• Title/Summary/Keyword: flame resistant

Search Result 82, Processing Time 0.021 seconds

An experimental study on flame resistant performance by flame resistant method and agents (방염법 및 방염액 종류별 방염성능에 관한 실험적 연구)

  • Lim, Nam-Gi;Her, Jae-Won;Park, Cheul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.6
    • /
    • pp.117-122
    • /
    • 2008
  • This study targets to improve and complement the problem of existing flame resistant processing with flame resistant performance the same as existing flame resistant agents or better, keeping wooden surface & feel as they are, and to attempt to raise flame resistant performance and economic efficiency by applying phosphorous flame resistant agents, a colorlessness, odorless new product to woods for an improvement of flame resistant performance for wooden nature and to offer a basic data for an uniform high-performance for flame resistant woods by reinforcing wooden durability and usability.

Study on the Internal Temperature of Flame Resistant Treated Wood Exposed to a Standard Fire (표준화재에 노출된 방염처리 목재의 내부온도에 관한 연구)

  • Kim, Hwang-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.14-18
    • /
    • 2018
  • The earlier studies on the fire resistance performance of woods used as building materials have focused on confirming combustion characteristics of fire retardant or flame resistant treated wood. In this paper, to confirm internal temperature changes closely related to pyrolysis of woods exposed to the flame, heating experiments were conducted in a heating furnace according to the standard heating temperature curves after Douglas-fir, which is widely used as structural materials, was treated with a flame resistant solution and flame retardant paint. As a result of the experiment, it was confirmed that the thermal diffusion inside the wood has decreased when the wood was treated with the flame resistant solution. However, in high temperature, the flame resistant effect could not be expected due to the peeling of the coating in the case of the flame resistant paint treated wood. Therefore, it can be considered that it is more effective to use the flame resistant solution which penetrates in to the inside of the wood than flame resistant paint which forms the coating on the surface of the wood in order to enhance the flame resistance effect on the thick wood.

A Study on the On-site Flame Resistant Inspection Method by X-ray Fluorescence Spectrometer (X-선 형광분석기를 이용한 현장방염검사방법에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.124-129
    • /
    • 2016
  • According to the current law, on-site flame resistant-treated interior decorations should pass the flame resistant performance test through a 45 degree combustion test from the district fire department. Although a 45 degree combustion test is the most accurate method for determining the flame resistant performance, it can be unreliable when tested on unauthorized samples. To avoid unauthorized sampling, this study suggests on-site flame resistant inspection by X-ray fluorescence spectrometer. Ten types of flame resistant paint were spread on plywoods and MDFs and the components were analyzed by X-ray fluorescence spectrometer. As a result, due to a difference amounts of substances in each paint, each flame resistant paints showed its own characteristic spectrum and the contents of each substance could be determined. On-site flame resistant inspections can be used efficiently when institutional procedures are created.

A Study on the On-site Flame Resistant Treatment in Domestic (국내 현장방염 시공의 실태분석 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.33-38
    • /
    • 2011
  • This study is a research for analysis the states of flame resistant treatment and its system which important in fire prevention by ignition delay of early stage of fire. Some problems arose in the flame resistant treatment site were analysed through the meeting with fire officer and businessman related with flame resistant treatment, and visiting the flame resistant treatment places. From the meeting, visiting and reviewing the code system we find the following problems. First one is a problem of excessive competition with many company in small market of flame resistant treatment and to reduce the cost, the businessman who have no professional technic do not work along the specification. Second one is the inspection system which do not inspect on site but inspect by sampling the flame resistant treated materials submitted by businessman. And there are some problems arose about the reliability and consistency of flame resistant performance of the sample and the treated site. To solve the above problems, we suggest some countermeasure.

The Physical Properties of the Block Using Flame Resistant EPS Wastes (폐 난연성 EPS의 혼합조건에 따른 재생골재 블록의 물성에 관한 실험적 연구)

  • Cho, Kwang-Hyun;Kim, Ji-Hyun;Chung, Chul-Woo;Lee, Jae-Yong;Lee, Soo-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.152-153
    • /
    • 2013
  • Based on the Fire Service Act of mandatory provision, new buildings are strictly forced to use fire protection materials. Flame resistant EPS is one of those materials. Unlike conventional EPS that can be fused to make EPS ingot and be recycled for various purposes, flame resistant EPS waste cannot be recycled due to the presence of protective coating that is applied to increase the fire protection properties of EPS. A suitable alternative that can process large amount of flame resistant EPS wastes needs to be developed, and one of the possible alternative is to use them as construction materials. In this research, experiments were designed to observe whether the flame resistant EPS wastes can be utilized as partial replacements of fine aggregates in cement mortar. The replacement ratio of waste EPS was varied, and its effect on compressive strength and absorption capacity was investigated. According to the experimental results, both compressive strength and absorption capacity met the Korean Standard specification for cement bricks and blocks, indicating that flame resistant EPS wastes can be used for construction purposes.

  • PDF

A Study on the Flame Resistance Performance and Smoking Characteristics of the Flame-Resistant Paint (방염도료의 방염성능 및 발연특성에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.78-83
    • /
    • 2009
  • 17 kinds of fire resistant paint which are currently used were painted on the MDF, to find flame resistance performance and smoking characteristics according to principal ingredient and characteristics of fire resistant paint. 45 degree combustion test and smoke density test were conducted to investigate the flame resistance performance and smoking characteristics. According to the 45 degree combustion test, acrylic resin type fire resistant paint showed the most excellent fire resistance performance. And the water soluble fire resistant paint showed better fire resistance performance compare to the solvent soluble paints. Also gloss paint showed better fire resistance performance than the flat paint. Based on the smoke density test, the smoke generation of fire resistant treated specimen of acrylic resin type was least. And the water soluble fire resistant paint generate little smoke than solvent soluble fire resistant paint.

Effect of Flame Resistant Treatment on The Sound Absorption Capability of Sawdust-mandarin Peel Composite Particleboard (방염처리가 톱밥-귤박 혼합파티클보드의 흡음성능에 미치는 영향)

  • Kang, Chunwon;Jin, Taiquan;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.4
    • /
    • pp.511-517
    • /
    • 2015
  • Sound absorption capability of the flame resistant treated sawdust-mandarin peel composite particleboard was were estimated by two microphone transfer function methods. The weight of flame resistant treated board slightly increased by the treatment. The treatment improved fire retardant performance by decreasing the charred area of flame resistant treated board. Sound absorption capabilities of flame resistant treated sawdust-mandarin peel composite particleboard, in the entire estimated frequency range of 500-6,400 Hz was slightly lower than those of the control specimen. Sound absorption capability of both the control and flame resistant treated sawdust-mandarin peel composite particleboards were higher than that of commercial gypsum boards, being widely used as a sound absorber for ceiling at the estimated frequency.

A Study on the Combustion Characteristics of Wood According to Flame Resistant Treatment (방염처리 방법에 따른 목재의 연소특성 연구)

  • Park, Sung-Hyun;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.12-18
    • /
    • 2015
  • This study has conducted an experiment of comparing the flame resistant performance and combustion characteristics according to flame resistant treatment using the Cypress Luba and particle board that is commonly used for interior decoration and furniture. As a result of testing the flame resistant performance of Cypress Luba, the Cypress Luba injected with flame resistant resin using the vacuum pressure treatment has shown to have better performances (carbonized area 9.55% and carbonized length 22.91%) than the Cypress Luba treated with flame resistant coating having rubberized plastic components on its surface. For particle board, the specimen attached with fireproof film was identified to be better (carbonized area 40.10% and carbonized length 43.40%) than the specimen with non-fireproof film. For the results of combustion characteristics using the Cone Calorimeter, the specimen treated with flame resistant coating on the surface had faster ignition than the Cypress Luba injected with fire resistant resin using vacuum pressure treatment, and in the total release of calories, the Cypress Luba injected with fire resistant resin using vacuum pressure had $68.2MJ/m^2$, and the specimen treated with fire resistant coating on the surface had $111.52MJ/m^2$. For the particle board, the ignition time had a little difference but in the total release of calories, the specimen attached with fireproof film had $90.1MJ/m^2$ and the specimen with non-fireproof film had $107.6MJ/m^2$.

A Study on Fire Prevention Capability Performance Evaluation of the Phosphate Flame Retardant Honeycomb Core (인계 난연 허니컴 코아의 방화성능평가에 관한 연구)

  • Moon, Sung-Woong;Lim, Kyung-Bum;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.72-77
    • /
    • 2010
  • Honeycomb core structure with its excellent stiffness and strength is being utilized in many fields such as interior building material. Because it is inexpensive and renewable, honeycomb paper production is economically and environmentally helpful. However, the paper needs to be fireproofed because it is vulnerable to fire. In this study, we have undergone the performance evaluation process of the honeycomb paper which is widely used as interior material of a fire door and packing material. Four kinds of honeycomb (a honeycomb made of flame-resistant paper; a honeycomb attached with conventional flame-resistant film made in the laboratory; honeycomb impregnated with flame retardant; a honeycomb attached with flame-resistant film after impregnating fire retardant) were used in the study to compare the fire retardant performance. As a result, the honeycomb with impregnated flame retardant showed the highest performance. The flame-resistant film was effective in delaying the igniting time but had a negative effect on the rate of heat and smoke production.

A Study on Fire Prevention Requirements and Tests for Small Aircraft (소형항공기의 화재방지 요건 및 시험에 관한 연구)

  • Yoo, Seung-Woo;Jin, Young-Kwon
    • Journal of Aerospace System Engineering
    • /
    • v.5 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • The goal of fire prevention research is to eliminate fires as a cause of fatal accidents and there are two main areas of research. One is to prevent flame propagation during in-flight and it addresses fire hazards. The other is to minimize the possibility of flame penetration or fuselage burn-through and it aims toward post-crash survival include crash protection, emergency evacuation and post-evacuation survival. Civil aviation authorities world-wide are trying to identify threats and measure performance for fire prevention. The results of research are standardized and given as general directions of test methods. This paper has prepared to study and present the means of compliance to the fire prevention requirements and applicable test methods.