• 제목/요약/키워드: fire-resistant

검색결과 268건 처리시간 0.03초

강구조 내화성능의 이론적 평가방법에 관한 조사연구

  • 성시창
    • 방재기술
    • /
    • 통권20호
    • /
    • pp.42-47
    • /
    • 1996
  • Prior to real fire test, theoretical of the fire resistant performance of the structural ele-ments is often less time consuming and less costly to calculate it, than to determine the perform-ance experimentally. This study is aimed at introduction of estimating methods of the fire resistant performance of the steel structural elements not by the actual fire tests but by the mathematical models.

  • PDF

표준화재에 노출된 방염처리 목재의 내부온도에 관한 연구 (Study on the Internal Temperature of Flame Resistant Treated Wood Exposed to a Standard Fire)

  • 김황진
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.14-18
    • /
    • 2018
  • 건축 재료로 사용되는 목재의 내화성능에 관한 기존 연구들은 목재에 난연 또는 방염 처리하였을 경우 연소특성을 확인하는 것에 집중되어 졌다. 본 논문에서는 화염에 노출된 목재의 열분해와 밀접한 관련이 있는 내부 온도 변화를 확인하기 위하여 건축용 구조재로 널리 사용되는 미송(Douglas-fir)에 방염액 및 방염도료를 처리 후 표준 가열 온도 곡선에 따라 수평가열로에서 가열실험을 실시하였다. 실험결과 방염액을 처리하였을 때 목재내부의 열확산이 현저히 감소하는 것을 확인할 수 있었으며 방염도료를 처리한 시료의 경우 고온에 노출 되었을 때 도막이 박리되어 방염효과를 기대할 수 없었다. 따라서 두꺼운 목재에 방염효과를 높이기 위해서는 목재표면에 도막을 형성시키는 방염도료보다는 목재내부로 침투하는 방염액을 사용하는 것이 방화효과가 클 것으로 판단된다.

양단 고정단인 건축용 내화강재 적용 보부재의 해석적 내화성능 연구 (Analytical Study of the Fire Resistance for Beams Consisting of Fire Resistant Steels with a Both Fixed Boundary Conditions)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.82-86
    • /
    • 2016
  • 건축용 내화강재가 적용된 양단 고정단 보부재의 고온 시 최대 내력과 처짐을 해석적으로 평가하였으며, 이 결과를 일반강재 적용 정정 보부재와의 비교평가를 통하여 안전성을 평가한 결과, 건축용 내화강재 적용 부정정 보부재의 내화성능을 일반 강재 정정 보부재로 평가되는 것은 안전측이었으며, 부재길이가 길어지면 처짐의 증대와 최대 내력의 감소가 유발되는 등 이에 대한 보완책이 요구되는 것으로 나타났다.

내화피복을 적용한 강합성보의 구조화재해석 (Structural Fire Analysis of a Composite Beam Protected by Fire-Resistant Materials)

  • 강준원;강문수;윤혜진
    • 한국전산구조공학회논문집
    • /
    • 제36권2호
    • /
    • pp.137-145
    • /
    • 2023
  • 이 논문은 정적 재하상태에 있는 무피복 강합성보와 내화피복을 적용한 강합성보를 대상으로 화재 시 내부 온도 및 수직처짐에 대한 내화피복의 영향을 평가한 결과를 제시한다. 열응력해석을 위한 화재하중으로는 American Society for Testing and Materials E119의 표준화재곡선을 사용했으며, 강재거더 표면에 부착하는 내화재료의 방화효과를 구현하기 위해 외기에서 강합성보로 전달되는 열의 전달계수를 감소시켰다. 실규모 무피복 강합성보에 대한 구조화재실험에서 내부 온도분포와 수직처짐을 측정하였고 실험 결과와의 비교를 통해 비선형 구조화재해석 결과의 타당성을 검증하였다. 내화피복이 적용된 강합성보의 구조화재해석 결과로부터 강재거더 표면에 내화재를 적용할 경우 동일 화재 조건에서 무피복 강합성보에 비해 내부 온도와 수직처짐이 감소함을 알 수 있었다. 또한 열전달계수의 변화에 따른 열응력 응답으로부터 화재 시 강합성보의 온도 및 구조거동에 대한 내화피복의 영향을 제시하였다.

A simplified analysis of catenary action in steel beams in fire and implications on fire resistant design

  • Wang, Y.C.;Yin, Y.Z.
    • Steel and Composite Structures
    • /
    • 제6권5호
    • /
    • pp.367-386
    • /
    • 2006
  • This paper describes the results of a numerical investigation of the large deflection behaviour of steel beams under fire conditions, taking into consideration the effect of catenary action provided by the surrounding structures. The main focus is on the development, validation and application of a simplified calculation method that may be adopted in design calculations. Because no experimental result is available for validation of the simplified calculation method, the finite element program ABAQUS has been used to simulate the large deflection behaviour of a number of steel beams so as to provide alternative results for validation of the proposed method. Utilising catenary action has the potential of eliminating fire protection to all steel beams without causing structural failure in fire. However, practical application of catenary action will be restricted by concerns over large beam deflection causing integrity failure of the fire resistant compartment and additional cost of strengthening the connections and the surrounding structures to resist the catenary forces in the steel beams. This paper will provide a discussion on practical implications of utilising catenary action in steel beams as a means of eliminating fire protection. A number of examples will then be provided to illustrate the type of steel framed structure that could benefit the most from exploiting catenary action in fire resistant design.

뿜칠피복 각형 강관의 내화성능 평가를 위한 실험적 연구 (An Experimental Study on the Evaluation of the Fire-Resistance Performance of a Spray-Applied Rectangular Steel Structure)

  • 옥치열;김재준
    • 한국공간구조학회논문집
    • /
    • 제17권1호
    • /
    • pp.41-47
    • /
    • 2017
  • Structures of steel frame buildings getting vary depending on the development of construction technology. Fire-resistant steel beams and Columns accredited by accreditation bodies from the performance of various fire-resistant coating is applied to the current pillar method is most H-beams. H-beam has been proposed a non-load test specifications in the relevant regulations, its scope of accreditation to be granted without limitation of size H-beams from the performance of the test specification. However, in the case of the rectangular steel structure is to check its performance and to a separate one of the receive acknowledge and so take advantage of the cross-sectional shape factor in this study to test the performance of the fire-resistant structure proposed for standard test specimen.

내화강재의 고온특성 데이터베이스 구축 연구 (Experimental Study on Making Databases for Fire Resistant Steel at High Temperature)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제27권5호
    • /
    • pp.1-7
    • /
    • 2013
  • 가연물의 증가는 건축물 화재의 발생 위험성과 재해발생 규모를 점차적으로 증대시키는 요인이 되고 있다. 따라서 강구조 건축물의 화재에 대비한 기술개발이 요구되었으며, 이 결과로 내화강재가 개발되었다. 본 연구에서는 FR 490강재의 고온 시 기계적, 열적 특성을 실험적으로 평가하고, 이 결과를 상온 시 구조적 내력이 동일한 용접구조용 강재인 SM 490과 상호 비교함으로써 고온 시의 내력유지 성능이 우수함을 확인하였다.

난연도료를 도장한 바탕재의 화재 위험성평가 (A Fire Risk Assessment of Substrate for Fire Resistant Painted)

  • 박영근;이두형;윤명오;현성호
    • 한국화재소방학회논문지
    • /
    • 제19권1호
    • /
    • pp.51-58
    • /
    • 2005
  • 본 연구는 새로 개발된 난연도료를 바탕재(FRP PVC, AL, 스테인레스 스틸)에 도장한 실험체에 대하여 난연성. 화염전파. 산소지수. 가연성, 연기밀도, 독성지수를 평가하였다 연구결과 실험체(AL, 스테인레스 스틸)의 난연1급실험은 적합하였으며, 실험체(FRP, AL, 스테인레스 스틸)의 화염전파실험에서 착화되지 않았고, 실험체 모두의 산소지수는 약 $50\%$, 가연성실험은 V-0급으로 나타났다. 또한 연기밀도 챔버를 이용한 Flaming mode에서 최대연기밀도는 43-338 및 덕성지수는 0.57-1.12인 것으로 나타났다.

알루미노 실리케이트계 내화보드의 내화성능 및 현장적용성 평가 (An Evaluation of Fire Resistance and Mock-up Test of the Alumino-silicate Fire Resistant Board)

  • 김두호;박동철;김우재;이세현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 2부
    • /
    • pp.43-47
    • /
    • 2010
  • The use of high-strength concrete has increased for its excellent structural stability as buildings become higher and bigger than ever before in Korea and overseas recently. The functional requirement of building materials has also been bolstered so for the high -performance, high-quality construction materials to be used more extensively. However, the internal structure of the high-strength concrete is very dense so spalling can be caused during fire. The spalling in turn can cause critical structural damages followed by the fatal consequences, demolition of the building. Therefore, ensuring fire safety for high-rise buildings is assumed to be urgent. Alumino-silicate fire resistant board producing technology has been developed in situations that new materials with excellent fire resistance and easy installation has been sought. The alumino-silicate fire resistant board turned out to exhibit not only fire resistance and excellent physical and dynamical characteristics but also excellent onsite applicability and easy process and transportation after completing Mock-up test. Its excellence as a high-performance building materials was proven.

  • PDF

내화피복 강재의 내화성능 평가 예측에 관한 연구

  • 성시창
    • 방재기술
    • /
    • 통권17호
    • /
    • pp.5-9
    • /
    • 1994
  • With a rapid development of economy, more high-rise buildings are being constructed in large cities than before. As a result steel members such as beams, columns make a great role of the building construction, and the need of them to be protected to have enough fire resistance is in-creasing . But conducting a real fire test to all the members is almost impossible. So prior to do conduct a real fire test of the protected steel members, evaluating the fire resistant rating of them by means of their specific properties might be economical things. This study is aimed to introduce the fire resistant rating of protected steel members without a real fire test through the related studies and data.

  • PDF