• 제목/요약/키워드: fire risk analysis

검색결과 493건 처리시간 0.022초

성장화재통계 기반 건축물 용도별 화재위험도에 관한 기초연구 (A Basic Study on the Fire Risk by Building Use based Growth Fire Statistics)

  • 서동구;이종호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.218-219
    • /
    • 2020
  • The risk of a fire in a building is closely related to the usage of the building. In particular, all fires that occur in a building are not risky to safety of human life, and it is associated with the combustion area and the increase of total floor area of the building. Therefore, this study focused on safety of human life in terms of the statistics of fire with considering the aspect of growing fires and analyzed the statistical data of fire for 10 years. As for the analysis on fire, the time of occurrence by usages of buildings, frequency of occurrence and the ratio of casualties etc. were analyzed. It is expected that results of this study could be used for evaluations on a variety of parts in terms of design, construction and maintenance of buildings.

  • PDF

터널 방재설비의 합리적 설치를 위한 분석적 연구 (An analysis study for reasonable installation of tunnel fire safety facility)

  • 박진욱;유용호;박병직
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.243-248
    • /
    • 2015
  • 최근 국내에서는 도로 및 철도 터널의 건설이 꾸준히 증가하고 있으며, 교통체증 해소 및 도시계획 그리고 개량공사 등에 따라 터널이 더 깊은 지하에 위치하거나 장대화되고 있는 추세이다. 이러한 경우 터널 내부사고 중 인명피해에 가장 큰 위험요소인 화재사고가 발생할 경우 대형사고로 이어질 확률이 굉장히 높아진다. 본 연구에서는 정량적 위험도 분석 기법인 QRA(Quantitative Risk Analysis)를 터널에서의 방재설계에 적용하고자 국내 QRA 사례분석을 수행하고, QRA 기법의 적용 유무에 따른 비용 산출을 비교하였다. 그리고 AHP(Analytic Hierachy Process)기법을 사용하여 터널 방재시설의 위험도 저감 효과를 분석하여 터널 화재시 위험도를 낮출 수 있는 중요 인자들에 대한 우선순위를 제시 하였다. 그 결과로부터 QRA가 적용된 사례에서 상당한 비용절감 효과가 나타났으며, 그로 인해 합리적인 방재시설의 설계가 가능할 것으로 판단하였다. 그리고 방재시설별 비용대비 위험도 저감효과를 통한 방재시설 우선순위는 송수관설비, 비상조명, 대피통로, 제연설비의 순으로 분석되었다.

경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석 (Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period)

  • 김민호;이석희;이민철;이상규;이주은
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

(초)고층 건축물의 화재위험성 평가기법 개발에 관한 연구(I) (A Study on the Development of Evaluation Methods for Fire Risk Analysis of High-rise Building)

  • 권영진;신이철
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.223-228
    • /
    • 2008
  • Fire is recognized as a significant hazard in a service life of a structure. Therefore there is a clear need to provide an improved understanding of the performance of material and structures in fire and to provide clear design guidance in order to progress safety design especially high rise building. It is the aim of this study to investigates and analyze the study on the development of evaluation methods for fire risk analysis of high-rise building.

  • PDF

고무제품제조공장의 가류공정에 설치된 유도전동기의 설치환경 및 화재위험성 분석 (Analysis of Installation Environment and Fire Risk of Induction Motors Installed in the Curing Process of a Rubber Product Manufacturing Plant)

  • 이종찬;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권2호
    • /
    • pp.23-29
    • /
    • 2023
  • This study analyzed the fire status of a rubber product manufacturing factory based on 19 years of fire data. Through the analysis of the current state of fire, electrical fires accounted for 58.19%, and among electrical fires, motor fires were the highest at 26.21%. For the motor fire occurrence process, the curing process accounted for the highest rate of 51.9%. Therefore, the installation environment was investigated for the motor in the curing process, and it was confirmed that the motor's maximum ambient temperature exceeded 40℃. In particular, in the case of the motor for curing operation, the motor was installed in a separate motor room, so the average indoor temperature was 48.10℃ and the motor frame's maximum temperature was 72.80℃. In this study, the risk of motor fire was confirmed through a field survey, and a safety management plan was derived by finding a process with high fire risk and conducting an experiment on the motor's installation environment and electrical characteristics in that process.

Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석 (Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP)

  • 김명철;김학중;박경환;윤해권;이승호
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.87-94
    • /
    • 2019
  • 국민권익위원회 2018년 7월 17일 보도 자료에 의하면 방탈출카페, 실내양궁장 등 신종업종이 다중이용업에서 제외되어 지정을 검토하고 화재예방 대책을 수립하도록 소방청에 권고하였다. 본 연구는 Delphi 기법으로 다중이용업 신종업종의 화재위험평가 측정영역 및 측정지표를 계층화하고 적합도(3.00 이상) 분석결과, 적합도 평균값이 4.25로서 적합성을 확보하였다. AHP 분석결과, 화재위험평가 측정영역의 일관성 비율은 4.0%로서 CR ≤ 0.1(10%) 보다 낮게 분석되었고 하위 측정지표의 일관성 비율도 0.1%~3.6%로서 모두 일관성이 있음을 확인하였다. 통합 측정지표의 중요도와 우선순위는 영업장 내부통로의 형태 및 출구의 피난능력(0.316), 점화원관리(0.141), 고유위험(0.106), 화재감지시스템의 적절성 및 적응성(0.097), 가연물관리(0.084), 피난안내 및 피난설비(0.075), 내화구조 및 마감재료(0.060), 구획 및 비상구(0.049), 연소확대위험(0.046), 소화설비의 적절성 및 적응성(0.026)의 순으로 도출 되었다. 본 연구는 향후, 화재위험평가지표 개발 연구의 중요한 자료로 널리 활용 될 것이다.

국내 자동차 관련 화재발생 위험성 분석 및 초기소화의 효과성 연구 (The Analysis of the Risk of Vehicle Fires in Korea and the Effectiveness of Initial Fire Extinguishing)

  • 류주열;이창우
    • 한국재난정보학회 논문집
    • /
    • 제15권1호
    • /
    • pp.20-27
    • /
    • 2019
  • 연구목적: 본 연구에서는 국내 자동차 관련 화재발생 현황 및 위험성을 평가하고 초기 소화기구의 사용에 따른 피해저감 효과에 대해 평가하였다. 연구방법: 국내 자동차 화재의 발생 빈도에 대한 위험성 분석과 화재발생시 자동차에 비치되어 있는 소화기를 사용하여 초기 소화에 적용한 사용에 따른 인적 및 재산피해를 분석하였다. 연구결과: 국내 자동차 화재 발생에 따른 건당피해액은 연평균 증감률이 4.74%이고 매년 증가하는 것으로 나타났다. 자동차 화재현황 중 승용자동차에서 발생한 인명피해를 연도별 화재발생 건당 인명피해로 분석한 결과, 화재발생 100건당 재산피해액은 424.65만원에서 473.06만원으로 과거 5년간(2012년~2016년) 지속적으로 증가하는 추세를 보이고 있다. 결론: 승용자동차 화재시 소화기를 사용한 경우에는 화재발생 1건당 평균 재산피해액은 약 307.5만으로 산정되어 초기 자동차 화재에 차내에 비치된 소화기를 사용한 초기소화의 중요성과 필요성이 요구된다.

국내 원자력발전소 화재안전 대책에 관한 연구 (A Study on the Fire Safety Measures of Korean Nuclear Power Plants)

  • 김학중;손봉세;허만성
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2003년도 춘계학술논문발표회논문집
    • /
    • pp.259-264
    • /
    • 2003
  • The fire protection system of Nuclear Power Plants(NPPs) is an integrated system that is applied multi-field technology. So, it needs synthetic design and analysis, that is, the plan of fire protection, fire compartment, fire detection, fire suppression, and success of safety shut down, etc. In case of a fire in NPPs, secure the safety of reactor and minimize the radioactivity contamination. For this purpose, perform the fire risk analysis and make up the deducted problem through the improvement of design or the change of operation process.

  • PDF

진주시 화재발생 패턴분석과 위험등급 산출 (Fire Occurrence Pattern Analysis and Fire Risk Calculation of Jinju City)

  • 배규한;유환희
    • 대한공간정보학회지
    • /
    • 제22권4호
    • /
    • pp.151-157
    • /
    • 2014
  • 급속한 도시성장에 따라 도시지역에는 다양하고 복잡한 시설물들이 증가되고 있으며, 이에 따른 화재발생 피해에 대한 위험도도 증가되고 있다. 특히 화재사고는 인위적 재해 중 교통사고와 함께 도시지역에서 가장 높은 발생빈도를 나타내고 있다. 이에 따라 소방방재청에서는 효과적인 화재관리를 위하여 국가화재정보시스템을 운영하고 있으며 2007년부터 화재발생정보를 인터넷을 통해 제공하고 있다. 따라서 본 연구에서는 이 시스템에서 제공하는 데이터와 진주시 소방서로부터 자료를 취득하여 진주시 화재데이터베이스를 구축하고, 2007년부터 2013년까지 화재발생 추이에 대한 시계열분석과 Moran's I, Getis-Ord $Gi^*$분석을 통하여 진주시 공간상의 화재발생 밀도변화분석과 시설물별 화재위험도를 산출하였다. 그 결과 화재발생위치의 시계열적 변화와 화재발생 밀집도가 높은 Hot Spot지역을 추출할 수 있었으며, 시설물별 인명피해 및 재산피해 매트릭스를 작성하여 화재위험등급을 산출함으로서 도시지역의 화재발생위험을 예측할 수 있는 방안을 제시하였다.

위험도 정보 활용을 위한 화재 PSA 방법론 개선 연구 현황 (Present Status of Fire PSA Methodology for Risk-Informed Application)

  • 이윤환;양준언
    • 한국화재소방학회논문지
    • /
    • 제17권1호
    • /
    • pp.40-45
    • /
    • 2003
  • 본 논문에서는 현재 세계적으로 사용되고 있는 화재 PSA 방법론을 살펴보고 화재방호를 목적으로 위험도 정보를 이용할 시 요구되는 방법론의 개선 사항을 파악하였다. 화재 PSA의 결과 및 이를 통한 통찰(insight)은 의사 결정을 하는데 완전한 기술적인 근거라 하기보다는 위험도 정보를 활용한 의사 결정 과정의 일부로서 사용될 수 있으며, 화재 PSA 결과의 적용 분야와 적용 수준은 PSA에서 사용된 모델의 정확성과 타당성에 좌우된다고 할 수 있다. 따라서 화재 PSA의 유용성은 많은 분야의 연구와 개발을 통해 현재 기술 수준 증진에 따라 확대될 것이며, 그에 따라 더 일관성 있는 결과를 낳게 될 것으로 판단한다.