• Title/Summary/Keyword: fire risk

Search Result 1,159, Processing Time 0.027 seconds

Real-time Reagent Management System Using NFC / Sensor (NFC/센서를 이용한 실시간 시약 관리 시스템)

  • Kim, Ho-Sung;Jang, Jae-Myung;Jung, Hoe-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.421-426
    • /
    • 2016
  • Recent developments in internet technologies has enabled widespread growth of embedded systems like Arduino, Raspberry Pi and other smart home systems. A research in the industrial sector on the utilization of the board has been made. The development needs of the embedded board in a reagent bottle case system has been highlighted. Current reagent Management System has to hold and manage the reagent itself is mostly to save the program using handwritten or machine. In addition, there is a risk to the system during the vulnerable zone administrator to manage the situation of the reagent bottle case can lead to a massive fire. In this paper, reagent bottle case RFID readers and data in real-time is monitored by attaching a sensor management through the database and sends a warning message to the mobile device of the administrator in real time during hazardous situations in the reagent bottle case. This is improve the reliability and efficiency of reagent bottle case.

A Trends Analysis on Safety for CNG/HCNG Complex Fueling Station (CNG/HCNG 복합충전소의 안전에 관한 동향분석)

  • Lee, Seung-Hyun;Kang, Seung-Kyu;Sung, Jong-Gyu;Lee, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • In this research, the safety trends and technologies of HCNG, a mixture of hydrogen and natural gas, are analyzed. This is an attracting alternative fuels to meet the strengthened automotive exhaust gas emission standards. HCNG is very important opportunities and challenges in that it is available the existing CNG infrastructures, meets the strengthened emission standards, and the technical, social bridge of the coming era of hydrogen. It is essential for the commercialization of HCNG that hydrogen - compressed natural gas blended fuel for use in preparation of various safety considerations included accidents scenario, safety distance, hydrogen attack, ignition sources and fire detectors are examined. Risk assessments also are suggested as one of permission procedure for HCNG filling station.

A Study on the Physical and Chemical Characteristics and Hazards Buthanethiol (Buthanethiol의 물리화학적 특성과 유해성 연구)

  • Kim, Hyeon-Yeong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.9-17
    • /
    • 2013
  • Butanethiol is known as a typical odorant with hydrogen sulfide, methyl mercaptan, methyl sulfide, but on the physical and chemical properties and biological hazard assessment, including inhalation toxicity data are very scarce. Butanethiol as a colorless transparent liquid, and has physic-chemical characteristics with flash point as $-23^{\circ}C$ and strong fire risk, boiling point $84-85^{\circ}C$, vapor pressure 80.71 mmHg ($25^{\circ}C$), freezing point $-140.14^{\circ}C$. From whole body exposure with SD rats, the $LC_{50}$ is above 2,500 ppm (9.22mg/L), and then it is classified as the acute toxic chemical (inhalation) category 4 according to the governmental notification No. 2012-14.

A Study on Performance Evaluation and Security Measures of U-IT Electrical Safety Integrated Management System's Module (U-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dea-Woo;Choi, Choung-Moon;Kim, Eung-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.307-310
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. U-City in order to prevent the disaster of U-IT Power Equipment Performance Module and the security for the safety of the U-City is necessary. In this paper, the power unit of U-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation and security measures will be studied. U-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as U-IT integrated management system for electrical safety and strengthen the security, safety and security with a U-City will contribute to the construction and operation.

  • PDF

AE Characteristic under Tensile of Carbon Steel for High-Pressure Pipe (고압배관용 탄소강의 인장시 음향방출 특성)

  • Nam Kiwoo;Lee Siyoon
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.48-53
    • /
    • 2003
  • This study is to look at the effect for deformation of carbon steel for high-presure pipe, on the AE signals produced by tensile test. Acoustic emission(AE) has been widely used in various fields because of its extreme sensitivity, dynamic detection ability and location of growing defects. We investigated a relationship failure mode and AE signals by tensile test, From the tensile test, we could divide into four ranges of the failure modes of elastic range, yield range, plastic range before $\sigma$u, plastic range after $\sigma$u. And failure behaviors of elastic range, yield range, plastic range before $\sigma$u, plastic range after $\sigma$u could be evaluated in tensile test by AE counts, accumulation counts and time frequency analysis. It is expected to be basic data that can protect a risk according to tensile test and bending of pipe material for pressure vessel, as a real time test of AE.

  • PDF

A Study on Development of Root Cause Analysis Map In Laboratory (연구 실험실 사고의 근본원인분석 Map 개발에 관한 연구)

  • Eom, Seok-Hwa;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.6-11
    • /
    • 2010
  • The continuous fatal accidents like explosion or fire cause huge losses of both life and property in laboratories even though safety management system has been built and periodical checkups and safety diagnosis have been implementing in universities and enterprise-affiliated research institutes since Act on the Establishment of Safe Laboratory Environment was enacted in 2005 to prevent accidents in research laboratories. Cause analysis and safety management measures to prevent recurrence of accidents are urgently needed because accidents in research laboratories occur repeatedly with similar contents. This study will show results of analysis on incidents and accidents occurred in laboratories in universities and enterprise-affiliated research institutes using Root Cause Analysis Method and propose classified map of cause investigation and improvements so as to improve safety management in research laboratories.

A Study on Analysis of Laboratory Accident with Root Cause Analysis (근본원인분석 기법을 활용한 실험실 사고 분석에 관한 연구)

  • Eom, Seok-Hwa;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.1-5
    • /
    • 2010
  • Many sorts of fatal accidents like explosion or fire caused by gas leakage have become a social issue with the increasing use of harmful chemicals in laboratories in universities and enterprise-affiliated research institutes in Korea. Importance of safety management has been emphasized and it made Act on the Establishment of Safe Laboratory Environment enacted not only to protect lives and bodies of people working in laboratories in universities and enterprise-affiliated research institutes but also to make pleasant experimental atmosphere. Safety management system has been built and periodical checkups and safety diagnosis have been implementing in universities and enterprise-affiliated research institutes to prevent such accidents. However, in spite of those actions, continuous accidents make analysis of root cause essential. This study will show results of analysis on incidents and accidents occurred in laboratories in universities and enterprise-affiliated research institutes using Root Cause Analysis Method and propose the direction of safety management.

Radiological Safety Assessment of Transporting Radioactive Wastes to the Gyeongju Disposal Facility in Korea

  • Jeong, Jongtae;Baik, Min Hoon;Kang, Mun Ja;Ahn, Hong-Joo;Hwang, Doo-Seong;Hong, Dae Seok;Jeong, Yong-Hwan;Kim, Kyungsu
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1368-1375
    • /
    • 2016
  • A radiological safety assessment study was performed for the transportation of low level radioactive wastes which are temporarily stored in Korea Atomic Energy Research Institute (KAERI), Daejeon, Korea. We considered two kinds of wastes: (1) operation wastes generated from the routine operation of facilities; and (2) decommissioning wastes generated from the decommissioning of a research reactor in KAERI. The important part of the radiological safety assessment is related to the exposure dose assessment for the incidentfree (normal) transportation of wastes, i.e., the radiation exposure of transport personnel, radiation workers for loading and unloading of radioactive waste drums, and the general public. The effective doses were estimated based on the detailed information on the transportation plan and on the radiological characteristics of waste packages. We also estimated radiological risks and the effective doses for the general public resulting from accidents such as an impact and a fire caused by the impact during the transportation. According to the results, the effective doses for transport personnel, radiation workers, and the general public are far below the regulatory limits. Therefore, we can secure safety from the viewpoint of radiological safety for all situations during the transportation of radioactive wastes which have been stored temporarily in KAERI.

Recommendation of an Occupational Exposure Limit and Legal Control Following an Acute Hepatotoxicity Incident from HCFC-123 (HCFC-123의 급성 독성간질환 발생 사례에 따른 노출기준 및 법 관리 필요성 권고)

  • Lee, Kwon Seob;Jo, Ji hoon;Choi, Bo Kyung;Lee, Hye Lim;Byeon, Sang Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.80-90
    • /
    • 2018
  • Objectives: This study was performed to propose a domestic occupational exposure limit(OEL) following a health hazard assessment, calculation of a non-carcinogenicity reference concentration worker($RfC_{worker}$) value, and examination of international agencies' exposure limits. It also recommends legal management within the Occupational Safety and Health Act for HCFC-123, which caused an acute hepatotoxicity incident. Methods: An acute hepatotoxicity incident due to the fire extinguishing agent HCFC-123 was investigated. Toxicological hazard and health hazard classifications were examined and a non-carcinogenicity $RfC_{worker}$ value was calculated for HCFC-123. An OEL and the necessity of legal management were recommended as well. Results and Conclusions: An OEL for HCFC-123 of 10 ppm($62.5mg/m^3$), which considered the $RfC_{worker}$ value, 5.56 ppm, produced in dose-response assessment and the exposure level of 19.1-20.9 ppm measured as an eight-hour TWA(time-weighted average) in the incident place, is recommended. HCFC-123 is urged to be included as a chemical requiring legal management in the Occupational Safety and Health Regulations. In addition, it is recommended that a peak exposure of ACGIH be adopted in the Notice of the Ministry of Employment and Labor.

A Plan for Construction of the National Electrical Safety Grid to Prevent the Fires Caused by Electrical Faults (전기화재 예방을 위한 국가전기안전망 구축 방안)

  • Bae, Seok-Myeong;Jeon, Jeong-Chay;Park, Chan-Eom;Bae, Seok-Myeong;Ko, Won-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2267-2273
    • /
    • 2009
  • In this paper, in order to monitor and manage an electrical risk factor like as leakage current, load current, and arc-fault, a real time monitoring and management system being operated in the ubiquitous environment was developed, and a plan of construction of an electrical safety grid using the system was proposed. For confirmation of usefulness and reliability of the proposed safety system and grid, the developed intelligent panels were applied to 28 Korean traditional houses in Jeonjoo city, and the grid including the panels was operated. If the proposed National Electrical Safety Grid is completely constructed in the houses of general electrical users, the Grid will have an effect on that a main manager on electrical safety transfers from management system by general people to real-time management system by expert. As a result, the electrical fires caused by an over-load, an arc-fault, and an earth-fault will be prevented.