• Title/Summary/Keyword: flame

Search Result 4,209, Processing Time 0.033 seconds

Analysis of Trans Fatty Acid Content in Processed Foods and Meat Products (가공식품과 육가공품의 트랜스 지방산 함량 조사)

  • Park, Jung-Min;Ji, Won-Gu;Kim, Eun-Jung;Park, Da-Jung;Shin, Jin-Ho;Shim, Soon-Mi;Suh, Hyung-Joo;Chang, Un-Jae;Kang, Duk-Ho;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.27 no.4
    • /
    • pp.531-537
    • /
    • 2007
  • Small amounts of trans fatty acids exist naturally in beef and dairy foods. Also, they can be produced in the process of partial hydrogenation to manufacture shortning or margarine. They can provide a better palatability and shelf life. According to the recently studies, trans fatty acids can raise health risk such as heart diseases and coronary artery diseases. They can also increase low-density lipoprotein (LDL) cholesterol and decrease high-density lipoprotein (HDL) cholesterol in the blood plasma, therefore increasing the risk of atherosclerosis and diabetes. The aim of this study was to determine total lipids and trans fatty acids (TFAs) content in processed foods and meat products. The analysis of trans fatty acids was performed in 28 samples of donuts, 18 samples of bakeries, 4 samples of frozen doughs, 2 samples of popcorns, and 4 samples of meat products (ham, sausage, nuget, and bacon). Total lipids in processed foods and meat products were extracted by chloroform-Methanol method and acid digestion, respectively. They were analyzed by gas chromatography using a SP-2560 column and flame ionization detector. The amounts of TFAs per 100 g of foods were 0-3.3% (0.74% on average) in donuts, 0.2-5.8% (1.18% on average) in bakeries, 0.2-6.3% (1.93% on average) in frozen doughs, and 0-5.8% in popcorns. Meat products such as ham, sausage, and nuget analyzed 0.1% of TFAs, respectively and trans fatty acids in bacon were not detected. As a result, the distribution of TFAs in processed foods was widely ranged from O% to 6.3% according to manufacturers and types of products, whereas the content of TFAs in meat products ranged from 0% to 0.1%.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

A historical study of the Large Banner, a symbol of the military dignity of the Late Joseon Dynasty (조선 후기 무위(武威)의 상징 대기치(大旗幟) 고증)

  • JAE, Songhee;KIM, Youngsun
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.4
    • /
    • pp.152-173
    • /
    • 2021
  • The Large Banner was introduced during the Japanese Invasions of Korea with a new military system. It was a flag that controlled the movement of soldiers in military training. In addition, it was used in other ways, such as a symbol when receiving a king in a military camp, a flag raised on the front of a royal procession, at the reception and dispatch of envoys, and at a local official's procession. The Large Banner was recognized as a symbol of military dignity and training rites. The Large Banner was analyzed in the present study in the context of two different types of decorations. Type I includes chungdogi, gakgi and moongi. Type II includes grand, medium, and small obangi, geumgogi and pyomigi. Each type is decorated differently for each purpose. The size of the flag is estimated to be a square of over 4 ja long in length. Flame edges were attached to one side and run up and down The Large Banner used the Five Direction Colors based on the traditional principles of Yin-Yang and Five Elements. The pattern of the Large Banner is largely distinguished by four. The pattern of large obangi consists of divine beasts symbolizing the Five Directions and a Taoism amulet letter. The pattern of medium obangi features spiritual generals that escort the Five Directions. The pattern of small obangi has the Eight Trigrams. The pattern of moongi consists of a tiger with wings that keeps a tight watch on the army's doors. As for historical sources of coloring for Large Banner production, the color-written copy named Gije, from the collection of the Osaka Prefect Library, was confirmed as the style of the Yongho Camp in the mid to late 18th century, and it was also used for this essay and visualization work. We used Cloud-patterned Satin Damask as the background material for Large Banner production, to reveal the dignity of the military. The size of the 4 ja flag was determined to be 170 cm long and 145 cm wide, and the 5 ja flag was 200 cm long and 175 cm wide. The conversion formula used for this work was Youngjochuck (1 ja =30cm). In addition, the order of hierarchy in the Flag of the King was discovered within all flags of the late Joseon Dynasty. In the above historical study, the two types of Large Banner were visualized. The visualization considered the size of the flag, the decoration of the flagpole, and the patterns described in this essay to restore them to their original shape laid out the 18th century relics on the background. By presenting color, size, material patterns, and auxiliary items together, it was possible not only to produce 3D content, but also to produce real products.

Monitoring of Benzoic, Sorbic and Propionic Acid in Cereal Grains, Nuts and Seeds (곡류 및 견과 종실류 중 안식향산, 소브산, 프로피온산의 함유량 조사)

  • Yun, Sang Soon;Lee, Sang Jin;Lim, Do Yeon;Lim, Ho Soo;Lee, Gunyoung;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.65-72
    • /
    • 2019
  • This study was aimed at investigating the levels of the natural preservatives of benzoic, sorbic and propionic acids in cereal grains, nuts and seeds. Benzoic and sorbic acid were analyzed by high-performance liquid chromatography with a diode-array detector (HPLC-DAD) and further confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS), whereas propionic acid was analyzed using a gas chromatography-flame ionization detector (GC-FID) and further confirmed by gas chromatography-mass spectrometry (GC-MS). Benzoic, sorbic and propionic acids were found in 44, 22, and 550 samples out of 702 samples, respectively. From the total of 702 samples. The concentrations of benzoic, sorbic and propionic acid were ranged from not detected (ND) to 23.74 mg/L, from ND to 7.90 mg/L, and from ND to 37.39 mg/L in cereal grains, nuts and seeds, respectively. The concentration ranges determined in this study could be used as standard criteria in the process of inspecting cereal grains, nuts and seeds for preservatives as well as to address consumer complaints or trade disputes.

Four Heavenly Kings Statues of Hoeamsa in the Early Joseon Dynasty: Seen Through Clay-Fragments Excavated From the Yangju Hoeamsa Site (양주 회암사지(楊州 檜巖寺址) 4단지 문지 출토 소조편(塑造片)을 통해 본 회암사 사천왕상)

  • SHIM, Yeoungshin
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.3
    • /
    • pp.168-191
    • /
    • 2021
  • This article examines the shape, iconography, and creation date of the Four Buddhist Heavenly Kings (Sacheonwang 四天王) enshrined in the Heavenly Kings' Gate (Cheonwangmun 天王門) of Hoeamsa in Yangju, Gyeonggi Province during the early Joseon Dynasty. First, small fragments of clay decoration excavated from a fourth-platform gate site of the Hoeamsa Temple Site in Yangju Gyeonggi Province were analyzed and compared to other Four Heavenly Kings enshrined in the (Cheonwangmun gates) during the Joseon Dynasty. In addition, the size and shape of the gate were compared to other Cheonwangmun gates constructed during the Joseon Dynasty. Results revealed that the excavated fragments were part of the armor of Sacheonwang, and the clay-standing statues enshrined in the fourth-platform gate of Hoeamsa Temple would be proportional in size to those of Beopjusa Temple in Boeum, South Chungcheong Province. The flame-type pieces, which decorated the Heavenly King's crown in the Joseon Dynasty, and the rectangular-type pieces were not found in artifacts from the Goryeo Dynasty. Therefore, the Sacheonwang sculptures of the Hoeamsa Temple were likely made in the late 15th century in the early Joseon Dynasty. A detailed iconography of the Sacheonwang of Hoeamsa is presumedly based on the Buddhist paintings and illustrations of Buddhist scriptures (Gyeongbyeonsangdo 經變相圖)from the late Goryeo and early Joseon. During the late Goryeo Dynasty and early Joseon Dynasty, Traditional iconography from Goryeo and new iconography from Ming coexisted. However, in the late 15th century, the Sacheonwang statues of the early Joseon Dynasty had many different elements from those of the Goryeo Dynasty and were similar to those enshrined in Cheonwangmun Gate during the Joseon Dynasty. The Four Heavenly Kings of Hoeamsa Temple, believed to have been produced in the late 15th century, has historical significance in the following points. They were the first Joseon Sacheonwang statues example enshrined in the Cheonwangmun gate. In addition, they were established as a new tradition that influenced the iconography of the Four Heavenly Kings during the Joseon Dynasty.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Studies on Press Drying of Fire-Retardant Treated Plywood (내화처리합판(耐火處理合板)의 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Kim, Jong Man
    • Journal of Korean Society of Forest Science
    • /
    • v.56 no.1
    • /
    • pp.1-25
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable and can cause fire accidents. causing destruction of human life and property. To diminish the fire disaster, fire retardant plywood is indeed required. In the methods of manufacturing the fire retardant plywood, a soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions redrying of soaked plywood is of the utmost importance. In this study 3.5mm and 5.0mm thickness plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid minalith, and water solution, 1-, 3-, 6-, and 9 hour-soaking treatments in borax-boric acid and minalith, and 6- and 9 hours in the other chemicals were applied and after the treatment hot drying was applied to treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$ of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1) In the 9 hours-soaking treatment of fire retardants by hot and cold bath method, the chemical retentions of 3.5mm thickness plywood could be attained within the range ($1.125-2.25kg/(30cm)^3$) of minimum retention specification as follows: $1.353kg/(30cm)^3$ in monoammonium phosphate, $1.331kg/(30cm)^3$ in diammonium phosphate, $1.263kg/(30cm)^3$ in ammonium sulfate, $1.226kg/(30cm)^3$ in borax-boric acid. But the chemical retention, $0.906kg/(30cm)^3$, in minalith could not be attained within the range of minimum retention specification. And also in case of 5.0mm thickness plywood, chemical retentions, as $1.356kg/(30cm)^3$ and $1.166kg/(30cm)^3$ respectively, of ammonium sulfate and diammonium phosphate could be attained within the range minimum retention specification, but the other fire retardant chemicals could not. 2) In the 6- and - hours-soaking treatments of 3.5mm and 5.0mm thickness plywood, the drying curve sloped of chemical treated plywood was smaller than that of water treated. The drying rate related to thickness of treated plywood, was about three times as fast in 3.5mm thickness plywood compared with 5.0mm thickness plywood. 3) In the treatment at $120^{\circ}C$ of hot platen temperature, the drying rates of chemical-treated plywood showed the highest quantity in diammonium phosphate of 3.5mm and 5.0mm thickness plywood. But the drying rate of water treated plywood was highest during the 6- and 9 hours-soaking treatments. 4) The drying rate remarkably increased with proportion to increase of the platen temperature, and the values were respectively 1.23%/min., 6.54%/min., 25.75%/min. in hot platen temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in 3.5mm thickness plywood and 0.55%.min., 2.49%/min., 8.19%/min. in hot platen temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in 5.0mm thickness plywood. 5) In the fire retardant degree of chemical treated plywood, the loss in weight was the smallest in diammonium phosphate, next was in monoammonium phosphate and ammonium sulfate, and the greatest was in borax-boric acid and minalith. And the fire-retardant effect in burning time, flame-exhausted time and carbonized area were greatest in diammouniun phosphate, next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric acid and minalith.

  • PDF

Studies on the Life History of Bacciger harengulae (Bacciger harengulae의 생활사에 관한 연구)

  • KIM Young-Gill;CHUN Seh-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.5
    • /
    • pp.449-470
    • /
    • 1984
  • The cercaria of Bacciger herengulae which is parasitized on the gonad of Solen strictus was investigated in order to reveal its entire life history. The area covered for the study was in the vicinity sea of Naechodo, the estuary of the Kum river in the western coast of Korea during the period of 1980-1983. Morphology and development as well as infection rates of sporocyst and cercaria within Solen strictus were examined. For accomplishing the objectives of this study, an artificial infection experiment and some investigations on the second intermediate host, the final host and the growing stages were also studied in both laboratory and natural habitat of Solen strictus. According to the study, it was revealed that the first intermediate hosts were Meretrix lusoria, Solen strictus, Tapes japonica and Laternula limicola, the second intermediate host was Palaemon (Exopalaemon) carinicauda and the final hosts were Konosirus punctatus and Harengula zunasi. A mature sporocyst which was found in the gonad of Solen strictus was $4.0-4.3{\times}0.2-0.21\;mm$ insize, and the cercaia with 27 pairs of setae, each seta consisting of 6 tufts, was $270{\times}147{\mu}m$ in body size and $550{\times}52{\mu}m$ in tail size. Oral sucker($52{\times}42{\mu}m$), pharynx, vental sucker and two testese were obviously seen within the cercaria. The excretory vesicles of cercaria were in V-shape and the flame cell were formula was expressed as 2[(3+3)+(3+3)]=24. The infection of cercaria in the first intermediate host, Solen strictus, was found throughout the year regardlless of the water temperature, and its mean infection rate was $9.67\%$ during the study period. The infection rate fluctuated with temperature, the highest being $28.0\%\;at\;28.0^{\circ}C$ water temperature in July and the lowest $2.4\%\;at\;19.5^{\circ}C$ in October, and it increased in proportion to the shell length on the host. But cercaria was not detected at below 4.0 cm in size of the host. Mature cercariae were found 6 months from May to October when water temperature was above $19.5^{\circ}C$. On the other hand, when water temperature was below $19.5^{\circ}C$, only immature cercariae and sporocysts were found. The cercariae were active for 35 hours and survived for 71 hours at $20^{\circ}C$, and 29 and 34 hours at $25^{\circ}C$ respectively, whereas the cercariae were inactive at less than $20^{\circ}C$ in water temperature. Cercaria, from Solen strictus, approached shrimp of 1-3 cm in body length as its second host. Then, it began to intrude in to the muscle of shrimp after 2-3 hours. The infected cercaria formed cyst after 7-8 hours, and became mature metacercaria. $420{\times}310{\mu}m$ in size, 15 days afer infection. The infection rate of metaceria to shrimp in the laboratory was highest, at $25^{\circ}C$ being $61\%$ and at $20^{\circ}C\;17%$. The infection rate of metacearia in shrimp was highest in the first abdominal segment, followed by cephalothorax, the second, and fifth abdominal segments, and in that order. Also, the infection rate of metacercaria in wild shrimp was high $9.6-11.1\%$ at $26.5^{\circ}C$ in June, and low $1.56-2.5\%$ at $28-29.5^{\circ}C$ from July to August. The infected shrimp with metacercaria was experimentally fed to Konosirus punctatus in the laboratory in order to know its final host. The metacercaria developed into the adult worm, $440-520{\times}310-360{\mu}m$ in size, within the intestine of Konosirus punctatus 20 days after infection. The adult worm was oval shape and $20-24{\times}11-20{\mu}m$ in size. The infection rate of adult worm to Konosirus punctatus and Harengula zunasi ranged 87.3 to $100\%$, the mean being $95.2\%$, regardless of the body length of their hosts. The infection rate was $100\%$ in June and July, but it decreased in September and October. The size and body structure of the trematode observed during the present study were well agreed with those ievestigated by Yamaguti(1938), thus, it may be concluded that the adult worm it identified as Bacciger harengulae.

  • PDF

Studies on Fire-Retardant-Treatment and Press Drying of Plywood (합판(合板)의 내화처리(耐火處理)와 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.5-37
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable to bring large fire accidents and burn out human life and their properties. To diminish the fire disaster, fire retardant plywood has been required indeed. In the methods of manufacturing the fire retardant plywood the soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions, redrying of soaked plywood is the most important. In this study, 3.5mm thin and 5.0mm thick plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid and minalith, and water solution. 1-, 3-, 6-, and 9 hour-soaking treatments were applied and after treatments hot plate drying was applied to those treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$, of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1. The plywoods treated with ammonium sulfate, monoammonium phosphate and diammonium phosphate and diammonium phosphate showed increase of chemical absorption rate with proportion to increase of treating time, but not in case of the plywood treated with borax-boric acid and minalith. 2. In the treatment of definite time, the absorption rate per unit of volume of plywood showed higher in thin plywood (thickness of 3.5mm) than in thick plywood (thickness of 5.0mm). In both thin and thick plywoods, the highest absorption rate was observed in 9 hour-treatment of ammonium sulfate. The value was 1.353kg/$(30cm)^3$ in thin plywood and 1.356kg/$(30cm)^3$ in thick plywood. 3. The volume per weight of plywood after chemical treatment increased remarkably and. after hot plate drying, the values were to a little extent higher than before chemical treatment. 4. The swelling rates of thickness in chemical-treated plywoods increased similarly with that of water-treated plywood in 1- and 3 hour-treatment of both thin and thick plywoods. But in 6- and 9 hour-treatment, the greater increased value showed in water-treated ply wood than any other chemical, especially in thick plywood. 5. The shrinkage rates after hot plate drying showed the same tendency as the swelling rate, and the rate showed the increasing tendency with proportion to increase of treating time in thick plywood of both chemical and water treatments. 6. Among drying curves, the curves of water-treated plywood placed more highly than chemical-treated plywood without-relation to thickness in 6- and 9 hour-treatment except in 1- and 3 hour-treatment. 7. The drying rate related to thickness of treated plywood, was twice above in thin plywood compared with thick plywood. 8. The drying rate remarkably increased with proportion to increase of the plate temperature and, the values were respectively 1.226%/min., 6.540%/min., 25.752%/min. in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thin plywood and 0.550%/min., 2.490%/min, 8.187%/min, in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thick plywood. 9. In the treatment at $120^{\circ}C$ of hot plate temperature, the drying rates of chemical-treated plywood showed the highest value in monoammonium phosphate of thin plywood and in diammonium phosphate of thick plywood. But the drying rate of water-treated plywood was highest in 6- and 9 hour-treatment. 10. The fire retardant degree of chemical-treated plywood was higher than that of the untreated plywood as shown in loss of weight, burning time, flame-exhausted time and carbonized area. 11. The fire-retardant effect among fire retardant chemicals were the greatest in diammonium phosphate, the next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric and minalith.

  • PDF