• Title/Summary/Keyword: fire period

Search Result 432, Processing Time 0.026 seconds

A Combustion Characteristic Analysis of PMMA by Cone Heater of the flexible Heat Flux (콘 히터의 유동적인 열선속을 적용한 PMMA의 연소 특성 분석)

  • Moon, Sung-Woong;Ryu, Sang-Hoon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.39-44
    • /
    • 2010
  • The cone calorimeter method which is currently used to measure the heat release rate has a fixed rate of radiation. However, in the real fire, when flame combustible material burns, it releases the identical heat flux. We measured the changes of temperature of a fire using FDS in order to analyze flexible heat flux of combustion characteristics. In this study, the rate of radiation of cone calorimeter was adopted by using FDS. Follow those results, it produce between the rate of radiation in the growth period and decline period have a significant impact on heat release rate of PMMA.

A Study on the Performance Variation Depending on Using Period of Ionization Smoke Detector (이온화식연기감지기의 사용기간 경과에 따른 성능변화 연구)

  • Kim, Shi-Kuk;Baek, Won-Don;Ok, Kyung-Jea;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.175-179
    • /
    • 2008
  • This paper studied on the performance variation depending on using period of ionization smoke detector. In korea, there were a lot of loss of lives and property because of fire. In many cases, an alarm equipment didn't operate though it was set up, so it causes the failure of early evacuation and fire suppression. Accordingly, an experiment on the change of ionization smoke detector in capacity performed with ionization smoke detector which is set up with fire objects.

  • PDF

A Numerical Study of the Effect off Fire Growth Model on Fire Characteristics in a Carriage (화재 성장 모델이 객차내 화재 특성에 미치는 영향에 관한 수치해석적 연구)

  • 김성찬;유홍선;최영기;김동현
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.3
    • /
    • pp.180-185
    • /
    • 2004
  • The present study investigates the effect of fire growth model on fire development characteristics in a carriage. The parallel processing version of FDS code is used to simulate the fire driven flow in a carriage and two types of fire growth model which are flame spread model and t$^2$ model are examined for the same geometrical condition. The heat release rates(HRR) of both model are similar each other until 30 s after ignition, but the flame spread model predicts 5 times higher than those of the t$^2$ fire model during the quasi-steady fire period. Maximum heat release rate in the case of flame spread model reaches about to 12 MW at 100 s after fire ignition. Also, various database of fire properties for combustible materials and more elaborate combustion model considering the flame spreading phenomena are required for better predictions of fire development characteristics using numerical simulation.

Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period (경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석)

  • Kim, Min Ho;Lee, Seok Hui;Lee, Min Chul;Lee, Sang Kyu;Lee, Ju Eun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

Firefighters' Exposure to Volatile Organic Compounds in Tyre Fire (타이어 화재 대응 소방관들의 휘발성유기화합물 노출 평가)

  • Won Kim;Inja Choi;Young-Hwan Cho;Hye-young Jung;Jiwoon Kwon;So-Yun Lee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.385-394
    • /
    • 2023
  • Objectives: Firefighters could be exposed to a range of toxic chemicals during firefighting. When tyre burns, various toxic chemicals including volatile organic compounds(VOCs) could be emitted. In this study, the researchers assessed the VOC exposure of firefighters during tyre fire suppression through biomonitoring. Methods: There was a big tyre fire on 12 March 2023. Of the responding firefighters, we recruited 14 participants to collect their urine after firefighting. One week later, researchers collected firefighters' urine again right after their off-duty period. We analyzed each metabolite of benzene, toluene, xylene, and styrene in urine and compared their exposure level based on sampling time. Results: The detection rate for metabolite of benzene, toluene, styrene, and xylene in urine sampled at each time was 43%-64%, 100%, 86%-100%, and 100%, respectively. Except for the benzene, metabolite levels measured in urine after firefighting were similar to that from off-duty period. However, the median concentration of benzene metabolite in urine sampled after firefighting was three times higher compared to that from off-duty period(34.2 ㎍/g crea. and 10.9 ㎍/g crea., respectively.) The estimated airborne concentration of benzene calculated from metabolite level in urine was 0.16 ppm, which exceeded the recommended exposure level set by the National Institute for Occupational Safety and Health. Conclusions: This study shows that firefighters could be exposed to the high level of VOCs including benzene during their firefighting especially at tyre fire. These results could be used as a valuable data to prove firefighters' exposure to hazardous chemicals during their duty.

Fire Simulations (화재시뮬레이션)

  • Kim Sang-Moon;Yoon Sang-Youl;Kim Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.1
    • /
    • pp.8-13
    • /
    • 2006
  • Fire simulation has been developed for decades to analyze fire cases and provide a tool to study fundamental fire dynamics and combustion. There are three way of fire simulation which are a full scale simulation, an experimental simulation and a computational simulation. In case of a full scale simulation, because a higher cost, a higher risk, more efforts are needed, a demand for it has been decreased. But recently a demand for an experimental simulation and a computational simulation has been increased. A computational simulation has several advantages; lower cost, short period, many case studies, more visual results, a quantitative result and etc. FDS(Fire Dynamics Simulator) which has been developed in BFRL(Building and Fire Research Laboratory), NIST(National Institute of Standards and Technology) is a popular world wide code for fire simulation. Lack of accurate predictions by the model could lead to erroneous conclusions with regard to fire safety. All results should be evaluated by the informed judgment of the qualified user.

  • PDF

An Experimental Study on the Formation of Smoke Layer of Compartment Fire (건물화재시 연기층의 형성에 관한 실험적연구)

  • 허만성
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.94-100
    • /
    • 1997
  • The objective of this research is to study the formations of smoke layer in case of several furniture fires such as trashcan, carpet, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The uniformly distributed fire in case of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as the trashcan, mattress and wardrobe showed that the ignitions and the initial growth periods were relatively long. The descending speed of the interface height was proportioned to the inflammability of the furniture and the spread of the fire. The time required to come down around 1m was within 1-3 minutes. The Interface heights for the furniture fires were around 1m as the steady state. However, at the time of the maximum temperature, the interface height was lowered to 0.25m-0.75m from the floor. The carbon dioxide concentration reached the highest while the oxygen concentration was minimum.

  • PDF

A Study on Properties of Hardboard from Japanese Larch Killed by Fire (일본잎갈나무 산화(山火) 고사목(枯死木)을 원료(原料)로 한 하드보드 재질연구(材質硏究))

  • Jun, Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.31-35
    • /
    • 1981
  • This study was carried out to investigate the properties of hardboard made from fire killed larch tree and also effects of standing period after killed by fire. The results are as follows; 1. There were no effects on hardboard properties among the standing period differences after killed by fire within about 2 years. 2. Specific gravities, moisture contents, water absorptions of the boards from dead trees have no differences compared with those of sound wood. 3. Bending strengths of the boards from dead trees we re decreased in the range of 24-28% of the boards from sound wood.

  • PDF

Evaluation of Fire Characteristics for Particle-board with Exfoliated Graphite Nanoplatelets Added (탄소재료의 적용 방법에 따른 파티클 보드의 연소 특성)

  • Seo, Hyun Jeong;Jo, Jeong Min;Hwang, Wuk;Lee, Min Chul
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.4
    • /
    • pp.1-8
    • /
    • 2017
  • This study was conducted to evaluate the fire retardant performance of exfoliated graphite nanoplatelets (xGnP) applied for particleboard. This work measured heat release rate(HRR), total heat release(THR) and smoke production rate(SPR) of xGnP added particleboard, using cone calorimeter to assess its fire characteristics according to the KS F ISO 5660-1 standard code. Heat release rates of all specimens treated by xGnP were less than the $200kW/m^2$ for a total experiment period of five minutes. Heat release rates of the specimens coated with xGnP were lower than those of the specimens made by mixing wood particles with xGnP directly. Meanwhile, the total heat release rates of xGnP coated specimen maintained quite lower level than the uncoated so the xGnP coating were effective in improving the fire retardant performance of particleboard. However, the smoke emission peaking problem at the initial combustion period, which was caused by adding base coating materials, should be resolved for further satisfaction as a fire retardant materials.

A Study on the Imfluence of the Pipe Line of Boiler for Flame Distribution of Combustion Furnace (연소로의 화염분포가 보일러 관로에 미치는 영향에 관한 연구)

  • Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1435-1441
    • /
    • 2014
  • The fire took place in the synthetic heat transfer fluid boiler used in production process of medium density fiberboard. This study investigated pressure distribution of the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner. Pressure distribution at steady state in combustion furnace is 2~5mAq and pressure distribution at inverter under fault condition in combustion furnace is 10~-53mAq. The decrement of coil thickness measurement for synthetic heat transfer fluid boiler is 0~5mm.