High Temperature Properties of Alumino Silicate Fire Protection Materials Using Fly ash (플라이애쉬 활용 Alumino silicate계 내화마감재의 고온특성)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu;Park, Nam-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.689-692
    • /
    • 2008
  • HSC(High Strength Concrete) have superior properties well as improvement in durability compared with normal strength concrete. In spite of durability of HSC, explosive spalling of concrete is serious problem in structure safety. Therefore, Solving methods are required to control the explosive spalling. The properties of concrete are affected by changes of temperatures. Compressive strength and elasticity modulus were degraded depending on a rise of temperatures. Also, change in microstructure and dehydration of concrete subjected to high temperatures. This paper is concerned with change in microstructure and dehydration of the alumino silicate fire protection materials at high temperatures. The testing methods of fire protection materials in high temperature properties are make use of SEM, TG-DSC and XRD. From the experimental test results, influence of high temperatures on microstructure of alumino-silicate fire protection material was identified, including chemical dehydration of C-S-H and CH. The chemical dehydration of CH under various temperatures from to 450 to 600$^{\circ}$C has been measured using the TG-DSC. However, developed alumino silicate fire protection materials showed good stability in high Temperatures. Thus, the results indicate that it is possible to fireproof panels, fire protection of materials.

  • PDF

A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture (실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구)

  • Cho, Sung-O;Kim, Yong-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

A Study on the Spalling Properties of Polymer Modified Cement Mortar Using Polypropylene Fiber (폴리프로필렌 섬유를 혼입한 폴리머 시멘트 모르타르의 폭렬특성에 관한 연구)

  • Kim, Min-Sung;Sim, Sang-Rak;Ryu, Dong-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.305-311
    • /
    • 2020
  • Polymer modified cement mortar (PCM) can improve the performance of adhesion strength, flexural strength, chemical resistance, etc., compared with cement mortar, and is widely used when repairing RC structures. However, PCM causes a burst in an environment with high temperature and fire rate, which causes problems in the stability of the structure. In this study, for the purpose of developing explosive reduction PCM, the polymer mixing ratio is 2%, 4%, 6%, the fiber length is 6mm, 12mm, 6+12mm, and the PP fiber mixing rate is 0.05 Vol% and 0.1 Vol%. Furnace heating experiment (600℃, 800℃) was carried out. As a result of comparative analysis of the explosive properties, it was confirmed that the explosive reduction effect due to the fiber incorporation was insufficient when the polymer mixing amount was 6% or more.

Evaluation of Adhesion Performance of High-Fireproofing Alumino-silicate Inorganic Mortar (알루미노 실리케이트계 고내화성 모르타르의 부착성능 평가)

  • Cho, Hyeon-Seo;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.569-576
    • /
    • 2018
  • In modern society, a huge number of the buildings have been constructed with RC structure. RC structures have many structural instabilities due to earthquake, typhoon, construction fault, design phase errors. Therefore, many reinforcement methods are being implemented to solve this problem. In the reinforcement method, the organic epoxy adhesive used in the FRP reinforcing method is abruptly damaged when exposed to high temperature, which is directly connected to the fall of the reinforcing material. Therefore, the present study was conducted to develop inorganic refractory mortar with a certain level of adhesion ability to reduce the heat transferred to FRP reinforcement when exposed to high temperatures. As a result of the test, it showed high adhesion strength at room temperature condition with the inclusion of EVA resin, and showed no performance deterioration up to about $300^{\circ}C$ even under heating conditions. Also, it was confirmed that the backside temperature was lower as the thickness increased, and converged to a constant temperature of about $780^{\circ}C$ after 2 hours of heating.

A Study on Fire Prevention Measures through Candle Fire Case and Reproduction Experiment (촛불화재사례 및 재현실험을 통한 화재예방대책 연구)

  • Lee, Jeong-Il;Kim, Young-Soo
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.1
    • /
    • pp.12-19
    • /
    • 2019
  • Purpose: The purpose of the study is to reduce the fire of the same type by analyzing the form which is mainly generated based on the result of the fire investigation through the experiment to reproduce, since the candle fire is repeated every year with the same type. Methods: For the analysis of candle flame, 4 kinds of methods such as acrylic recharge test, FOMEX acrylic recharge test, general combustible recharge test, and natural fire extinguishing test of candle were conducted. Results: It was confirmed that continuous burning is difficult to be achieved without contact of combustible materials around. Conclusion: In order to prevent a candle fire, it is important to check the safety of the surrounding area. It is also considered to introduce safety regulations such as finishing with a fireproof material such as a silver foil at the terminal end.