• Title/Summary/Keyword: fixture

Search Result 723, Processing Time 0.026 seconds

A Study on a Novel LED Lighting Fixture for Crosswalk Having Two Different Light Distributions (두 가지 배광을 갖는 LED 횡단보도 조명장치에 관한 연구)

  • Kim, Hyeong Jin;Lee, Dong Kyu;Kwak, Joon Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.9
    • /
    • pp.606-611
    • /
    • 2014
  • Recently, LED lighting fixtures for crosswalk become popular in order to recognize the pedestrians at crosswalk, which can enhance the safety of the pedestrian at crosswalk. However, there are several problems related to the LED lighting fixtures for crosswalk, such as a lot of energy consumption due to a constant illumination during night and glaring of pedestrians at the opposite side of crosswalk. In this study, in order to overcome these problems, we have investigated a novel LED lighting fixture for crosswalk, which has two modules with different angles ($60^{\circ}$, $120^{\circ}$). Illuminance of min and max at four-line city street crosswalk shown 50 Lux, 125 Lux, respectively. Illuminance of min and max at eight-line city street crosswalk shown 150 Lux, 200 Lux, respectively. Simulation investigation was optimized design using optical program. Prototype was verified measurement by goniometer system.

Cost Estimation and Economical Efficiency Analysis of Impulse Magnetizer using Semiconductor Switching Device (반도체 스위칭 소자를 이용한 임펄스 착자기의 비용 산정 및 경제성 분석)

  • Kim, Pill-Soo;Kim, Yong;Baek, Soo-Hyun;Kwon, Soon-Do;Yoon, Suk-Ho
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.4
    • /
    • pp.66-73
    • /
    • 1997
  • A capacitor discharge impulse magnetizer using semiconductor switching device is used to produce a high current impulse of short duration in a magnetizing fixture for magnets of the various shapes. The price of today's magnetizer is relatively expensive. This paper described a method for cost estimation of capacitor discharge impulse magnetizer using semiconductor switching device and the economical efficiency analysis. We used a cost structure consisted of five major subsystems. Especially, we estimated the potential for a cost reductions in impulse magnetizer as a function of time using the learning curve, and the potentials of cost by depreciation. The reliable results were obtained by using iron-core fixture coupled to a middle-voltage magnetizer.

  • PDF

The Combination Style Emergency Lighting Fixture which Considers a Dark Adaptation (암순응을 고려한 겸용형 비상조명등)

  • Yoon, Cheol-Gu;Choi, Hong-Kyoo;Lee, Guen-Moo;Kim, Young-Kyu;Kim, Jong-Soo;Chang, Min-Kee;Hwang, Sang-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.145-148
    • /
    • 2009
  • It is sharply decreasing from several hundred[lx] to 1.0[lx] when it turn on the emergency lamps. The sharply decreasing illuminance makes peoples to have dark adaptation for long time. And they were with fear and confused. It also causes secondary accidents by people who take a mistake. This paper studied the combination style emergency lighting fixture to improve a problem of dark adaptations. But it was made an assumption that same conditions of battery capacity and a number of emergency lamps.

  • PDF

Interior heating effect in an office building according to heat properties of light fixture (업무용 건축물의 실내 조명기구 특성에 따른 발열 효과에 관한 연구)

  • Lee, Yoon-Jin;Ahn, Byung-Lip;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong;Kim, Tae-Yeon
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Generally, 30% of the total energy consumption in office building is used for artificial indoor lightings, and almost 75-85% of electric power in fluorescent and Light-Emitting Diode (LED) lightings can be dissipated as a form of heat into indoor environment. The heat generated by indoor lightings can cause the increase of cooling load in office buildings. Thus, it its important to consider indoor lightings as a heat and light source, simultaneously. Method: In this study, we installed two kinds of indoor lightings including fluorescent and LED lightings and measured surface temperature of both indoor lightings. In addition, we obtained ambient temperature of indoor space and finally calculated total heat dissipated from plenum area and surface of lightings. Result: Total indoor heat gain was 87.17Wh and 201.36Wh in cases of six 40W-LED lightings and 64W-fluorescent lightings, respectively.

THE PREVALENCE OF SENSORY DISTURBANCE AFTER IMPLANT SURGERY - RETROSPECTIVE SURVEY OF IMPLANT PRACTITIONERS (임플란트 식립후 하악 신경손상에 대한 후향적 연구)

  • Kwon, Tae-Geon;Kim, Shin-Yu;Kim, Jong-Bae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.339-344
    • /
    • 2004
  • The purpose of this study was to evaluate neurosensory disturbance associated with implant surgery performed by implant practitioner (n=47) composed of trained oral surgeon, periodontist, prosthodontist. The incidence, type and duration of sensory disorder were investigated. Anatomical factor of the patient and experience of operator were also evaluated. The result revealed high incidence of inferior alveolar nerve damage (45%) regardless of experience of implant practitioner. The sensory disturbance sustained within 6 months for 61% of cases, which revealed almost normal recovery of nerve function. Initial neurologic sign after nerve damage was not coincide with their consequence of recovery. Half of the practitioners tried surgical intervention to the implants such as removing the fixture, partial unscrewing or re-implant shorter fixture, of which trial regarded as effective measure for 53% of cases. The result indicates that the objective method of sensory nerve evaluation should be introduced to the implant practitioners and the importance of informed consent for possibility of nerve damage in mandibular implant fixation.

All goods Inspection Convergence System for the Development of LCD Molybdenum Pin (LCD 몰리브덴 핀 개발을 위한 전수검사 융합시스템)

  • Lee, Jeongl-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.183-187
    • /
    • 2020
  • The molybdenum cup and molybdenum pin, which are the main materials of the molybdenum electrode used for the LCD BLU CCFL electrode, have not been developed in Japan and all of them are imported and used from Japan, is giving a competitive burden. In this research, to develop the manufacturing technology of molybdenum pin used for CCFL electrode of LCD BLU, development of linear processing technology, development of molybdenum wire surface treatment technology, development of wire cutting technology, production of molybdenum pin, design and fabrication of JIG and Fixture for inspection, molybdenum pin prototyping and analysis, and development of 100% molybdenum pin inspection technology. In this paper, especially, In this paper, especially, research on the convergency design for total inspection machine is treated. is treated.

Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study

  • Leesungbok, Richard;Seo, Jin-Ho;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.163-166
    • /
    • 2018
  • PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.

IEEE 802.15.4 MAC-based Location-ID Exchange Protocol for Realizing Micro-Cell Connectionless Location- Awareness Services

  • Kim, Baek-Gyu;Kang, Soon-Ju
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.4
    • /
    • pp.412-427
    • /
    • 2008
  • We propose ID-exchange protocol for Connectionless Location-Awareness Service (CLAS) to locate mobile nodes in indoor sensor network. When adapting location-awareness service to sensor network, the target system must be designed in accordance with various metrics which reflect the system requirement. We especially consider sustainability of the existing service which has been provided for its original purpose, such as environmental monitoring. The detailed meaning of sustainability here is that, even if location-awareness service is newly added to the existing service, the system must be assured to retain a stable network condition, and to deal with newly caused traffic properly. The CLAS ID-exchange protocol is especially designed for fixture and mobile nodes communication to achieve these properties. The protocol operates on 802.15.4 MAC layer to make mobile node work independently of the procedure to build routing table of fixture node, so a stable routing condition can be achieved even if there are many mobile nodes. Moreover, the dedicated frequency channel is assigned only for this protocol, so that traffic caused by location-awareness service can be distributed to another channel. A real system adapting the protocol was implemented to monitor fire and authorities' positions. We verified the overhead and elapsed time for location-awareness. The result shows the proposed protocol has a high performance in detecting speed, traffic distribution, and stability of overall network.

An Educational Program of Luminaire Design based on Component Attributes (성분적 속성에 기초한 조명기구디자인 교육프로그램)

  • 박우성
    • Archives of design research
    • /
    • v.14 no.2
    • /
    • pp.57-66
    • /
    • 2001
  • This research was carried with emphasis on the technical contents of lighting design which had various knowledge system in the educational viewpoint. First of all, phisiolosical and physical factors were considered with the process of vision between human and light. Next, components of attributes in the lighting fixture were prescribed to analyze concept of the fixture. Finally, I proposed educational program in the instruction to meet the purpose of this research. As a result, in overall research concerning the basic direction and structure, instruction should have balance to reconcile theory and practice about lighting. Second, in terms of expansion of cognition about lighting, experimental education that is considered with interface is needed to make practical verification through relationship with man-made environment and scientific data.

  • PDF

A VITRO STUDY OF RETAINED SCREW STABILITY BY VARIOUS CONNECTION DESIGNS BETWEEN FIXTURE AND ABUTMENT IN IMPLANT DENTISTRY (임플란트 고정체와 지대주 연결 형태의 차이에 따른 유지 나사 안정성에 대한 연구)

  • Yang Jae-Sik;Vang Mong-Sook;Jo Gyu-Jong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.83-93
    • /
    • 2004
  • Statement of problem : Since the concept of osseointegrated dental implant by $Br{\aa}nemark$ et al was first applied to mandibular full edentulous patients. Recently it is considerated the first treatment option on missing teeth. A common problem associated with dental implant restorations is loosening of screws that retain the prosthesis to the abutment and the abutment to the implant fixture. Purpose : This study is to examine the influence on screw loosening of implant-abutment designs. Material and methods : External hex, cone screw, beveled hex, cam cylinder, cylinder hex by means of evaluating the loosening torques, with respect to a range of tightening torques after repeated loading. Result : 1. Cone screw, beveled hex groups are the highest initial tightening rate and cylinder hex, external hex groups are the lowest initial tightening rate (p < 0.05). 2. Cone screw groups are the highest after repeated loading tightening rate and cylinder hex groups are lowest after repeated loading tightening rate(p < 0.05). 3. Cone screw groups have the highest initial stability and anal stability. 4. All groups are decreased tightening rate after repeated loading.