• 제목/요약/키워드: fixed socket

검색결과 19건 처리시간 0.022초

제거식 쏘일네일의 고정자소켓 강도에 관한 실험적 해석 (Experimental Analysis of the fixed socket strength of a removable soil nail)

  • 김낙경;김성규;윤승권;조규완;김웅규;이충호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1250-1253
    • /
    • 2008
  • As a reinforcement technique, the application of removable soil nailing has been extended to solve the public grievance of typical soil nailing such as the geotechnical environmental problem and invasion of adjacent land. In the case of removable soil nailing, pullout capacity of the nail depends on the adhesive strength of a fixed socket. Because the existing fixed socket is made from a plastic product, the strength of a socket is less than a steel bar and then the yield failure by abrasion and deformation is occurred on the steel bar-socket contact surface. In this study, therefore, experimental analysis from laboratory test of a removable soil nail equipped with steel socket, improving the adhesive strength of steel bar-socket connection is performed to estimate the increase effect of pullout capacity of a soil nail.

  • PDF

현장시험시공을 통한 쐐기형 제거식 쏘일네일링 공법의 거동 평가 (An Estimation of Behavior for Wedge type Removable Soil Nailing System by Field Trial Construction)

  • 한연진;박시삼;권혁준;김홍택;박주석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1360-1364
    • /
    • 2009
  • Necessity of removable soil nailing has been arisen in the soil nailing system because of problem such as civil petition for geotechnical environment and invasion of the ground boundary line and payments for use besides geotechnical engineering. Removable soil nailing system is improved soil nailing system that fixed socket arranged in boring hole for increasement of skin friction. In this study, field pull-out tests are carried out more 4 times considering installed distance of fixed socket and analyze skin friction behavior characteristics in fixed socket through analysis of measurements of strain gauge attached to fixed socket. Also, to evaluate application for wedge type removable soil nailing system analyzing displacement aspects through field pull-out tests by trial construction.

  • PDF

현장인발시험을 통한 제거식 쏘일네일의 거동특성 평가 (Evaluation of Behavior Characteristics of Removable Soil Nails from the Field Pull-Out Tests)

  • 김홍택;강인규;이대형;정성필;박시삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.137-144
    • /
    • 1999
  • Recently a removable soil nail is demanded due to problems beyond of economical and engineering purpose. In this study removable soil nails are developed and field pull-out tests are carried out 16 times in order to analysis pull-out characteristics of the removable soil nail. For the spacing and the installed position of fixed socket, the length of the soil nail, and W/C ratio of cement grout in the removable soil nail, pull-out characteristics of pull-out tests are analyzed. From the pull-out characteristics of removable soil nails, it is found that the spacing of fixed socket and W/C ratio of cement grout are important design parameters.

  • PDF

실내역학 실험을 통한 쐐기형 제거식 쏘일네일링 공법의 적용성 평가 (An Estimation of Wedge Type Removable Soil Nailing System Using by Laboratory Tests)

  • 박시삼;한연진;허성준;윤명준;김홍택;박주석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1330-1333
    • /
    • 2009
  • The soil nailing method had used in variable construction field because of construction convenience and reinforcement effect. Especially, the removal soil nailing method is useful support system in vertical excavation. In this study, to develop the wedge type removable soil nailing method for improvement of the removal soil nailing method. Because of the reinforcement materials is most important in soil nailing method, to evaluate the mechanical characteristics during laboratory strength test in this study. To conduct bond strength test of deformed bar combined with a wedged screw inside plastic fixed socket for evaluate the strength characteristics of wedge type removable soil nailing method and evaluate the strength characteristics of fixed socket based on laboratory tests.

  • PDF

유입부 비대칭 노즐의 성능연구 (Performance Study of Supersonic Nozzle with Asymmetric Entrance Shape)

  • 이지형;김중근;이도형
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.40-45
    • /
    • 2005
  • 현재까지 적용되고 있는 추력제어 장치로는 크게 노즐의 확대부에 장착되어 화염의 방향을 조종하는 제트베인(jet vane), 제트탭(jet tab)방식과 노즐자체를 회전하는 방식인 볼/소켓형(ball & socket) 노즐, 플렉시블 씰형 (flexible seal)노즐로 구분된다. 본 연구는 노즐자체를 회전하여 추력방향을 제어하는 볼/소켓형(ball & socket) 노즐이 회전할 경우 발생되는 유입부의 비대칭성이 노즐 성능에 미치는 영향을 예측하기 위하여 수행한 3차원 수치해석결과와 공압시험 결과를 수록하였다. 유동해석 결과 유입부의 비대칭성이 유동에 미치는 영향은 노즐 목까지 점차적으로 줄어들고 하류 유동에 미치는 영향이 미비하였으며 해석된 주 추력의 크기는 시험에서 측정된 추력과 비슷한 경향을 나타내었으나 측 추력의 경우 시험 값보다 낮게 나타났다.

  • PDF

입체요소를 이용한 현수교 주단강품의 유한요소해석 : 스트랜드슈와 행어소켓 (FE Analysis of Forged Parts of Suspension Bridge : cases of Strand Shoe and Hanger Socket)

  • 최창근;이태열;노혁천;김재철
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.149-156
    • /
    • 1998
  • In suspension bridges, the axial farces in the wires are transferred by side pressure on the semicircular face, and further from the strand shoe through rods to a base plate fixed to the massive concrete part of the anchor block. For prefabricated strands the most common way of anchoring is by socketing the ends of the strands. In this study, strand shoe and hanger socket are analyzed far various load conditions using Finite Element Method. The finite element models are built using MSC/PATRAN and analysis is carried out using MSC/NASTRAN. Results are again completely processed using MSC/PATRAN. From the results of the analysis, trends of deformation and stress distribution are reviewed and important factors to consider in the design of strand shoe and hanger socket are discussed.

  • PDF

콘센트 고정기구 개발 (Development of a Fixed System for Socket)

  • 조병환
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2012년도 춘계학술논문집 2부
    • /
    • pp.607-608
    • /
    • 2012
  • 본 논문에서는 콘센트의 품질이나 기능이 비약적으로 발전하였으나, 기존 노출형 콘센트에 플러그를 연결하는 경우에 쉽게 빠지는 경우가 발생하거나, 콘센트와 플러그가 외부에 바로 노출되어 있어 먼지나 수분에 취약한 문제가 있어 그 해결책을 해결하고자 하였다. 콘센트와 플러그 사이에 콘센트 고정 장치를 결합하는 방법을 제시하고, 매입형 콘센트의 경우에도 고정 장치를 쉽게 결합하여 빠지는 현상을 방지하고, 먼지나 수분에 의한 감전사고 예방 효과를 누릴 수 있는 제품을 개발하고자 하였다.

  • PDF

Improving oral rehabilitation through the preservation of the tissues through alveolar preservation

  • Afrashtehfar, Kelvin Ian;Kurtzman, Gregori Michael;Mahesh, Lanka
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.174-178
    • /
    • 2012
  • When performing a tooth extraction, imminent collapse of the tissue by resorption and remodeling of the socket is a natural occurrence. The procedure for the preservation of the alveolar ridge has been widely described in the dental literatures and aims to maintain hard and soft tissues in the extraction site for optimal rehabilitation either with conventional fixed or removable prosthetics or implant-supported prosthesis.

제거식 쏘일네일 벽체의 적용성에 관한 연구 (A Study on Application of Removable Soil Nail Walls)

  • 김홍택;강인규;정성필;박사원;박시삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.481-488
    • /
    • 1999
  • Recently a removable soil nail is demanded due to problems beyond of economical and engineering purpose. In this study controlled displacement and controlled force field pull-out tests are carried out 7 times in order to evaluate short-term and long-term pull-out characteristics of the removable soil nail. For evaluating application of removable soil nailing system, bending tests of removable soil nails and tensile tests of fixed sockets are carried out. In the removable soil nailing system, the predicted horizontal displacements from FLAC-2D are also compared with the field measurements occurred in stepwise excavation. And approach for the stability analysis of removable soil nailing system after removed is proposed.

  • PDF

The effects of hard and soft tissue grafting and individualization of healing abutments at immediate implants: an experimental study in dogs

  • Thoma, Daniel S.;Jung, Ui-Won;Gil, Alfonso;Kim, Myong Ji;Paeng, Kyeong-Won;Jung, Ronald E.;Fickl, Stefan
    • Journal of Periodontal and Implant Science
    • /
    • 제49권3호
    • /
    • pp.171-184
    • /
    • 2019
  • Purpose: To evaluate the effects of intra-alveolar socket grafting, subepithelial connective tissue grafts, and individualized abutments on peri-implant hard and soft tissue outcomes following immediate implant placement. Methods: This randomized experimental study employed 5 mongrel dogs, with 4 sites per dog (total of 20 sites). The mesial roots of P3 and P4 were extracted in each hemimandible and immediate dental implants were placed. Each site was randomly assigned to 1 of 4 different treatment groups: standardized healing abutment (control group), alloplastic bone substitute material (BSS) + standardized healing abutment (SA group), BSS + individualized healing abutment (IA group), and BSS + individualized healing abutment + a subepithelial connective tissue graft (IAG group). Clinical, histological, and profilometric analyses were performed. The intergroup differences were calculated using the Bonferroni test, setting statistical significance at P<0.05. Results: Clinically, the control and SA groups demonstrated a coronal shift in the buccal height of the mucosa ($0.88{\pm}0.48mm$ and $0.37{\pm}1.1mm$, respectively). The IA and IAG groups exhibited an apical shift of the mucosa ($-0.7{\pm}1.15mm$ and $-1.1{\pm}0.96mm$, respectively). Histologically, the SA and control groups demonstrated marginal mucosa heights of $4.1{\pm}0.28mm$ and $4.0{\pm}0.53mm$ relative to the implant shoulder, respectively. The IA and IAG groups, in contrast, only showed a height of 2.6mm. In addition, the height of the mucosa in relation to the most coronal buccal bone crest or bone substitute particles was not significantly different among the groups. Volumetrically, the IA group ($-0.73{\pm}0.46mm$) lost less volume on the buccal side than the control ($-0.93{\pm}0.44mm$), SA ($-0.97{\pm}0.73mm$), and IAG ($-0.88{\pm}0.45mm$) groups. Conclusions: The control group demonstrated the most favorable change of height of the margo mucosae and the largest dimensions of the peri-implant soft tissues. However, the addition of a bone substitute material and an individualized healing abutment resulted in slightly better preservation of the peri-implant soft tissue contour.