• 제목/요약/키워드: fire load test

검색결과 160건 처리시간 0.023초

The bearing capacity of monolithic composite beams with laminated slab throughout fire process

  • Lyu, Junli;Zhou, Shengnan;Chen, Qichao;Wang, Yong
    • Steel and Composite Structures
    • /
    • 제38권1호
    • /
    • pp.87-102
    • /
    • 2021
  • To investigate the failure form, bending stiffness, and residual bearing capacity of monolithic composite beams with laminated slab throughout the fire process, fire tests of four monolithic composite beams with laminated slab were performed under constant load and temperature increase. Different factors such as post-pouring layer thickness, lap length of the prefabricated bottom slab, and stud spacing were considered in the fire test. The test results demonstrate that, under the same fire time and external load, the post-pouring layer thickness and stud spacing are important parameters that affect the fire resistance of monolithic composite beams with laminated slab. Similarly, the post-pouring layer thickness and stud spacing are the predominant factors affecting the bending stiffness of monolithic composite beams with laminated slab after fire exposure. The failure forms of monolithic composite beams with laminated slab after the fire are approximately the same as those at room temperature. In both cases, the beams underwent bending failure. However, after exposure to the high-temperature fire, cracks appeared earlier in the monolithic composite beams with laminated slab, and both the residual bearing capacity and bending stiffness were reduced by varying degrees. In this test, the bending bearing capacity and ductility of monolithic composite beams with laminated slab after fire exposure were reduced by 23.3% and 55.4%, respectively, compared with those tested at room temperature. Calculation methods for the residual bearing capacity and bending stiffness of monolithic composite beams with laminated slab in and after the fire are proposed, which demonstrated good accuracy.

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • 제8권6호
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

온도해석과 재하가열시험에 의한 콘크리트 충전 보부재의 내화성능평가에 관한 연구 (Study on Fire Resistance of Beams filled with Concrete at Web Through Temperature Analysis and Load-bearing Fire Tests)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.82-88
    • /
    • 2010
  • 건축 구조물의 주요 구조부는 중력하중의 전달과 수평하중을 견디도록 설계, 시공되어야 함을 물론이고, 화재의 고열환경에서 부수적으로 발생되는 온도에 의한 추가하중을 지지하도록 설계되어야 한다. 강구조 건축물에서의 보부재는 중력 및 횡력 방향의 하중에 더 강한 지지력을 확보하기 위하여 H형강 웨브부분에 콘크리트를 충전하는 타입의 개발 및 적용이 이루어져 왔으나, 내화성능의 평가는 거의 이루어지지 않은 상태이다. 따라서 본 논문에서는 H형강 보부재의 웨브에 일반강도의 콘크리트로 충전된 시험체를 대상으로 열전도 해석에 의한 내화성능과 재하가열시험을 통한 내화성능을 각각 제시하고 상관성을 비교분석하였다.

일정 축력을 받는 Double CFT기둥의 내화성능 평가 (Fire Resistance of Concrete Filled Double Skin Tubular Columns under Axial Load)

  • 정상근;김선희;이성희;최성모
    • 한국강구조학회 논문집
    • /
    • 제23권1호
    • /
    • pp.51-59
    • /
    • 2011
  • 높은 축력비가 적용된 무피복 CFT기둥은 보통 중저층 건물에서 2시간 이하의 내화성능을 확보하는데 적용 가능하나, 고층건물에서 요구되는 3시간의 내화성능을 만족시키지는 못한다. 따라서 고층건물에 무피복 CFT기둥을 적용하기 위해서는 추가적인 내화성능 향상방안이 제시되어야 한다. 이에 본 연구에서는 무피복 CFT기둥의 내화성능 향상방안으로써 Double CFT기둥을 설정하였다. 본 연구에서는 실대크기의 무피복 CFT기둥과 Double CFT기둥에 대한 재하가열실험을 수행하였다. 이를 통해, Double CFT기둥의 적용에 따른 내화성능 향상 효과 및 강관의 단면형상 변화에 따른 영향을 비교 평가해 보고자 한다.

룸 코너 콘 칼로리미터 시험(ISO 9705)과 비교를 통한 FDS 열분해 모델의 신뢰성 분석 (A Reliability Analysis on FDS Pyrolysis Model through Comparing the Room-Corner (ISO 9705) Test)

  • 양성진;이창덕;오지은;강찬용;김학범;이덕희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.585-593
    • /
    • 2011
  • Actual fire test under a laboratory and fire simulation by using computer are considered into main methodology in order to estimate and predict fire size of railway train. Even if practical fire size could be obtained from the full-model railway car test such as a large scale cone-calorimeter test, it is not always possible and realistic due to that expensive cost and attendant dangers could in no way be negligible. In this point of view, fire simulation analysis method based on the computational fluid dynamics could be proposed as an alternative and it seems to be also efficient and reasonable. However, simulation results have to be verified and validated in accordance with the proper procedure including comparing analysis with the actual fire test. In this paper, fire load and growth aspect was investigated through the room corner test (ISO 9705) for the mock-up model of the actual railway car. Then, it was compared with the output data derived from the simulation by using Pyrolysis Model of the FDS (Fire Dynamics Simulator, by NIST) for the exact same domain and condition corresponding with pre-performed room-corner test. This preliminary verified and validated fire modeling method could enhance the reliability of output data derived from the fire simulation under the similar domain and condition.

  • PDF

Behaviour of ultra-high strength concrete encased steel columns subject to ISO-834 fire

  • Du, Yong;Zhou, Huikai;Jiang, Jian;Liew, J.Y. Richard
    • Steel and Composite Structures
    • /
    • 제38권2호
    • /
    • pp.121-139
    • /
    • 2021
  • Ultra-high strength concrete (UHSC) encased steel columns are receiving growing interest in high-rise buildings owing to their economic and architectural advantages. However, UHSC encased steel columns are not covered by the modern fire safety design code. A total of 14 fire tests are conducted on UHSC (120 MPa) encased steel columns under constant axial loads and exposed to ISO-834 standard fire. The effect of load ratio, slenderness, stirrup spacing, cross-section size and concrete cover to core steel on the fire resistance and failure mode of the specimens are investigated. The applicability of the tabulated method in EC4 (EN 1994-1-2-2005) and regression formula in Chinese code (DBJ/T 15-81-2011) to fire resistance of UHSC encased steel columns are checked. Generally, the test results reveal that the vertical displacement-heating time curves can be divided into two phases, i.e. thermal expansion and shortening to failure. It is found that the fire resistance of column specimens increases with the increase of the cross-section size and concrete cover to core steel, but decreases with the increase of the load ratio and slenderness. The EC4 method overestimates the fire resistance up to 186% (220 min), while the Chinese code underestimates it down to 49%. The Chinese code has a better agreement than EC4 with the test results since the former considers the effect of the load ratio, slenderness, cross section size directly in its empirical formula. To estimate the fire resistance precisely can improve the economy of structural fire design of ultra-high strength concrete encased steel columns.

Large scale fire test on a composite slim-floor system

  • Bailey, C.G.
    • Steel and Composite Structures
    • /
    • 제3권3호
    • /
    • pp.153-168
    • /
    • 2003
  • This paper discusses the results and observations from a large-scale fire test conducted on a slim floor system, comprising asymmetric beams, rectangular hollow section beams and a composite floor slab. The structure was subjected to a fire where the fire load (combustible material) was higher that that found in typical office buildings and the ventilation area was artificially controlled during the test. Although the fire behaviour was not realistic it was designed to follow as closely as possible the time-temperature response used in standard fire tests, which are used to assess individual structural members and forms the bases of current fire design methods. The presented test results are limited, due to the malfunction of the instrumentation measuring the atmosphere and member temperatures. The lack of test data hinders the presentation of definitive conclusions. However, the available data, together with observations from the test, provides for the first time a useful insight into the behaviour of the slim floor system in its entirety. Analysis of the test results show that the behaviour of the beam-to-column connections had a significant impact on the overall structural response of the system, particularly when the end-plate of one of the connections fractured, during the fire.

내화피복 종류에 따른 각형 CFT기둥의 온도분포에 관한 실험적 연구 (An Experimental Study on the Temperature Distribution of Square CFT Columns According to the Types of Fire Protection)

  • 김해수;이치형
    • 한국강구조학회 논문집
    • /
    • 제22권6호
    • /
    • pp.523-532
    • /
    • 2010
  • 콘크리트가 충전된 각형강관기둥(이하, 각형 CFT기둥)은 높은 내화성능과 하중저항능력을 보유하고 있지만, CFT기둥의 외부에 내화피복을 함으로써 기둥의 내화성능을 향상시킬 필요가 있다. 본 연구는 내화 피복된 각형 CFT기둥의 온도분포에 대한 실험결과이다. 실험을 위하여 특수 제작된 전기로를 이용하여 축소모형 시험체의 재하가열실험을 수행하였다. 축하중을 받는 내화 피복된 각형 CFT기둥의 온도 분포 특성을 파악하기 위하여 내화피복의 종류와 두께, 강관의 두께 및 가열시간 등을 변수로 설정하였다. 실험결과 전기로의 온도에 따른 시험체별 온도분포와 콘크리트와 강재의 온도분포 특성을 파악하였다. 또한 시험체의 온도변화에 따른 축변위와 국부좌굴 등의 거동을 파악하였다.

뿜칠피복 각형 강관의 내화성능 평가를 위한 실험적 연구 (An Experimental Study on the Evaluation of the Fire-Resistance Performance of a Spray-Applied Rectangular Steel Structure)

  • 옥치열;김재준
    • 한국공간구조학회논문집
    • /
    • 제17권1호
    • /
    • pp.41-47
    • /
    • 2017
  • Structures of steel frame buildings getting vary depending on the development of construction technology. Fire-resistant steel beams and Columns accredited by accreditation bodies from the performance of various fire-resistant coating is applied to the current pillar method is most H-beams. H-beam has been proposed a non-load test specifications in the relevant regulations, its scope of accreditation to be granted without limitation of size H-beams from the performance of the test specification. However, in the case of the rectangular steel structure is to check its performance and to a separate one of the receive acknowledge and so take advantage of the cross-sectional shape factor in this study to test the performance of the fire-resistant structure proposed for standard test specimen.

강화액 소화성능평가에 관한 연구 (A Study on the Fire Extinguishing Ability Rating of Load Streams)

  • 권성필;김형권;윤헌주;사공성호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.159-162
    • /
    • 2008
  • A standard fire extinguishing tester, with which we could conduct the fire extinguishing ability rating of a water-based fire extinguishing agent such as water and loaded stream, has been developed in this work. It could help us enhancing the efficiency and reliability of the fire extinguishing test of loaded streams, and at last increasing the productivity of fire protection related firms. Furthermore, our country could take the lead in making a new standard for the fire extinguishing test of loaded streams. As a result, it is expected that loaded streams could be improved by using it. In addition the standard fire extinguishing tester could be made moderately in our industry, and supplied at home and worldwide.

  • PDF