Finite element analysis of stress distribution on supporting bone of cement retained implant by loading location (하중 위치에 따른 시멘트 유지형 임플란트 지지골의 유한요소법 응력 분석)

  • Kim, Kap-Jin
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.143-149
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate the effect of two different oblique mechanical loading to occlusal surfaces of cement retained implant on the stress distributions in surrounding bone, using 3-dimensional finite element method. Methods: A 3-dimensional finite element model of a cement retained implant composed of three unit implants, simplified ceramic crown and supporting bone was developed according to the design of ement retained implant for this study. two kinds of surface distributed oblique loads(100 N) are applied to following occlusal surfaces in the single crowns; 1) oblique load on 2 occlusal points(50N for each buccal cusp, 2 buccal cusps exist), 2) oblique load on 4 occlusal points(25N for each buccal and lingual cusp, 2 buccal and 2 lingual cusps exist) Results: The results of the comparison of the stress distributions on surrounding bone are as follows. In the condition of oblique load on 2 occlusal points, VMS was 741.3 Mpa in the M1(Ø$4.0{\times}13mm$) model and 251.2 Mpa in the M2(Ø$5.0{\times}13mm$) model. It means the stress on the supporting bone is decreased. The results of oblique load on 4 occlusal points are similar to this one. Conclusion: Increasing the diameter of the implant fixture is helpful to distribute the stress on the supporting bone. Also, to obtain the structural stability of the supporting bone, it is effective to distribute the load evenly on the occlusal surface of crown in producing single crown implant.

A comparative study on the fit and screw joint stability of ready-made abutment and CAD-CAM custom-made abutment (기성 지대주와 맞춤형 CAD-CAM 지대주의 적합 및 나사 안정성 비교)

  • Kim, Jong-Wook;Heo, Yu-Ri;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.276-283
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the fit and screw joint stability between Ready-made abutment and CAD-CAM custom-made abutment. Materials and methods: Osstem implant system was used. Ready-made abutment (Transfer abutment, Osstem Implant Co. Ltd, Busan, Korea), CAD-CAM custom-made abutment (CustomFit abutment, Osstem Implant Co. Ltd, Busan, Korea) and domestically manufactured CAD-CAM custom-made abutment (Myplant, Raphabio Co., Seoul, Korea) were fabricated five each and screws were provided by each company. Fixture and abutments were tightening with 30Ncm according to the manufacturer's instruction and then preloding reverse torque values were measured 3 times repeatedly. Kruskal-Wallis test was used for statistical analysis of the preloading reverse torque values (${\alpha}=.05$). After specimens were embedded into epoxy resin, wet cutting and polishing was performed and FE-SEM imaging was performed, on the contact interface. Results: The pre-loading reverse torque values were $26.0{\pm}0.30Ncm$ (ready-made abutment; Transfer abutment) and $26.3{\pm}0.32Ncm$ (CAD-CAM custom-made abutment; CustomFit abutment) and $24.7{\pm}0.67Ncm$ (CAD-CAM custom-made abutment; Myplant). The domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) presented lower pre-loading reverse torque value with statistically significant difference than that of the ready-made abutment (Transfer abutment) and CAD-CAM custom-made abutment (CustomFit abutment) manufactured from the same company (P=.027) and showed marginal gap in the fixture-abutment interface. Conclusion: Within the limitation of the present in-vitro study, in domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) showed lower screw joint stability and fitness between fixture and abutment.

PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION (하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석)

  • Cho Hye-Won;Kim Nan-Young;Kim Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.

Survival analysis of dental implants in maxillary and mandibular molar regions; A 4$\sim$5 year report ($\cdot$하악 대구치 부위에 식립된 임플란트의 생존율에 대한 후향적 연구)

  • Jang, Jin-Wha;Ryoo, Gyeong-Ho;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.165-180
    • /
    • 2007
  • Dental Implants have been proved to be successful prosthetic modality in edentulous patients for 10 years. However, there are few reports on the survival of implant according to location in molar regions. The purpose of this study was to evaluate the $4{\sim}5$ years' cumulative survival rate and the cause of failure of dental implants in different locations for maxillary and mandibular molars. Among the implants placed in molar regions in Gwangju Mir Dental Hospital from Jan. 2001 to Jun. 2002, 473 implants from 166 patients(age range; $26{\sim}75$) were followed and evaluated retrospectively for the causes of failure. We included 417 implants in 126 periodontally compromised patients, 56 implants in 40 periodontal healthy patients, and 205 maxillary and 268 mandibular molar implants. Implant survival rates by various subject factors, surgical factors, fixture factors, and prosthetic factors at each location were compared using Chi-square test and Kaplan-Meier cumulative survival analysis was done for follow-up(FU) periods. The overall failure rate at 5 years was 1O.2%(subject level) and 5.5%(implant level). The overall survival rates of implants during the FU periods were 94.5% with 91.3% in maxillary first molar, 91.1% in maxillary second molar, 99.2% in mandibular first molar and 94,8% in mandibular second molar regions. The survival rates differed significantly between both jaws and among different implant locations(p<0.05), whereas the survival rates of functionally loaded implants were similar in different locations. The survival rates were not different according to gender, age, previous periodontal status, surgery stage, bone graft type, or the prosthetic type. The overall survival rate was low in dental implant of too wide diameter(${\geq}5.75$ mm) and the survival rate was significantly lower for wider implant diameter(p

A torque-measuring micromotor provides operator independent measurements marking four different density areas in maxillae

  • Di Stefano, Danilo Alessio;Arosio, Paolo;Piattelli, Adriano;Perrotti, Vittoria;Iezzi, Giovanna
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.51-55
    • /
    • 2015
  • PURPOSE. Bone density at implant placement site is a key factor to obtain the primary stability of the fixture, which, in turn, is a prognostic factor for osseointegration and long-term success of an implant supported rehabilitation. Recently, an implant motor with a bone density measurement probe has been introduced. The aim of the present study was to test the objectiveness of the bone densities registered by the implant motor regardless of the operator performing them. MATERIALS AND METHODS. A total of 3704 bone density measurements, performed by means of the implant motor, were registered by 39 operators at different implant sites during routine activity. Bone density measurements were grouped according to their distribution across the jaws. Specifically, four different areas were distinguished: a pre-antral (between teeth from first right maxillary premolar to first left maxillary premolar) and a sub-antral (more distally) zone in the maxilla, and an interforaminal (between and including teeth from first left mandibular premolar to first right mandibular premolar) and a retroforaminal (more distally) zone in the lower one. A statistical comparison was performed to check the inter-operators variability of the collected data. RESULTS. The device produced consistent and operator-independent bone density values at each tooth position, showing a reliable bone-density measurement. CONCLUSION. The implant motor demonstrated to be a helpful tool to properly plan implant placement and loading irrespective of the operator using it.

Retrospective study of conical connection dental implant (Ankylos dental Implant). (Conical connection 임프란트(Ankylos dental implant)에 대한 후향적 임상연구)

  • Yang, Byoung-Eun;Song, Sang-Hun;Shim, Hye-Won;Lee, Sang-Min;Kim, Seong-Gon
    • The Journal of the Korean dental association
    • /
    • v.44 no.11 s.450
    • /
    • pp.739-747
    • /
    • 2006
  • Objectives. The standardization of connection between fixture and abutment has not been defined. The success of dental implants was not always depends on connection. However, the connection mechanism is one of the most important things for dental implant treatment success. Most implant systems are very comparable in their design and engineering. They share many common characteristics and have similar strengths and weaknesses. Their significant weaknesses are connection, microgap and the resulting micromovement allowing bacterial contamination and bone loss. In the present study, we investigated the clinical performance of Ankylos implant (conical connection implant) Patients and Methods. The clinical performance of conical connection implant was studied under well-controlled clinical conditions. A total of 133 conical connection implants were placed in 50 patients from April 2005 to March 2006. The mean follow-up loading period of implants which was considered successful was 220$\pm$29 days. We recorded the age, sex, installation site, reason of edentulous region, bone density of installation site, diameter and length of dental implants and periods from installation to uncovering surgery using patients medical chart. Results Four Ankylos implants were lost during pre-loading period. 129 implants provided excellent clinical performance during 220$\pm$29 days on an average. The short-term success rate of this conical connection implant system was 96.99%.

  • PDF

Comparative finite element analysis of mandibular posterior single zirconia and titanium implants: a 3-dimensional finite element analysis

  • Choi, Sung-Min;Choi, Hyunsuk;Lee, Du-Hyeong;Hong, Min-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.396-407
    • /
    • 2021
  • PURPOSE. Zirconia has exceptional biocompatibility and good mechanical properties in clinical situations. However, finite element analysis (FEA) studies on the biomechanical stability of two-piece zirconia implant systems are limited. Therefore, the aim of this study was to compare the biomechanical properties of the two-piece zirconia and titanium implants using FEA. MATERIALS AND METHODS. Two groups of finite element (FE) models, the zirconia (Zircon) and titanium (Titan) models, were generated for the exam. Oblique (175 N) and vertical (175 N) loads were applied to the FE model generated for FEA simulation, and the stress levels and distributions were investigated. RESULTS. In oblique loading, von Mises stress values were the highest in the abutment of the Zircon model. The von Mises stress values of the Titan model for the abutment screw and implant fixture were slightly higher than those of the Zircon model. Minimum principal stress in the cortical bone was higher in the Titan model than Zircon model under oblique and vertical loading. Under both vertical and oblique loads, stress concentrations in the implant components and bone occurred in the same area. Because the material itself has high stiffness and elastic modulus, the Zircon model exhibited a higher von Mises stress value in the abutments than the Titan model, but at a level lower than the fracture strength of the material. CONCLUSION. Owing to the good esthetics and stress controllability of the Zircon model, it can be considered for clinical use.

Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis (임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구)

  • Eom, Tae-Gwan;Suh, Seung-Woo;Jeon, Gyeo-Rok;Shin, Jung-Wook;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment.

Three-dimensional Stress Analysis of Implant Systems with Micro Threads in the Maxillary Bone (다양한 마이크로쓰레드(Micro thread)의 개수를 가지는 임플란트의 상부구조물 형상과 하중조건에 따른 3차원 유한요소해석을 이용한 하악골의 응력분포에 관한 연구)

  • Shin Ha-Shik;Han Chong-Hyun;Lee Soo-Hong;Chun Heoung-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.179-186
    • /
    • 2005
  • A comparative study of stress distributions in the maxillary bone with three different types of abutment was conducted. Finite element analysis was adopted to determine stress generated in the bone with the different implant systems with micro threads (Onebody type implant, Internal type implant, and External type implant). It was found that the types of abutments and the number of micro threads have significant influence on the stress distribution in the maxillary bone. They were due to the difference in the load transfer mechanism and the size of contact area between abutment and fixture. Also the maximum effective stress in the maxillary bone was increased with increasing inclination angle of load. It was concluded that the maximum effective stress in the bone was the lowest by the internal implant among the maximum effective stresses by other two types of implants and by appropriate number of micro threads, and that the specific number of micro thread was existed to decrease the maximum effective stress in the maxillary bone due to different implant systems and loading conditions.