• Title/Summary/Keyword: fire-preventing area

Search Result 25, Processing Time 0.023 seconds

Improvement of fire protection equipment the opening of according to narrow the distance between buildings (건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

Comparison a Forest Fire Spread variation according to weather condition change (기후조건 변화에 따른 산불확산 변화 비교)

  • Lee, Si-Young;Park, Houng-Sek
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.490-494
    • /
    • 2008
  • We simulated a forest fire which was occurred in Yangyang area on 2005 and compared a results between two different weather conditions(real weather condition and mean weather condition since 1968) using FARSITE, which is a forest fire spread simulator for preventing and predicting fire in USDA. And, we researched a problem in the transition for introducing, so we serve the basic method for prevention and attacking fire. In the result, severe weather condition on 2005 effected a forest fire behavior. The rate of spread under real weather condition was about 4 times faster than mean weather condition. Damaged area was about 10 time than mean weather condition. Therefore, Climate change will make a more sever fire season. As we will encounter to need for accurate prediction in near future, it will be necessary to predict a forest fire linked with future wether and fuel condition.

  • PDF

A Study on the Performance and the Improving Methods of the Building Fire Compartment under the Domestic Fire Safety Regulations (국내 방화규정에 따른 건축물 방화구획 성능 및 개선방안에 관한 연구)

  • Chun, Woo-Young;Lee, Kwang-Won;Lee, Ji-Hee;Kim, Wha-Jung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.19-24
    • /
    • 2008
  • Recently, the buildings have gradually become higher, more massive and more complex with high growth of economy and varieties of the patterns of people's living. Therefore we study a performance and Improving Methods of the fire compartment as a measure to minimize the damage of the people and property from the fire. Currently, under the economic crisis situation, we do not consider about prevention of disaster safety enough; safety investment evasion, safety carelessness, and management relaxation etc. Also in the aspect of regulation system, industrial technology and plan engineering, Korean techniques of preventing fire disasters are far behind of other advanced nations. At this point, we are in need of improving about it. When considering like this situation, we need more studies on the practical improvement in order to assure fire prevention for buildings. The fire compartment prevent from magnifying the fire to the wide area by compartment into specific area. From this, it is possible to minimize fire damage and property and secure emergency exit for life safety. This fire compartment has primary function to extinguish fire easily, and the openings and penetrations are important passage which makes the smoke and fire go away from the fire area to the contiguous space. This study suggests improving methods of domestic fire compartment efficiency standard through comparative analysis of overseas advanced provision and domestic provision about base element of the building fire prevention.

  • PDF

A Study on the Fire Protection System in the Stage (공연장의 소방시설 설치기준의 개선방안에 관한 연구)

  • 장상태;이영재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-19
    • /
    • 1999
  • Currently, conventional fire prevention facility installation standard is based on the use and size of the domestic theaters. In the study, theaters with 1,900 seats were examined to suggest a suitable method to adapt a better fire preventing system. The proposed systems are as follow. - 100% of backup pressed-water outlet device, considering waterproof pressure for fire prevention facility at the top floor. - The supplement of the side wall type header and a large caliber outlet header for stage open sprinkler. - Subdividing a installation rule for special detector and implementing the latestdetector. - Installation of fire curtain for dividing stage area and auditorium area, and also the method of installation of fire curtain.

  • PDF

Applicability of CO2 Extinguishing System for Ships (질식사고 방지용 CO2 소화설비의 선박 적용성)

  • Ha, Yeon Chul;Seo, Jung Kwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.4
    • /
    • pp.294-300
    • /
    • 2017
  • The offshore installations and ships are the structures most likely to be exposed to hazards such as hydrocarbon fire and/or explosion. Developing proactive measures to prevent the escalation of such events thus requires detailed knowledge of the related phenomena and their consequences. $CO_2$ extinguishing systems are extensively used for fire accidents of on-and offshore installations because of outstanding performance and low cost. There is, however, the risk of carbon dioxide system which enumerates many of the fatalities by suffocation associated with industrial fire protection requirements. Therefore, the aim of this study is to perform the prediction of fire suppression characteristics of the carbon dioxide system in realistic enclosed compartment area of ships and propose $CO_2$ extinguish fire fighting system for preventing suffocation accidents during fire fighting. According to CFD calculations, it can be observed and assessed that various fire profiles with $CO_2$ and $O_2$ mole fraction in the target enclosed compartment area are applicable within the proposed system. Additionally, the design of fire safety system of ships and offshore installations can utilize ventilation system and/or layout arrangement through the proposed system.

Research on FARSITE for introducing a Forest fire simulator (산불확산 시뮬레이션 도입을 위한 FARSITE 고찰)

  • Lee, Si-Young;Park, Houng-Sek
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.161-164
    • /
    • 2008
  • We studied a basic concept and application about FARSITE, which is a forest fire spread simulator for preventing and predicting fire in United States Department of Agriculture(USDA). And, we researched a problem in the transition for introducing, so we serve the basic method for prevention and attacking fire. For this transition, we compared the behavior of the 2005 Yangyang forest fire with the result of a simulation. The spread direction is similar to real data. But, while mean spread of rate was 0.65km/hr on real data, it was 0.3km/hr on simulation. As Damaged area is 1,387ha on real, it was 5,368ha on simulation. Therefore, it is necessary to establish a fuel concept for more accurate simulation.

  • PDF

Stability Analysis of the Foundation of Hazardous Material Storage Tank for Preventing Leakage Accidents (누출사고 방지를 위한 위험물 탱크의 기초 안정성 분석)

  • Lim, Jong-Jin;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.96-100
    • /
    • 2020
  • The leakage of hazardous materials due to the defect in storage tank foundations is likely to cause tremendous fire disasters in the industry cluster area. Thus, adequate design and construction of the tank foundation is required for preventing tank leakage. In this study, four types of typical tank foundations were classified and modeled for 3D FEM analysis to perform stability evaluation on tank foundations. Furthermore, numerical analysis indicated that stress concentration just below the tank shells is 40 times that at the tank center. The settlement influence zone is about the tank radius and tank diameter in the horizontal and vertical directions, respectively. Thus, the appropriate guidelines for the design and construction of tank foundations were suggested via a comparison assessment of the numerical analysis results on the stress distribution and displacement of the tank foundations.

A Study on the Usage of Hwabangbyeok wall in Traditional Architecture in Joeson Dynasty (조선시대 전통건축에서의 화방벽(火防壁) 사용에 대한 연구)

  • Jo, Sang-Sun
    • Journal of architectural history
    • /
    • v.29 no.3
    • /
    • pp.7-14
    • /
    • 2020
  • It can be meaningful that this study attempted to analyze the use cases and forms based on the literature on the painting walls of the J oseon Dynasty, and attempted basic research to prevent disaster damage using traditional elements. This study summarizes the use of the Hwabangbyeok wall of J oseon Dynasty as follows. First, Hwabangbyeok wall was used from the early J oseon Dynasty and was adopted by palaces and other major state facilities to cope with fire and theft. Second, the Hwabangbyeok Wall was also referred to as the wall below the lower part of the wall, and was constructed with the purpose of preventing disasters from outside. Third, in an analysis of the Daeseongjeon shrine of Hyanggyo, many construction cases were identified mainly in the Gyeonggi area, which is assumed to be based on production and construction conditions along with local climatic factors. Fourth, it can be said that the Hwabangbyeok wall was basically adopted to prevent comprehensive disaster risk reduction in case of external intrusion and fire.

Analysis of Vulnerability of Emergency Transport Service for Flooded Area (침수피해지역의 응급이송서비스 취약성 분석)

  • Lee, Yoon-Ha;Hong, Won-Hwa;Lee, Ji-Soo;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.122-130
    • /
    • 2018
  • Recent urbanization, population densification, and the impact of global climate change are causing disasters to become larger and more complex. Meanwhile, in Korea, there is an emphasis on preventing, restoring, and recovering from disasters. However, disaster medical care, which is absolutely necessary to maintain life in a disaster, is being ignored. Therefore, in this study, we selected Seoul as the study area where flood damage is frequent and underground housing is densely populated. Assuming underground housing in the immersion history area as the emergency patient site, transfer distance and transfer time were analyzed. This study considered both accessibility to emergency medical facilities and disaster sites and accessibility from emergency services to disaster sites. Therefore, it seems to be meaningful as basic data for the improvement of emergency medical services.

Study of evacuation fire doors in multiple facilities (다중이용시설의 피난방화문에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7380-7384
    • /
    • 2014
  • Evacuation fire doors were manufactured by applying phosphorescent paint to the whole fire door whose performance was already recognized, and applying heat sensitive paint around the grip. The facility was improved by the evacuation and safety functions on the fire door, which has been used as only a fire facility, and the fire door is also used as an evacuation facility. The brilliance of the evacuation safety fire door manufactured in this study passed the brilliance test of Korea Fire Institute with a performance more than the brilliance (7mcd after 60 minutes) of the existing inducement sign. During a fire, the visible area is larger than the evacuation door inducement, etc. and light preventive status in the lower part of the fire door was observed during the descent of smoke. Therefore, it is considered to extend the evacuation effective time of evacuators. In heat sensitive paint applied around the grip, a color change is observed on the fire door when approaching a certain temperature ($70^{\circ}C$). Therefore, the first disaster that evacuators can encounter on the grip of a fire door during a fire can be prevented and should be helpful in recognizing the backfiring possibility and preventing safety accidents for firefighters who must enter a fire space.