• Title/Summary/Keyword: flame test

Search Result 543, Processing Time 0.026 seconds

Combustion Characteristics of Water Emulsified Fuel by Using Swirl Impinging Mixer (와류 충돌형 혼합장치를 이용한 물혼합 연료의 연소특성)

  • Kwak, I.S.;Han, J.H.;Lee, H.S.;Park, K.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.852-857
    • /
    • 2001
  • This paper discusses the combustion characteristics of water emulsified fuel produced by swirl impinging mixer. The experiments are given in a test boiler and a commercial boiler. Flame temperatures, flame shapes and exhaust emissions are measured in the test boiler, and thermal efficiency is tested in the commercial boiler. The test data show the water in oil makes the flame wider and shorter, the flame temperature lower and the NOx and smoke lower. Also, the commercial boiler test shows the thermal efficiency increases as well as the emissions decrease.

  • PDF

Tumble flow motion and flame propagation in a SI engine (SI 엔진의 텀불 유동과 화염전파)

  • Jie, Myoung-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.155-163
    • /
    • 1999
  • In this study, single cylinder engines with different tumble ratio were made to find out in-cylinder fluid motion and flame propagation. Tumble ratio derived from the steady state flow rig test. Flame propagation speed was obtained using cylinder head gasket ionization probe and the piston ionization probe. And the combustion pressure in cylinder was measured to analyze the combustion characteristics. In case of high tumble engine, BSFC and BSHC were decreased and BSNOx was increased at part load test. Also BMEP and combustion peak pressure was increased at full load test. Tumble flow motion had an great effects on initial burning period rather than main burning period in part load test.

  • PDF

A Study on the Improvement for Sensitivity Test of Flame Detectors (불꽃화재감지기의 시험기준 개선에 관한 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.58-61
    • /
    • 2014
  • Flame detectors has been used more than heat & smoke detector, because this is more effective to catch fire and ceiling height in spite of high price. For upgrade to flame detector, Compare to national or abroad standard about performance test, sensitivity test, sectioning indoor or outdoor, after service and management. As a result, Europe and America have only sensitivity test, no have not operation test and sectioning indoor & outdoor. In performance test, action is put to focus to credit and durability, Not operation test is to be able to tune the sensitivity to match the environment of the site. Also, we need code about aftercare, quality assurance responsibility and implement special detector institution by Certificate Authority implement.

Flame deflector design of test facility to propulsion system model (추진기관 시스템 시험설비의 화염유도로 설계)

  • Jeon, Sung-Bok;Lee, Jae-Ho;Lee, Kwang-Jin;Cho, Nam-Kyung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.597-602
    • /
    • 2012
  • Flame deflector is an important plan item for protecting propulsion system model, test facility, and life. This study suggests the way of flame deflector design in test facility evaluating performance of 75 ton and 300ton PSM. The flame deflector height was designed as 30m using a slope way in establishment location of facility. The flame deflector suitability was considered according to the shape of open and closed type. Also the cooling duct was made as modeling in accordance with core and side injection type.

  • PDF

Dyeing and Flame-retardant Properties of Low melting yarn

  • Hwang, Se-Jeong;Min, Mun-Hong;Son, Hyun-Sik;Kim, Chang-Nam;Lee, Gyu-Hwan
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2010.03a
    • /
    • pp.167-168
    • /
    • 2010
  • Non coating type Low melting yarn(L/M PET) not to use the polyurethane resin causing some problems was knitting and evaluated its dyeing characteristics, heat setting properties and flame-retardant properties without flame retardant agent or flame retardant fabric. In order to investigate the dyeing property of fabric of L/M PET, the dyeing of L/M PET was experimented at each different dyeing temperature. Higher exhaustion yield was achieved at lower temperature of L/M PET compared to regular PET. According to result of the study for the heat setting properties of L/M fiber, the K/S value of dyed L/M fiber increased as much as the heat setting temperature did. The experiment for the light fastness reached similar result to dyed PET. However washing fastness in L/M fiber showed lower grade compared with regular PET. flame-retardant efficiency of L/M PET without flame retardant agent or flame retardant fabric measured by $45^{\circ}$ burn test and Contact burn test. The flame?retardant performance of the sample was carried out according to the Korea Fire-fighting Standard.[KOFEIS 1001].

  • PDF

Preparation and Characterization of Polyurethane Flame-Retardant Coatings Containing Trichloro Lactone Modified Polyesters (트리클로로 락톤 변성폴리에스테르를 함유한 폴리우레탄 난연도료의 제조 및 난연특성)

  • 정충호;박형진;김성래;우종표;김명수
    • Polymer(Korea)
    • /
    • v.26 no.2
    • /
    • pp.200-208
    • /
    • 2002
  • Two-component polyurethane flame-retardant coatings were prepared by blending trichloro lactone modified polyesters (TAPTS) and isocyanate, Desmodur IL. Polycondensation reaction of trichlorobenzoic acid (TBA) as a flame-retardant component, and adipic acid with trimethylolpropane, polycaprolactone 0201, and 1,4-butanediol gave the corresponding TAPTs. The content of TBA was adjusted from 10 to 30 wt% in our experiment. It was found that various properties of these new flame-retardant coatings were comparable to other non-flame-retardant coatings. We also carried out three different tests for the measurement of flammability of flame -retardant coatings. The results of vertical burning test for the coatings containing more than 20 wt% of TBA were determined as 'no burn'. The results of flammability test for the coatings with 20 and 30 wt% of TBA contents indicated the limiting oxygen index (LOI) values of 25% and 27% respectively, which implied relatively good flame retardancy. They also showed the char length of 3.6-5.2 cm according to $45^{\circ}$ Meckel burner test, which can be classified as the first grade flame-retardant coatings.

Flame Resistance and Durability of Compressed Structural Wood through Microwave Heat Drying Method (마이크로파 가열건조법에 의한 압축 구조용 목재의 방염 및 내구성)

  • Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.162-170
    • /
    • 2011
  • As the result of implementing a treated material test and durability test after quickly drying S.P.F. species, a type of softwood structural material, within a short period time, soaking it in liquid phosphate flame proof agent for an hour, microwave heating it, and compressing it from 3.8cm to 1cm, when setting the appropriate heating time of microwave heating at 7 minutes at 5kW, it is observed that it satisfies the target water content (4~5%). It is shown that in a water content measurement of the wood that is compressed after being softened by soaking in the flame proof agent, drying and heating at 3kW for 9 minutes, all specimens satisfied 12~14%, the appropriate water content for exterior wood. Also, it is shown that in terms of the flame performance obtained through a flame resistance treatment of the compressed wood and a treated material test, the specimen soaked in flame proof agent for 30 minutes was the most excellent, and that the performance test result of the compressed wood in all areas, such as nail withdrawal resistance, compression, bending strength, and shearing strength, were all improved in their mechanical features to twice to three times better performances.

A Study on the Flame Resistance Performance and Smoking Characteristics of the Flame-Resistant Paint (방염도료의 방염성능 및 발연특성에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.78-83
    • /
    • 2009
  • 17 kinds of fire resistant paint which are currently used were painted on the MDF, to find flame resistance performance and smoking characteristics according to principal ingredient and characteristics of fire resistant paint. 45 degree combustion test and smoke density test were conducted to investigate the flame resistance performance and smoking characteristics. According to the 45 degree combustion test, acrylic resin type fire resistant paint showed the most excellent fire resistance performance. And the water soluble fire resistant paint showed better fire resistance performance compare to the solvent soluble paints. Also gloss paint showed better fire resistance performance than the flat paint. Based on the smoke density test, the smoke generation of fire resistant treated specimen of acrylic resin type was least. And the water soluble fire resistant paint generate little smoke than solvent soluble fire resistant paint.

Comparison Study on Quality Characteristics of Surface Treatment of Stone Board Materials by Water-jet System and Flame-burner (워터젯 수압분사와 화염버너에 의한 석판재 표면처리의 품질특성 비교연구)

  • 강지호;장명환
    • Journal of the Korea Safety Management & Science
    • /
    • v.5 no.1
    • /
    • pp.115-128
    • /
    • 2003
  • To comparison the surface treatment methods of stone board materials, the results of Dorry's abrasive test were 23.4 for water-jet system and 18.9 for flame-burner system. Therefore abrasive hardness, the stone board materials by the water-jet system was greater than one by flame-jet system. As a result of Shore's hardness test, the stone board materials by water-jet system was twice greater than one by flame-jet system. Authors carried out microscopic observation to survey a defection of the composition minerals for two methods, but all of the both methods have not founded a defection. Therefore, the stone board materials by water-jet system was greater durability than one by flame-jet for the surface treatment methods.

Fire Resistance Properties of Chloroprene Rubber containing Inorganic Flame Retardant

  • Sung, Il Kyung;Park, Chan Young
    • Elastomers and Composites
    • /
    • v.50 no.4
    • /
    • pp.279-285
    • /
    • 2015
  • This study examined the mechanical properties and the flame retardant properties of CR rubber containing inorganic flame retardant with various contents of aluminium trihydroxide (ATH, $Al(OH)_3$). The content of aluminium trihydroxide was added in 0, 30, 50, 70 and 100 phr for T1~T5 samples. It was found that increasing the amount of addition over 30 phr resulted in decreasing the mechanical properties. On the other hand in oxygen index measurements T1 sample showed a value of 38.6%, indicating the improvement of flame retardant properties showed a value of 49.7~64.2%. In case of burn test, it was confirmed that CR rubber containing over ATH 50phr content showed performance corresponding to that of first grade fire-resistance.