart Harness for Preventing Pet Loss Outdoors (실외에서 애완견 분실 방지를 위한 스마트 어깨줄)

  • Lee, Jun-Hyeok;Ruy, Se-Hyun;Lim, Jong-Chan;Chou, Tea-Hyun;Han, Yeong-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.709-718
    • /
    • 2021
  • In this paper, it can be seen that the number of abandoned dogs increases every year through the statistics on the occurrence of abandoned animals. With the goal of reducing the number of stray dogs, a smart pet dog shoulder strap is implemented based on a real-time location tracking system using the ESP32 module and GPS sensor. It is an ESP32 module with a built-in Bluetooth module. It is input to the MCU using various sensors, and finally outputs to a smart-phone application, and communicates through the built-in blue-tooth module. In addition, it uses Neopixels to compensate the weaknesses at night through LED light emission, and automatically sets the warning distance to design a music playback system through the LED flashing effect and MP3 module. In addition, a smart pet dog shoulder strap was designed to help pet dog health care by measuring the moving distance according to the amount of activity through the gyro sensor.

A Rare Case of Brain Abscess Caused by Aggregatibacter aphrophilus and Actinomyces georgiae in an Immunocompetent Child

  • Soojeong Bae;Su Jin Lee;Ye Kyung Kim;Hee-Won Moon;Kyung Rae Cho;Ran Lee
    • Pediatric Infection and Vaccine
    • /
    • v.30 no.3
    • /
    • pp.159-164
    • /
    • 2023
  • A brain abscess is a potentially life-threatening infection of the brain that can be challenging to diagnose, especially in children. In this report, we describe a case of a central nervous system infection caused by rare pathogens in an immunocompetent child. A 10-year-old female presented with a severe headache lasting 10 days, along with flashing lights, nausea, and vomiting. The patient was diagnosed with secundum atrial septal defect 7 years ago and underwent dental work for cavities one month prior to admission. Brain magnetic resonance imaging (MRI) showed a 4.2 cm sized brain abscess in the right parietal lobe, causing left inferior quadrantanopia. A craniotomy and abscess aspiration surgery were performed, and cultures from the aspirated pus and tissue revealed Aggregatibacter aphrophilus. Additionally, Actinomyces georgiae was identified through 16S rRNA sequencing. After 8 weeks of antimicrobial therapy with ampicillin-sulbactam, the patient was discharged without any complications. A follow-up brain MRI showed complete resolution of the abscess and edema.

Rheological behavior and IPL sintering properties of conductive nano copper ink using ink-jet printing (전도성 나노 구리잉크의 잉크젯 프린팅 유변학적 거동 및 광소결 특성 평가)

  • Lee, Jae-Young;Lee, Do Kyeong;Nahm, Sahn;Choi, Jung-Hoon;Hwang, Kwang-Taek;Kim, Jin-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.5
    • /
    • pp.174-182
    • /
    • 2020
  • The printed electronics field using ink-jet printing technology is in the spotlight as a next-generation technology, especially ink-jet 3D printing, which can simultaneously discharge and precisely control various ink materials, has been actively researched in recent years. In this study, complex structure of an insulating layer and a conductive layer was fabricated with photo-curable silica ink and PVP-added Cu nano ink using ink-jet 3D printing technology. A precise photocured silica insulating layer was designed by optimizing the printing conditions and the rheological properties of the ink, and the resistance of the insulating layer was 2.43 × 1013 Ω·cm. On the photo-cured silica insulating layer, a Cu conductive layer was printed by controlling droplet distance. The sintering of the PVP-added nano Cu ink was performed using an IPL flash sintering process, and electrical and mechanical properties were confirmed according to the annealing temperature and applied voltage. Finally, it was confirmed that the resistance of the PVP-added Cu conductive layer was very low as 29 μΩ·cm under 100℃ annealing temperature and 700 V of IPL applied voltage, and the adhesion to the photo-cured silica insulating layer was very good.

A Study of the Intersection in Reduce Car Accidents for Traffic Signal Light to Supplement (교차로 사고 감소를 위한 신호등 보완에 관한 연구)

  • Park, In-Deok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.296-301
    • /
    • 2020
  • Three types of traffic signal systems are two-color signal systems that flash red and green and are mainly used on crosswalks, next, three-color equalization systems mainly used at T-shaped intersections with red and yellow lights and a green arrow, and third, four-color intersections that generally have red, yellow and green colored lights and a green arrow. In what is known as the "dilemma zone" area, a driver collects information that influences his/her decision whether to stop, speed, tail, interrupt, or violate a traffic light, depending on the intersection width, vehicle speed, cognitive response time and reference yellow signal time. This study examined the impact of changes in the length of the dilemma zone areas based on changes in yellow signal times, the speed of the intersection passages, and signal lamps. Downward adjustments of 50km/h and 60km/h affected yellow signal time. The yellow signal time increased by 0.1 to 2.3[s] due to this effect and the dilemma zone area increased by 1.22 to 26[m]. The driver of the dilemma zone could quickly decide to reduce the time remaining of the straight (3color, 4color) green signal to reduce the potential of a traffic accident at the intersection traffic. Safe entry of red (LED palm) and left-turn signals for entering flashed at the intersection and operated at midnight.

A Study on the Hazardousness and the TLV in Working Environments of Benzine (벤진의 유해 위험성과 작업환경 노출기준 연구)

  • Kim, Hyeon-Yeong;Lee, Sung-Bae;Han, Jung-Hee;Shin, Jea-Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.233-244
    • /
    • 2006
  • Of many volatile organic detergents for metals, benzine(CAS No. 8030-30-6), of which the toxicity has not yet been proven, has been used as an alternative of the halide compounds in the consideration of toxic effects, global warming and the destruction of ozone layer. In order to evaluate the effects of the benzine on human body by investigating the subchronic inhalation toxicity, to obtain the basic data for establishing the criteria of exposure in working environments and to classify the hazardousness in compliance with the Industrial Safety and Health Act by evaluating the hazardousness, repeated inhalation exposure test was carried with SD rats. The rats were grouped by 10 females and males each. The repetitive inhalation exposures were carried out at 4 levels of concentration of 0 ppm, 60 ppm, 300 ppm, and 1,500 ppm, for 6 hours a day, 5 days a week, for 13 weeks. The results are described hereunder. 1. No death of the animals of the exposed and controlled groups in the test period. Not any specific clinical symptoms, change in feed intake quantity, abnormality in eye test, or change in activity were observed. 2. In the 300 ppm and 1,500 ppm groups, weight reduction in the female groups and weight increase of liver and kidney in the male groups compared with control group were observed with statistical significance(p<0.05). 3. In the blood test, the HCT increased in the male 300 ppm group and the number of hematocyte increased, MCV and MCH decreased in the male 1,500 ppm group. In the female 1,500 ppm group, the HB decreased and the distribution width of the hematocyte particle size increased. In the blood biochemistry test, the TP in the male 1,500 ppm group and the LDH in the female 1,500 ppm group were increased with statistical significance(p<0.05). 4. Under the test conditions of the present study with SD rats, the NOEL was evaluated to be from 60 ppm to 300 ppm for both male and female groups. By extrapolation, the NOEL for human who work 8 hours a day was evaluated to be from 128 ppm to 640 ppm 5. Since the NOEL evaluated in this study do not exceed 60ppm(0.184 mg/L) the test material does not belong to the classification of the hazardous substance "NOEL${\leq}$0.5mg/L/6hr/90day(rat), for continuous inhalation of 6hours a day for 90 days" nor to the basic hazardous chemical substance class 1(0.2 mg/L/6hr/90day(rat) defined by the GHS which is a criteria of classification and identification of chemical compounds. However, considering the boiling point($30-204^{\circ}C$), flashing point($-40^{\circ}C$), vapor pressure(40 mmHg), and the inflammable range(1.0 - 6.0 %), sufficient care should be taken for handling in the safety aspects including fire or explosion.