• 제목/요약/키워드: fixtures

검색결과 384건 처리시간 0.028초

임플란트 고정체의 나사산 형태와 하중조건에 따른 응력분석 (Finite Element Stress Analysis of the Implant Fixture According to the Thread Configuration and the Loading Condition)

  • 안옥주;정제옥;김창현;강동완
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.153-167
    • /
    • 2005
  • The purpose of this study was to compare the v-shape thread with the square shape thread of fixture in the view of stress distribution pattern using finite element stress analysis. The finite element model was designed with the parallel placement of two standard fixtures(4.0 mm diameter ${\times}$ 11.5 mm length) on the region of mandibular 1st and 2nd molars. Three dimensional finite element model was created with the components of the implant and surrounding bone. This study simulated loads of 200 N at the central fossa in a axial direction (load A), 200 N at the buccal offset load that is 2 mm apart from central fossa in a axial direction (load B), 200 N at the buccal offset load that was 4 mm apart from central fossa in a axial direction (load C). These forces of load A',B',C' were applied to a $15^{\circ}$ inward oblique direction at that same site with 200 N. Von Mises stress values were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study : 1. The highest stress concentration occurred at the cervical region of the implant fixture. 2. Von Mises stress value of off-site region was higher than that of central fossa region. 3. Square shape thread type showed more even stress distribution in the vertical and oblique force than V-shape thread type. 4. Stress distribution was the most effective in the case of buccal offset load (2, 4 mm distance from central fossa) in the square shape thread type. 5. V-shape thread type revealed higher von Mises stress value than square shape thread type in all environmental condition. The results from numerical analyses concluded that square shape thread type had the lower destructive stress and more stress distribution between the fixture and bone interface than V-shape thread type. Therefore, square shape thread type was regarded as optimal thread configuration in biomechanical concepts.

치조골 높이가 다른 2개 임플란트 금관의 고정연결 조건에 따른 응력분석 (Stress Analysis on the Splinted Conditions of the Two Implant Crowns with the Different Vertical Bone Level)

  • 전창식;정신영;강동완
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.169-182
    • /
    • 2005
  • The purpose of this study was to compare the stress distribution around the surrounding bone according to the splinted and non-splinted conditions on the finite element models of the two implant crowns with the different vertical bone level. The finite element model was designed with the parallel placement of the two fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st and 2nd molars. As the bone quality, the inner cancellous bone and the outer 2 mm cortical bone were designed, and the cortical and cancellous bone were assumed to be perfectly bonded to the implant fixture. The splinted model(Model 1) had 2 mm contact surface and the non-splinted model(Model 2) had $8{\mu}m$ gap between two implant crowns. Two group (Splinted and non-splinted) was loaded with 200 N magnitude in the vertical and oblique directions on the loading point position on the central position of the crown, the 2 mm and 4 mm buccal offset point from the central position. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual and mesio-distal sections. The results were as follows; 1. In the vertical loading condition of central position, the stress was distributed on the cortical bone and the cancellous bone around the thread of the fixture in the splinted and non-splinted models. In the oblique loading condition, the stress was concentrated toward the cortical bone of the fixture neck, and the neck portion of 2nd molar in the non-splinted model was concentrated higher than that of 1st molar compared to the splinted model. 2. In the 2 mm buccal offset position of the vertical loading compared to the central vertical loading, stress pattern was shifted from apical third portion of the fixture to upper third portion of that. In the oblique loading condition, the stress was distributed over the fixture-bone interface. 3. In the 4 mm buccal offset position of the vertical loading, stress pattern was concentrated on the cortical bone around the buccal side of the fixture thread and shifted from apical third portion of the fixture to upper third portion of that in the splinted and non-splinted models. In the oblique loading, stresses pattern was distributed to the outer position of the neck portion of the fixture thread on the mesio-distal section in the splinted and non-splinted models. Above the results, it was concluded that the direction of loading condition was a key factor to effect the pattern and magnitude of stress over the surrounding bone of the fixture under the vertical and oblique loading conditions, although the type with or without proximal contact did not effect to the stress distribution.

구개측 미니플래이트를 이용한 양악 치아치조성 전돌환자에서의 설측 Biocreative therapy 적용 (Severe bidentoalveolar protrusion treated with lingual Biocreative therapy using palatal miniplate)

  • 정규림;정도민;박현정;김성훈
    • 대한치과교정학회지
    • /
    • 제40권4호
    • /
    • pp.276-287
    • /
    • 2010
  • 본 증례보고는 심한 양악 치아치조성 전돌과 전치부 치열밀집을 보이는 23세 8개월 여자 환자를 대상으로 한 변형된 형태의 설측 교정치료법인 설측 Biocreative therapy 치료를 소개하고자 한다. 양악 제1소구치 발치 후 구개천장에 식립된 C-플래이트에 lingual sheath가 달린 보조장치를 접착하여 상악구치부에 장치부착 없이 튜브역할을 대신하게 하였으며 상악 전치부의 decrowding과 견인을 위하여 설측 교정용 브라켓을 사용하지 않고 0.022 슬롯을 가진 순측 브라켓을 치아 설면에 부착한 후 납착된 설측 레버암을 이용하여 상악 전치부의 3차원적인 견인을 시행하였으며, 견인 후 finishing 기간동안 tooth positioner를 사용하였다. 상악 구치부의 장치부착 없이도 총 치료기간은 19개월 소요되었고, 안정적인 교합관계와 안모의 개선이 이루어졌다. 장치 제거 후 13개월 유지 후에도 양호한 결과가 유지되었다.

주광(晝光) 대등형 가변조명(可變照明) 제어설비의 적용 및 통합성능 (Energy Efficient Lighting Control Facilities Related to Daylight Levels)

  • 김정태;김곤
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.8-15
    • /
    • 2006
  • 에너지 절약형 광원의 대체와 아울러 최적 운용 기술의 개발만이 건축조명부분에 대한 에너지 절약의 잠재력을 현실화 시킬 수 있다고 판단된다. 광원의 효율을 향상시키는 것은 기술적인 한계와 많은 개발시간이 요구되는 반면에 조명제어의 최적화 기술은 많은 기술이 개발되어 사용되고 있는 상황이므로, 보다 지능적이고 복합적인 시스템 차원에서 효율을 높이기 위한 노력들이 이루어지고 있다. 특히 상업용 건물이나 사무소건물에 있어 고효율 형광등과 전자식 안정기의 도입이후에 에너지 절감방안의 대표적인 것은 조명제어라고 인식하고 있다. 본 연구에서 분석한 일반적인 사무소 공간의 경우, 주광과 인공조명을 통합제어할 때 담천공 조건에서 소등할 수 있는 주광의 유효 입사 거리는 창측에서 약 4[m]에서부터, 시간대에 따라 5[m]에 이르는 것으로 나타났다. 이는 실내에 설치된 인공 조명기구의 약 60[%] 이상이 소등될 수 있어 동일한 비율의 조명 에너지가 절감될 수 있는 잠재력을 나타낸다. 입사각과 태양광량의 상호 보완적 특성으로 인하여 주간 내내 일정한 주광의 유효거리가 확보되는 것으로 나타났다. 계절별 소등라인축의 이동범위는 실내에서 자연의 변화를 느끼게 해주는 정도의 바람직한 것으로 허용될 수 있을 것이며, 자연광에 가까운 광색을 가진 광원을 사용함으로써 쾌적한 조명을 유지할 수 있을 것이다.

감성조명용 조명기기의 조도 및 색온도 시뮬레이션을 통한 광원 조합의 최적화 (Optimization of Light Source Combination through the Illuminance and Color Temperature Simulation of Circadian Lighting Apparatus)

  • 박양재;최종현;장명기
    • 한국콘텐츠학회논문지
    • /
    • 제9권8호
    • /
    • pp.248-254
    • /
    • 2009
  • 본 연구의 목적은 감성조명용 조명기기의 조도 및 색온도 표현 능력을 극대화할 수 있는 최적의 광원조합을 도출하는데 있다. 이를 위하여 감성조명용 조명기기는 2000K와 8000K의 서로 다른 색온도를 가지는 형광램프로 구성하였으며, 각각의 형광램프의 조합 수량을 변화시키며 조명기기의 조도 및 색온도 표현 능력을 광학 simulation을 통해 평가하였다. 이 때, Kruithof's curve 및 예외 경우를 고려하여 실내 활동종류에 따른 조도 및 색온도 영역을 가족모임, 학습, 휴식, 수면 등의 4가지로 다시 구분하였으며, 이를 통해 감성조명용 조명기기의 조도 및 색온도 구현범위에 대한 목표치를 설정하였다. 평가 결과, 2000K와 8000K의 색온도를 가지는 형광램프를 각각 4개와 5개씩 채용한 조명기기 2 개를 조합하는 경우 4000K에서 최대 밝기를 보이며 3000K와 6000K에서도 500lx 이상의 밝기를 구현할 수 있는 것으로 예측 되었다. 본 연구에서 최적화 된 광원 조합을 통해 구현할 수 있는 조도 범위는 $44{\sim}750lx$ 이며 유효 색온도 범위는 $2500\;{\sim}\;6500K$인 것으로 예측되었다.

도축장의 생.해체검사를 통한 경산우 및 미경산우 감별법(II) (Discrimination of cows from heifers by antemortem and postmortem inspection in slaughterhouses (II))

  • 최임용;최태석;이달주;이해영;김연하;이경혜;노창식;김규현;김은;신방우;이정학
    • 한국동물위생학회지
    • /
    • 제31권3호
    • /
    • pp.375-384
    • /
    • 2008
  • This study was performed to establish the discrimination of the corpus albicans that were formed after normal parturition and abortion in Holstein, The corpus albicans were obtained from 504 cows and 506 heifers slaughtered in the Agricultural Cooperative's Livestock Products Joint Market of Seoul City from March 2007 to October 2007. The difference in a gross examination (morphology, fibrogenesis, deposit state, color, and size) among the fixtures that exist in their ovaries was investigated. All of the cows had corpus albicans in their ovaries: 423 cows (83.9%) had less than three corpus albicans, 81 (16.1%) had more than four. In the heifers, however, 463 (91.05%) had no corpus albicans, 39 (7.7%) had one, and four (0.8%) had more than two. In the types of corpus albicans 73.2% of the cows had oval-type, 14.4% had circular-shaped, 12.4% had irregular-type. In the aborted heifers, however, oval-type appeared in 88.6% and circular-shaped appeared in 11.4%, and no irregular-type was found. There was no significant difference in the fibrogenesis and size of corpus albicans between cows and aborted heifers. However, slight difference in the color of the corpus albicans was observed between two types. In conclusion, it is not easy to discriminate by gross examination of ovary between cows and aborted heifers in the slaughter house.

분층피부와 분말골로 이식 전 처리된 유리견갑골근피판과 임플란트 보철을 이용한 경구개와 상악골의 기능적 재건 (FUNCTIONAL RECONSTRUCTION OF DENTO-PALATAL AND MAXILLARY DEFECT USING STAGED OPERATION OF PREFABRICATED SCAPULAR FREE FLAP AND DENTAL IMPLANTS)

  • 이종호;김명진;박종철;김영수;안강민;팽준영;김성민;명훈;황순정;서병무;최진영;정필훈
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.301-307
    • /
    • 2004
  • The flap considered at first for the reconstruction of large maxillary defect, especially mid-face defect, is scapular free flap, because it provides ample composite tissue which can be designed 3-dimensionally for orbital, facial and oral reconstruction. In case of maxillary defect involving hard palate, however, this flap has some limitations. First, its bulk prevents oral function and physio-anatomic reconstruction of nasal and oral cavity. Second, mobility and thickness of cutaneous paddle covering the alveolar area reduce retention of tissue-supported denture and give rise to peri-implantitis when implant is installed. Third, lateral border of scapula that is to reconstruct maxillary arch and hold implants is straight, not U-shaped maxillary arch form. To overcome these problems, new concept of step prefabrication technique was provided to a 27-year-old male patient who had been suffering from a complete hard palate and maxillary alveolar ridge defect. In the first stage, scapular osteomuscular flap was elevated, tailored to fit the maxillary defect, particulated autologous bone was placed subperiosteally to simulate U-shaped alveolar process, and then wrapped up with split thickness skin graft(STSG, 0.3mm thickness). Two months later, thus prefabricated new flap was elevated and microtransferred to the palato-maxillary defect. After 6 months, 10 implant fixtures were installed along the reconstructed maxillary alveolus, with following final prosthetic rehabilitation. The procedure was very successful and patient is enjoying normal rigid diet and speech.

Accuracy of several implant bite registration techniques: an in-vitro pilot study

  • Park, Do-Hyun;Park, Ji-Man;Choi, Jae-Won;Kang, Eun-Sook;Bae, Eun-Bin;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.341-349
    • /
    • 2017
  • PURPOSE. This study evaluated the accuracies of different bite registration techniques for implant-fixed prostheses using three dimensional file analysis. MATERIALS AND METHODS. Implant fixtures were placed on the mandibular right second premolar, and the first and second molar in a polyurethane model. Aluwax (A), Pattern Resin (P), and Blu-Mousse (B) were used as the bite registration materials on the healing abutments (H) or temporary abutments (T). The groups were classified into HA, HP, HB, TA, TP, and TB according to each combination. The group using the bite impression coping was the BC group; impression taking and bite registration were performed simultaneously. After impression and bite taking, the scan bodies were connected to the lab analogs of the casts. These casts were scanned using a model scanner. The distances between two reference points in three-dimensional files were measured in each group. One-way ANOVA and Duncan's test were used at the 5% significance level. RESULTS. The smallest distance discrepancy was observed in the TB group using the temporary abutments. The Blu-Mousse and HP groups showed the largest distance discrepancy. The TB and BC groups showed a lower distance discrepancy than the HP group (P=.001), and there was no significant difference between the groups using the temporary abutments and healing abutments (P>.05). CONCLUSION. Although this study has limitations as an in-vitro investigation, the groups using the temporary abutments to hold the Blu-Mousse record and bite impression coping showed greater accuracy than the group using the healing abutments to hold the pattern resin record.

유니버셜 디자인 된 욕실설비에 대한 미국/한국 노인소비자 견해 (An American/Korean Older Consumers' Perceptions of Universally Designed Bathing Fixtures)

  • Shin, Kyoung-Joo;White, Betty-Jo
    • 한국주거학회논문집
    • /
    • 제11권2호
    • /
    • pp.149-163
    • /
    • 2000
  • 노인소비자들은 나이와 함께 기능적인 능력이 감퇴하면서 주택내의 환경이 그들의 한계와 장애를 보완해 줄 수 있게 좀 더 지원적이기를 기대한다. 이러한 노인그룹을 포함하여 모든 사용자에게 독립적이고, 안전하며, 편리한 생활환경을 조성해 주는 것이 유니버셜 디자인이다. 이 연구의 목적은 유니버셜 디자인 개념으로 개발 된 혁신적인 욕실용품들, 즉 높이가 조절되어 앉거나 서서 사용하는 장점 등을 갖춘 세면대와 높이조절이 되는 이동식 샤워기가 장착된 걸어서 들어가며, 접이식 의자가 있는 등의 장점을 가진 욕조에 대한 소비자 의견의 검토이다. 피험자는 미국에 사는 미국노인과 한국노인(50세이상-79세까지)으로 합계 58명이었다. 실험장소는 미국서부소도시 대학의 유니버셜 디자인 연구실로, 이 대학의 협력으로 이곳에 장착된 신개발 설비를 이용하였다. 실험시기는 1997년 5월부터 11월 사이(봄, 가을)로 소비자 의견조사는 3단계로 이루어졌다. 먼저 1단계 설문조사에서는 피험자 거주주택의 욕실환경, 피험자의 목욕방법, 건강과 안전, 새로운 욕실설비에 대한 소비자 의견 등이 조사되었다. 2단계는 실제로 선정 된 욕실설비의 사용실험으로 피험자가 옷입은 상태에서 목욕을 가정하여 선택된 설비의 사용동작을 하면서(비디오 촬영) 조사자의 조사표에 의한 질문에 답하였다. 3단게는 2단계의 사용실험 후 유니버셜 디자인 된 욕실설비의 가정 내 도입의사 등의 조사를 하였다. 위에서 설명한 3단계의 소비자 의견조사 및 실험에서 얻은 결과는 다음과 같았다. 1) 미국거주 미국노인과 한국노인의 비교에서 한국노인의 평균 신장이 3cm정도 작았고, 2개이상의 욕실을 가진 비율과 학벌, 독신거주비율은 미국노인이 다소 높았고, 욕조 소유율은 한국노인이 높았다. 2) 새로운 욕실 설비에 대한 소비자 의견은 미국과 한국노인 모두 유니버셜 디자인된 새 설비의 장점을 인정하였다. 욕조와 세면조가 매력적이라 평하였고 샤워조작기가 색상구분으로 도운물과 찬물인지가 편하며, 접이식 의자가 유용하며, 문 달린 욕조의 안전 손잡이와 욕조가장자리를 잡고 안전하게 출입한다고 했다. 그러나 욕조길이와 높이에서 두 나라간에 차가 있어 앞으로 치수에 대한 것이 연구과제로 지적되었다. 3) 욕실 설비 개발 시 유니버셜 디자인 용품에 요구되는 목표는 안전하게 쓸 수 있고, 가령에 따른 신체장애요소가 커버되어 스스로 사용가능하고, 사용상 번거로움이 없어 정신적 스트레스를 주지않는 것이어야 하겠다. 4) 선택된 유니버셜 디자인 욕실설비는 표준치수의 현 욕조위치에 장착이 가능하여 앞으로 현 주택에의 교체가 가능하였다. 5) 선택된 유니버셜 디자인 욕실설비는 인체치수와 문화가 다른 두 나라 노인 모두 긍정적으로 평가하여 앞으로의 국제적 보급이 기대되었다.

  • PDF

하악 구치부에서 임플란트 고정체와 지대주의 협설 기울기에 따른 응력분포에 관한 삼차원 유한요소 분석 (Three Dimensional Finite Element Analysis on Stress Distribution According to the Bucco-lingual Inclination of the Implant Fixture and Abutment in the Mandibular Posterior Region)

  • 이현숙;김지연;김예미;김명래;김선종
    • 구강회복응용과학지
    • /
    • 제27권4호
    • /
    • pp.371-392
    • /
    • 2011
  • 본 연구는 임플란트의 지대주와 고정체의 식립 기울기 변화에 따른 교합력의 응력 분산을 비교 분석하고자 하였다. 치아 장축에 평행하게 식립한 임플란트 위에 직선적 지대주를 체결한 것을 기준 모델로 하여, $15^{\circ}$, $25^{\circ}$ 설측 경사진 지대주를 체결한 모델 2종류, 고정체를 $15^{\circ}$, $25^{\circ}$ 설측 경사 식립 후 동일 각도의 협측 경사의 지대주를 체결한 모델 2종류, 총 5개의 연구 모델에 각각 수직하중과 경사하중을 부가하여 나타난 응력분포를 3차원 유한요소법(finite element analysis)를 이용하여 분석하였다. 연구 결과, 지대주와 고정체의 식립 기울기가 증가할수록 복합하중에서 임플란트와 주위조직의 응력은 증가하였다. 다만 하중의 위치와 종류에 따라 응력의 변화가 모델에 따라 부분적으로 다르게 나타나기도 했다. 이는 응력이 하중의 작용선과 임플란트 고정체의 중심선과의 거리인 수평적 편심부하(horizontal offset)가 변화한 결과이며, 편심부하가 증가할수록 응력도 증가하는 결과를 보였다.