• Title/Summary/Keyword: fixture

Search Result 723, Processing Time 0.025 seconds

Development of 36[W] LED Fixtures for the Broadcasting Spot Lighting (방송 스폿 조명등기구 36[W]급 LED 등기구 개발)

  • Lee, Jang-Weon;Im, Jee-Weon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.127-135
    • /
    • 2010
  • A study on that LED in 36[W] class replaces broadcast illuminator to save energy and improve the quality of film because tungsten halogen illuminators are too hot and spending lots of electrical capacity at the time of camera shooting. And the following result was obtained .36[w] LED lighting fixture's illuminance is lower than 1[kw] halogen Light but object's illuminance became higher, and at the image be showed very bright and softly.

Design Technology Development of the 28 GHz Up and Down Converters (28 GHz 상향 및 하향변환기 설계기술 개발)

  • Na, Chae-Ho;Woo, Dong-Sik;Kim, Kang-Wook
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.366-370
    • /
    • 2003
  • This paper introduces a new design and fabrication technology of 28 GHz low-cost up and down converter modules for digital microwave radios, The design of the converter module is based on unit circuit blocks, which are to be characterized using a special test fixture. Based on the cascade analysis of the module the 28 GHz up and down converter modules have been designed and implemented. The measured module performance agrees with the cascade analysis. New components such as a tapped edge-coupled filter and a new Ka-band waveguide-to-microstrip transition, which are less sensitive to fabrication tolerances, have been used in the module implementation.

  • PDF

Study on Structure Design of Stationary Fixture Type Automatic Rotary Drilling Machine for Maritime Base Rock (해양암반 고정거치석 자동회전 굴진장비 구조설계에 관한 연구)

  • Jeong, Kyeng-Sik;Lee, Chul-Hee;Lee, Kwang-Hee;Lee, Sun-Kon;Kim, Myeong-Kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.51-54
    • /
    • 2012
  • This paper aims to design and analyze the stationary fixture type automatic rotary drilling machine and estimate the safety of the machine through simulations. Working conditions of typical rock excavating machines are mostly affected by geographical conditions on the sea, such as by the ebb and flow of the tide or high waves. Due to the size of machines, it is difficult to move and install machines. So it is necessary to develop a machine that not only can be moved and installed more easily also be operated more quickly and automatically. To validate the safety of the designed structure of the machine, static analysis has been carried out. The results of stress and deformation analysises show that the designed machine is stable and safe in hard working condition.

Precise Measurement of Center of Gravity Using 3-Point Weighing Method (3점 측정방식을 사용한 무게중심의 정밀 측정)

  • Yoo I.J.;Lee S.P.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.283-284
    • /
    • 2006
  • In this paper 3-point weighing method is adopted to measure the unbalance moment of small-sized precision spinning elements using electronic scales with 0.1 mgf resolution. Firstly methods to eliminate the fixture error and to reduce the effects of frictional force that is known as side effect, are proposed. A measuring system is developed and various experiments are performed to verify the proposed approach. The measured and calculated values are analysed in statistical methods, and this provides the errors of the measuring system. The results show that the proposed theory and test procedures gives reliable unbalance moments and gravitational centers.

  • PDF

A STUDY ON FITNESS OF SEVERAL DOMESTIC IMPLANT FIXTURE AND ABUTMENT SCREWS (국내제작 임프란트 고정체와 지대주 유지나사의 적합도에 대한 주사전자현미경적 비교연구)

  • Park Young-Sun;Vang Mong-Sook;Lee Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.94-109
    • /
    • 2004
  • Statement of problem : Several domestic dental implants have been developed since dental treatment being implants are increasing and popularized. However, they have not been used in domestic market like imported goods. Material and methods : This study was carried out to compare domestic and imported implants in aspect of fitness, dental implant fixture and abutment screw using scanning electron microscope. All experiments were performed under dry condition. Results : 1. Only in aspect of relation of dental implant fkxture and abutment screw, except only one group with point contact, good fitness was existed. 2. Home products must presevere in their efforts, so as excellent to fit.

Surface Transfer Impedance Measurement of RF Cable according to IEC Standard 96-1 (IEC Standard 96-1에 따른 RF 케이블의 표면전달 임피던스 측정)

  • 강진섭;김정환;강웅택;박정일
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.886-892
    • /
    • 2000
  • In this paper, surface transfer impedance measurement of RF cables according to IEC(International Electrotechnical Commission) Standard 96-1 is described and surface transfer impedance of a commercial RF cable is obtained from the measured voltage and scattering parameter with a triaxial fixture fabricated in the operating frequency range from 1 MHz to 30 MHz.

  • PDF

A Case Study on the Compatibility Analysis of Measurement Systems in Automobile Body Assembly

  • Lee, Myung-Duk;Lim, Ik-Sung;Sung, Chun-Ja
    • International Journal of Reliability and Applications
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2008
  • The dimensional measurement equipment, such as Coordinate Measurement Machine (CMM), Optical Coordinate Measurement Machine (OCMM), and Checking Fixture (CF), take multiple dimensional measurements for each part in an automobile industry. Measurements are also recorded under different measurement systems to see if the responses differ significantly over these systems. Each measurement system (CMM, OCMM, and CF) will be considered as different treatments. This set-up provides massive amounts of process data which are multivariate in nature. Therefore, the multivariate statistical analysis is required to analyze data that are dependent on each other. This research provides step by step methodology for the evaluation procedure of the compatibility of measurement systems and clarify a systematic analyzation among the different measurement system's compatibility followed by number of case studies for each methodologies provided.

  • PDF

Development of Multipurpose Welding Jig for Sub-Frame (서브 프레임 제작용 다목적 용접지그 개발)

  • Shin, H.G.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.131-136
    • /
    • 2011
  • In commercial vehicle, sub-frame which equipped in main frame supporting dump deck and oil tanker. This is the main structure for all equipment which including joint function. Sub-frame is made by welding process, this susceptible to deform and crack by its longitudinal size. Also various kind of sub-frame make it difficult to standardization in manufacturing process and exclusive jig is not adapted yet. Frame size is over 6~8m and weight is more than 300kg this make re-work more difficult. If manufacturing company made precise sub-frame, this is not only convenient for customers but also save the company money by reducing the working time. In this study manufacture the sub-frame be suitable for its main function and develop exclusive welding jig for obtain checking fixture function as well.

Hybrid infrared-visible multiview correlation to study damage in a woven composite complex-shaped specimen

  • Andrija Zaplatic;Zvonimir Tomicevic;Xuyang Chang;Ivica Skozrit;Stephane Roux;Francois Hild
    • Coupled systems mechanics
    • /
    • v.12 no.5
    • /
    • pp.445-459
    • /
    • 2023
  • In this study, a cyclic tensile test on a notched butterfly specimen made of woven glass fiber composite was performed on a modified Arcan fixture. During the mechanical test, the sample was monitored with a hybrid stereoscopic system comprised of two visible lights and one infrared camera. The visible light cameras were employed for kinematic measurements using a finite-element-based multiview correlation technique. A semi-hybrid correlation approach was followed, providing Lagrangian temperature fields of the Region of Interest. Due to the complex composite architecture and specimen shape, localized shearing was observed during the tensile loading. Furthermore, asymmetrical damage developed around the notches as revealed by localized strains and thermal hot spots.

Prosthetic restorations with cementless screw-retained implant systems: a case report (시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례)

  • Young-hae Jung;Im-Sun Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.