• Title/Summary/Keyword: fire period

Search Result 432, Processing Time 0.02 seconds

Characteristics of Performance and Back-Fire for External Mixture Hydrogen Fueled Engine without Valve Overlap Period (밸브 오버랩 기간이 없는 흡기관 분사식 수소기관의 성능 및 역화특성)

  • Lee, K.J.;Kang, J.K.;Cong, Huynh Thanh;Noh, K.C.;Lee, J.T.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.4
    • /
    • pp.374-381
    • /
    • 2007
  • In order to verify the feasibility of expansion of back-fire limit equivalence ratio in the hydrogen-fueled engine with external mixture, the characteristics of performance and combustion are experimentally analyzed with change of intake/exhaust valve timings under the fixed valve overlap period of $0^{\circ}$ CA(non-valve overlap period). These characteristics are also tested for the change of exhaust valve closing timing while intake valve opening timing is fixed to clear the main cause of back-fire occurrence. As the results, the less valve overlap period center is retarded, the more back-fire limit equivalence ratio increases and back-fire does not occurred after TDC. In addition, it was shown that the control of back-fire is dependent on intake valve opening timing than valve overlap period.

A Investigation of Back Fire Control with Valve Overlap Period Change In the Same Supply Energy (동일열량공급하의 밸브오버랩기간 변화에 대한 역화억제 검토)

  • Kang, J.K.;Huynh, Thanh Cong;Noh, K.C.;Lee, J.T.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.3
    • /
    • pp.348-355
    • /
    • 2007
  • To grasp a feasibility of back fire control by valve overlap period, back fire limit equivalence ratio was estimated with valve overlap period which has the same supply energy and positive intake pressure as valve overlap period $300^{\circ}\;CA$. As the result, it was shown that the smaller valve overlap period has the higher back fire limit equivalence ratio under valve overlap period $300^{\circ}\;CA$ as well as VOP $0^{\circ}\;CA$. This result means that expansion of back fire equivalence ratio by decreasing valve overlap period was caused by decrease of back flow duration of flame from in-cylinder to intake port than decrease of lower supply energy.

Analysis of the Relationship between the Number of Forest Fires and Non-Rainfall Days during the 30-year in South Korea

  • Songhee, Han;Heemun, Chae
    • Journal of Forest and Environmental Science
    • /
    • v.38 no.4
    • /
    • pp.219-228
    • /
    • 2022
  • This study examined the relationship between the number of forest fires and days with no rainfall based on the national forest fire statistics data of the Korea Forest Service and meteorological data from the Open MET Data Portal of the Korea Meteorological Administration (KMA; data.kma.go.kr) for the last 30 years (1991-2021). As for the trend in precipitation amount and non-rainfall days, the rainfall and the days with rainfall decreased in 2010 compared to those in 1990s. In terms of the number of forest fires that occurred in February-May accounted for 75% of the total number of forest fires, followed by 29% in April and 25% in March. In 2000s, the total number of forest fires was 5,226, indicating the highest forest fire activity. To analyze the relationship between regional distribution of non-rainfall periods (days) and number of forest fires, the non-rainfall period was categorized into five groups (0 days, 1-10 days, 11-20 days, 21-30 days, and 31 days or longer). During the spring fire danger season, the number of forest fires was the largest when the non-rainfall period was 11-20 days; during the autumn fire precaution period, the number of forest fires was the largest when the non-rainfall period was 1-10 days, 11-20 days, and 21-30 days, showing differences in the duration of forest fire occurrence by region. The 30-year trend indicated that large forest fires occurred only between February and May, and in terms of the relationship with the non-rainfall period groups, large fires occurred when the non-rainfall period was 1-10 days. This signifies that in spring season, the dry period continued throughout the country, indicating that even a short duration of consecutive non-rainfall days poses a high risk of large forest fires.

The Analysis on Forest Fire Occurrence Characteristics by Regional Area in Korea from 1990 to 2014 Year

  • Jeon, Bo Ram;Chae, Hee Mun
    • Journal of Forest and Environmental Science
    • /
    • v.32 no.2
    • /
    • pp.149-157
    • /
    • 2016
  • Understanding regional characteristics in forest fire occurrence is important to establish effective forest fire prevention policy in Korea. This study analyzed the characteristics of forest fires occurred in 16 administrative districts for recent 25 years (1990~2014) to examine regional characteristics in forest fire occurrence. Forest fire occurrence reflects regional characteristics depending on climatic factors as well as region's society-cultural factors. Results showed that the first cause of forest fire occurrence was carelessness by human activities throughout all administrative districts, however, the second cause depends on regional characteristics. As the results of forest fire occurrence period analyzed for 10 days, the most forest fires occurred in the southern region during January to March, while forest fires in the northern region occurred mostly during March to April. We classified forest fire occurrence patterns into three types (centralized: Gyeonggi-do, dispersal: Busan, horizontally distributed: Gyeongsangnam-do) by multi-temporal analysis for forest fire occurrence period.

A Study on the Safety and Health Consciousness for the Working Environment of Fire Fighter (소방공무원 근무환경에 대한 안전보건 의식 연구)

  • Lee, Jong-Ho;Kim, Yo-Han
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.137-143
    • /
    • 2015
  • Fire fighter are exposed to the situations which are hard to predict due to continuous and accidental changes which hinder their fire fighting activity. As these threats of safety accident act as fear factors, they are doing insecure fire fighting activities. Therefore, as unclear and abnormal risks of working environment such as the riskiness of expansion of disaster, instability, obstacles of activities, abnormality, urgency, etc. increase, safety accidents are caused. This study analyzes the actual condition of safety and health and awareness of fire fighter who are exposed safety accidents during their fire fighting activities and utilize such result as the basis data to secure safety of fire fighter, keep efficient safety control and prevent accidents. The results of analysis are as follows. As rescue works among all fire-fighting works shows the highest emotional stabilization and the highest post-traumatic stress disorder is shown in fire sergeant level positions, and fire fighters whose working period is 10-15 years, reinforcing safety training to long-term workers is necessary. As the result of survey regarding safety awareness, the highest awareness level was shown in fire sergeant level positions, and fire fighters whose working period is over 20 years, and when it comes to operation of fire fighting equipments, fire-fighting workers and workers having 1-4 years of working period showed high safety awareness. The more serious injury in a fire fighter experienced as the first injury after working as a fire-fighter, the more cause-and-effect relationship was shown between personal physical condition and work, and it is shown as obstacles of fire fighting activities and affects to post-traumatic stress disorder. Moreover, as after-work off duty activities also affect to official disaster, systematic improvement of working environment is required. Occupational medical work compatibility evaluation considering the distinct characteristics of works to secure fire-fighter' health care together with fire-fighting capability is shown to be necessary.

AN EXPERIMENTAL STUDY ON THE FORMATION OF SMOKE LAYER IN COMPARTMENT FIRE

  • Hur, Man-Sung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.477-483
    • /
    • 1997
  • Experiments have been performed to investigate the formation of smoke layer in case of several furniture fires such as trashcan, chair, carpet, sofa, mattress, and wardrobe in a residential room. As a result of the present investigation, the uniformly distributed fire of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as mattress and wardrobe showed that the ignition and the initial growth period were relatively long. The descending time of the interface heights was within 1-3 minutes to reach around 1m. However, the interface height was lowered to 0.25-0.75m above the floor at the time of the maximum temperature.

  • PDF

A Study on the Formations of Thermal Stratification of Furniture Fire (가구화재시 열적성층의 형성에 관한 연구)

  • 허만성
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.24-29
    • /
    • 1996
  • The objective of this research is to study on the formations of thermal stratification in a room in case of several furniture fires such as trashcan, chair, carpet, sofa, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The uniformly distributed fire in case of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as the mattress and wardrobe showed that the ignitions and the initial growth periods were relatively long. When fire spread to only one direction, like the case for the trashcan with a regular shape, there was one peak of temperature profile, and for the irregular shaped furniture such as chair, sofa, mattress and wardrobe, there were two or more peaks. The interface heights for the furniture fires were around 1(m) mataining constant state. However, at the time of the maximum temperature, the interface height was lowered to 0.25(m)-0.75(m) from the floor

  • PDF

A Study on the Fire Resisting Properties of Reinforced Concrete Structures (철근콘크리트 구조물의 내화성능에 관한 연구)

  • 김무한;송하영
    • Fire Science and Engineering
    • /
    • v.2 no.1
    • /
    • pp.3-10
    • /
    • 1988
  • Concrete is incombustible and has good fire resisting properties, i. e. when exposed to fire it continues to perform satisfactorily for a reasonable period of time. Nevertheless, with time and high temperature gradient, brought about the fire, causes cracking and spatting. Further deterioration and loss of strength are caused by gradual dehydration of concrete paste. This paper is aimed to make a proposal for the design and construction of reinforced concrete structures with more sufficent resistance to fire by the theoritical analysis, which is base4 on investigation of general damages by the fire and change of properties on concrete influenced by high temperature.

  • PDF

Statistical Analysis on Danger Period of Forest Fire by Regions in Korean (통계분석을 이용한 지역별 산불위험시기 구분)

  • Kim, Sun-Young;Lee, Si-Young;An, Sang-Hyun;Shin, Young-Chul;Oh, Jeong-Soo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.161-167
    • /
    • 2002
  • Forest fire danger period in nine Provinces (Gangwondo, Kyonggido, Gyeongsangnamdo, Gyeongsangbukdo, Jeollanamdo, Jeollabukdo, Jejudo, Chungcheongnamdo, Chungcheongbukdo) has turned out to be similar to recognize whether there are some differences between each Provinces, we used correlation analysis with number of occurrence and damage area by an interval of ten-day period. Based on this analysis, there was significant numbers of occurrence at all areas wish serious burns except Gyeongsangnamdo and Jejudo Provinces. Since persuasive power is insufficient as danger period of forest fire applies equally to nine Provinces, statistical analysis using number of forest fire occurrence and burned area are executed. And then, a analysis of variance(ANOVA) test of significance by an interval of ten day period is carried out. As a result of this analysis, there showed significant at 1% level for number of occurrence except Jejudo, and is also showed significant at 1% level for burned area except Gangwondo and Chejudo. Through regional correlation analysis for danger period, we classified three parts of Middle region (Gangwondo, Kyonggido, Gyeongsangnamdo, Gyeongsangbukdo, Jeollabukdo, Chungcheongnamdo, Chungcheongbukdo) Southern region (Gyongsangnamdo, Jeollanamdo) and Jejudo region. With respect to forest fire occurrence time, Middle region showed from the middle of February to first of May that amounts to 81% of entire occurrence in this region, and Southern region begins with at the last of January to the middle of April covering 71%. In terms of forest fire burned areas, it appears at the middle of February to the first of May, occupying 98% in Middle region, and Southern region showed burned areas from the last of January to the middle of April amounting to 82% of total occurrences.